Connext User Manual
Rev. 2.2 10/01/2023
Follow the instructions to connect the RS485 port to HYD-3000/3600/4000/5000/6000-ZSS -HP
inverters.
Figure 14
–
Preparing RS485 cables
1)
Remove a suitable length of the protective sleeve, as shown in the figure (A: 80~100 mm B:
6~8 mm).
2)
Connect the 2-
pole cable to the pins of the HP hybrid inverter marked “RS485”. Follow the
polarity shown in the figure and the pin-out in the table.
Figure 15 - Connections on HP single-phase hybrid inverter
RS485 Pin
24-pin terminal block
RS485 + (Red)/ 5
9
RS485
–
(Black)/ 6
10
Table 8 - RS485 connections to HP single-phase hybrid inverter
For connecting the RS485 port to HYD-3000/3600/4000/5000/6000-ZSS inverters, refer to Figure
17 on connecting to the inverter.