background image

 

Advanced

 

Miniature

 

CCD

 

Scan

 

Module

 

67

 

U

SER

S

 

M

ANUAL

 

 

Start

 

Of

 

Configuration

 

 

Full

 

ASCII

 

Code

 

39

 

Table

 

Code

 

39

 

ASCII

 

Hexa

code

Code

 

39

 

ASCII

 

Hexa

code

 

 

Full

 

ASCII

 ‐‐‐

<

 

3C

 

 

Full

 

ASCII

 ‐‐‐

K

 

4B

 

 

Full

 

ASCII

 ‐‐‐

=

 

3D

 

 

Full

 

ASCII

 ‐‐‐

L

 

4C

 

 

Full

 

ASCII

 ‐‐‐

>

 

3E

 

 

Full

 

ASCII

 ‐‐‐

M

 

4D

 

 

Full

 

ASCII

 ‐‐‐

?

 

3F

 

 

Full

 

ASCII

 ‐‐‐

N

 

4E

 

 

Full

 

ASCII

 ‐‐‐

@

 

40

 

 

Full

 

ASCII

 ‐‐‐

O

 

4F

 

 

Full

 

ASCII

 ‐‐‐

A

 

41

 

 

Full

 

ASCII

 ‐‐‐

P

 

50

 

 

Full

 

ASCII

 ‐‐‐

B

 

42

 

 

Full

 

ASCII

 ‐‐‐

Q

 

51

 

 

Full

 

ASCII

 ‐‐‐

C

 

43

 

 

Full

 

ASCII

 ‐‐‐

R

 

52

 

 

Full

 

ASCII

 ‐‐‐

D

 

44

 

 

Full

 

ASCII

 ‐‐‐

S

 

53

 

 

Full

 

ASCII

 ‐‐‐

E

 

45

 

 

Full

 

ASCII

 ‐‐‐

T

 

54

 

 

Full

 

ASCII

 ‐‐‐

F

 

46

 

 

Full

 

ASCII

 ‐‐‐

U

 

55

 

 

Full

 

ASCII

 ‐‐‐

G

 

47

 

 

Full

 

ASCII

 ‐‐‐

V

 

56

 

 

Full

 

ASCII

 ‐‐‐

H

 

48

 

 

Full

 

ASCII

 ‐‐‐

W

 

57

 

 

Full

 

ASCII

 ‐‐‐

I

 

49

 

 

Full

 

ASCII

 ‐‐‐

X

 

58

 

 

Full

 

ASCII

 ‐‐‐

J

 

4A

 

 

Full

 

ASCII

 ‐‐‐

Y

 

59

 

 

 

End

 

Of

 

Configuration

 

 

Summary of Contents for Z-5130

Page 1: ...Advanced Miniature CCD Scan Module 1...

Page 2: ......

Page 3: ...Power save mode and examples for trigger command 1 2 April 27 2011 Corrected blurry barcode images in the Performance Test Mode Beeper Selection section 1 3 June 22 2011 Added description in Edge Trig...

Page 4: ...properties of their various respective owners Copyright 2016 All rights reserved For CE countries This scanner is in conformity with CE standards Please note that an approved CE marked power supply un...

Page 5: ...Connection 10 Free interface 10 RS 232 interface 10 USB interface connection 10 Technical Specification 11 Dimension 13 Programming Guide 14 Programming Procedure 15 Default Parameters 16 Scanner Oper...

Page 6: ...ng 45 ITF 2 of 5 Parameter Setting 46 Standard 2 of 5 Parameter Setting 48 Industrial 2 of 5 Parameter Setting 49 UPC EAN JAN Parameter Setting 50 Telepen Parameter Setting 55 Matrix 2 of 5 Parameter...

Page 7: ...ck and easy installation The module has a newly designed CCD scan engine with light beam bright and clear as laser beam that gives user best visual indication and its powerful high resolution CCD acts...

Page 8: ...Cable Test Button NG Power OK Components Description Function OK Indicates a successful reading NG Indicates a failed reading Power Indicates the power status Test Button Used for performance test or...

Page 9: ...ature CCD Scan Module 3 USER S MANUAL Mounting Back Mounting Holes The scanner is designed to embed into any space limited devices and it has 3 screwed mounting holes reserved at the bottom Figure 1 S...

Page 10: ...specula reflection position As to the nature of CCD sensor it will not be able to read any barcodes d The barcode label must be placed within the effective depth of field D O F since it is the effect...

Page 11: ...gle 65 normal Specular Reflection 5 Skew Angle 65 normal Roll Angle 20 normal Prevents reading of a barcode if all the bars are not inside the reading beam or if tilt is more than 20 Figure 2 Skew Pit...

Page 12: ...orter It is highly suggested not place the barcode label at the extremes of depth of field as it is often easy to move out from the reading range Blink Mode After the scanner has been inactive for a p...

Page 13: ...he LED indicators will be turned off and you will hear three short beep sounds This indicates that the module has successfully entered the test mode Place the barcode label within its scan range to ge...

Page 14: ...est button controls both trigger mode and scan performance test mode ST01 When the scanner is set in this mode press the Test button once to scan and press the Test button twice quickly to activate th...

Page 15: ...Beeper disabled in performance test LB14 Beeper enable Beeper enabled in performance test Performance Test Mode Data Transmission Barcode Value Barcode Label Description LB15 Data transmission disable...

Page 16: ...figuration for each interface Free interface RS 45 10P10C for multi interface connection Pin Function 1 RTS_EIA 2 USB_D 3 USB_D 4 GND 5 CTS_EIA 6 RX_EIA 7 Trigger In 8 5V Input 9 N C 10 TX_EIA RS 232...

Page 17: ...can angle Pitch angle Skew angle Specular reflection angle System interface Linear CCD array 617nm visible red LED 280mm UPC EAN 100 PCS 90 330 scans per second 0 1mm 0 07mm actually Code 39 PCS 90 30...

Page 18: ...3 M1 6 0 35 screw hole Regulatory Regulator approval According CE FCC VCCI BSMI RoHS compliant Decode symbology UPC JAN EAN UPC A E EAN 8 EAN 13 ISBN ISSN Code 39 Codabar Code 128 EAN 128 Code 93 Int...

Page 19: ...Advanced Miniature CCD Scan Module 13 USER S MANUAL Dimension...

Page 20: ...y removing power from the scanner The scanner must be properly powered before programming For RS 232C type scanners an external power adapter might be necessary to supply DC power to the scanner Durin...

Page 21: ...and save the new configuration 5 To give up a configuration change power off the scanner before scanning the End of Configuration barcode or scan the Abort barcode 6 For some parameter setting such as...

Page 22: ...ion Parameter Default Same code delay 500ms Scan mode Auto scan Beeping frequency Medium Beeping duration 50ms Power save mode Off Blink mode timers 500ms LED Beep before data transmission On Header a...

Page 23: ...S1 DataBar Disable Code Identifiers Identifier code as factory standard Disable Identifier code as AIM standard Disable Code 39 identifier code M ITF 2 of 5 identifier code I Chinese post code identif...

Page 24: ...F 2 of 5 minimum 4 maximum 14 GS1 DataBar GS1 DataBar Limited minimum 14 maximum 48 GS1 DataBar Expanded minimum 6 Data Formating Code Message Format EAN 13 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13...

Page 25: ...igger command is not controlled by the trigger off command ESC A2 CR When the scanner receives this command the CCD laser light would light up and remain on but the device can only scan once The light...

Page 26: ...Configuration Scanner Operation System Function Setting Barcode Value Barcode Label Description Reset return to factory default Display firmware version Abort exit programming mode with no update KE94...

Page 27: ...nstallation steps refer to Appendix 1 KE01 Enable IBM PC AT PS 2 Keyboard emulation KE05 Enable stand alone keyboard Required no keyboard or key simulator Only available for special firmware version K...

Page 28: ...n Barcode Value Barcode Label Description GR02 Low beeper tone GR01 Medium beeper tone GR03 High beeper tone GR05 Speaker disable Beeper Sound Selection Barcode Value Barcode Label Description GR13 Ve...

Page 29: ...ng Selection Barcode Value Barcode Label Description LB00 LED Beep after transmission Use this barcode to indicate a good read after a barcode has been successfully decoded LB01 LED Beep before transm...

Page 30: ...twice SM05 Repeat mode It is similar to auto scan mode but double reading on the same barcode is permitted if uses trigger Test Button Function Setting Barcode Value Barcode Label Description ST01 Co...

Page 31: ...Beeper disabled in performance test LB14 Beeper enable Beeper enabled in performance test Performance Test Mode Data Transmission Barcode Value Barcode Label Description LB15 Data transmission disabl...

Page 32: ...wer save mode off MT01 Power save after 5 min MT02 Power save after 10 min MT03 Power save after 20 min MT04 Power save after 30 min MT05 Power save after 60 min MT12 Power save after every trigger sc...

Page 33: ...S02 Blink mode timer 10 s LS03 Blink mode timer 15 s LS04 Blink mode timer 20 s LS05 Blink mode timer 30 s LS06 Blink mode timer 60 s LS15 Light beam blinks in blink mode The blink mode is design to p...

Page 34: ...figuration Inter Message Delay Barcode Value Barcode Label Description IM01 0 ms IM02 100 ms IM03 500 ms IM04 1000 ms Inter Character Delay Barcode Value Barcode Label Description IC01 0 ms IC05 2 ms...

Page 35: ...de delay time 100 ms SD03 Same code delay time 200 ms SD04 Same code delay time 300 ms SD05 Same code delay time 400 ms SD06 Same code delay time 500 ms SD07 Same code delay time 600 ms SD08 Same code...

Page 36: ...S MANUAL Start Of Configuration Interface Configuration RS 232C Interface Setting Same Code Delay Barcode Value Barcode Label Description BR09 115200 BR08 57600 BR00 38400 BR01 19200 BR02 9600 BR03 48...

Page 37: ...ue Barcode Label Description PB01 Even parity PB02 Odd parity PB03 Mark parity PB04 Space parity PB05 None parity Stop Bit Barcode Value Barcode Label Description SB01 1 stop bit SB02 2 stop bit Data...

Page 38: ...Xon Xoff HP04 RTS CTS LB07 Enable beeper on BEL character LB08 Ignore beep on BEL character LB09 Disable ACK NAK timeout beeper RT01 ACK NAK response time 300 ms RT03 ACK NAK response time 500 ms RT05...

Page 39: ...alue Barcode Label Description DT11 RS 232 message terminator none DT12 RS 232 message terminator CR LF DT13 RS 232 message terminator CR DT14 RS 232 message terminator LF DT15 RS 232 message terminat...

Page 40: ...key emulation enable CP06 Function key emulation disable CP18 Send number as normal data CP19 Send number as keypad data CP20 Alphabet follow as keyboard CP21 Alphabet always upper case CP22 Alphabet...

Page 41: ...to set quiet zones and spaces low and bars high WO02 Wand emulation data output black low Scan this barcode to set quiet zones and spaces high and bars low WO03 Idle high Idle state refers to the TTL...

Page 42: ...on speed normal WS04 Wand emulation speed high This option allows the transmission of wand emulation at 300us narrow element width WS05 Wand emulation speed higher This option allows the transmission...

Page 43: ...smission none CB06 Codabar start stop character transmission A B C D CB07 Codabar start stop character transmission DC1 DC4 CB08 Codabar start stop character transmission a t b n c d e CB09 Codabar ma...

Page 44: ...alue Barcode Label Description CB13 No check character CB14 Validate modulo 16 but don t transmit CB15 Validate modulo 16 and transmit DC50 Codabar data redundant check off DC51 Codabar data redundant...

Page 45: ...e 39 disable RC13 Code 32 enable RD13 Code 32 disable DC00 Code 39 data redundant check off DC01 Code 39 data redundant check 1 DC02 Code 39 data redundant check 2 DC03 Code 39 data redundant check 3...

Page 46: ...late but without transmit 3907 No check character 3908 Code 39 maximum length setting 3909 Code 39 minimum length setting Confirm to save this setting required for reading full ASCII table and length...

Page 47: ...redundant check 1 DC32 Code 93 data redundant check 2 DC33 Code 93 data redundant check 3 9301 Code 93 maximum length setting 9302 Code 93 minimum length setting Confirm to save this setting required...

Page 48: ...f DC41 Code 128 data redundant check 1 DC42 Code 128 data redundant check 2 DC43 Code 128 data redundant check 3 1801 Code128 FNC2 concatenation enable 1802 Code128 FNC2 concatenation disable 1803 No...

Page 49: ...ode disable DC60 Chinese post code data redundant check off DC61 Chinese post code data redundant check 1 DC62 Chinese post code data redundant check 2 DC63 Chinese post code data redundant check 3 SZ...

Page 50: ...ng MS02 MSI Plessy minimum length setting Confirm to save this setting required for reading full ASCII table and length setting SET MS03 MSI Plessy double check digit calculate but not transmit MS04 M...

Page 51: ...1102 Code 11 minimum length setting Confirm to save this setting required for reading full ASCII table and length setting SET 1103 Code 11 one check digit verification 1104 Code 11 two check digit ver...

Page 52: ...D04 ITF 2 of 5 disable RC09 IATA code enable RD09 IATA disable DC80 ITF 25 data redundant check off DC81 ITF25 data redundant check 1 DC82 ITF25 data redundant check 2 DC83 ITF25 data redundant check...

Page 53: ...e Barcode Label Description IT01 ITF 2 of 5 code maximum length setting IT02 ITF 2 of 5 code minimum length setting IT06 ITF 2 of 5 one fixed length setting IT07 ITF 2 of 5 two fixed length setting Co...

Page 54: ...5 code disable D051 Standard 2 of 5 code maximum length setting D052 Standard 2 of 5 code minimum length setting Confirm to save this setting required for reading full ASCII table and length setting...

Page 55: ...ode disable D251 Industrial 2 of 5 code maximum length setting D252 Industrial 2 of 5 code minimum length setting Confirm to save this setting required for reading full ASCII table and length setting...

Page 56: ...convert to ISSN ISBN enable RD11 EAN convert to ISSN ISBN disable RC03 UPC EAN JAN enable RD03 UPC EAN JAN disable UE01 UPC EAN JAN all enable UE02 EAN 8 or EAN 13 enable UE03 UPC A and EAN 13 enable...

Page 57: ...PC A format disable UE15 Force UPC A to EAN 13 format enable UE16 Force UPC A to EAN 13 format disable UE44 Force EAN 8 to EAN 13 format enable UE45 Force EAN 8 to EAN 13 format disable UE17 Transmit...

Page 58: ...N 13 check digit disable UE27 Transmit UPC A leading character enable UE28 Transmit UPC A leading character disable UE30 Add on format with separator UE31 Add on format without separator UE60 EAN 13 c...

Page 59: ...ta redundant check 1 DC16 UPC E data redundant check 2 DC17 UPC E data redundant check 3 DC20 EAN 13 data redundant check off DC21 EAN 13 data redundant check 1 DC22 EAN 13 data redundant check 2 DC23...

Page 60: ...or 978 977 bookland Supplement requirement not sent for other UE38 EAN UPC addon mandatory for 978 977 bookland Supplement requirement optionally for other UE42 EAN UPC addon mandatory for 491 Japanes...

Page 61: ...dule 55 USER S MANUAL Start Of Configuration Telepen Parameter Setting Barcode Value Barcode Label Description RC25 Telepen enable RD25 Telepen disable TE03 Telepen numeric mode enable TE04 AIM Telepe...

Page 62: ...2 Matrix 2 of 5 disable D151 Matrix 2 of 5 maximum length setting D152 Matrix 2 of 5 minimum length setting Confirm to save this setting required for reading full ASCII table and length setting SET D1...

Page 63: ...Formally RSS Limited GS1 DataBar Limited Group 3 GS1 DataBar Expanded Formally RSS Expanded GS1 DataBar Expanded GS1 DataBar Expanded Stacked GS1 DataBar Omnidirectional Formally RSS 14 Barcode Value...

Page 64: ...Value Barcode Label Description RC16 GS1 DataBar Limited enable RD16 GS1 DataBar Limited disable SS10 Transmit GS1 DataBar Limited check digit SS11 Don t transmit GS1 DataBar Limited check digit SS12...

Page 65: ...panded enable RD17 GS1 DataBar Expanded disable SS07 GS1 DataBar Expanded EAN 128 emulation enable SS06 GS1 DataBar Expanded EAN 128 emulation disable SS08 GS1 DataBar Expanded check digital enable SS...

Page 66: ...IS03 Enable identifier code table as AIM standard CI01 Code 39 identifier code setting CI02 ITF 2 of 5 identifier code setting CI03 Chinese Post Code identifier code setting CI04 UPC E identifier cod...

Page 67: ...de setting CI12 GS1 DataBar Omnidirectional identifier code setting CI13 GS1 DataBar Limited identifier code setting CI14 GS1 DataBar expanded identifier code setting CI15 Industrial 2 of 5 identifier...

Page 68: ...de Label Description CP11 Add code length as header enable 2 digits CP12 Add code length as header disable 2 digits HT01 Header Preamble HT02 Trailer Postamble HT03 Truncate header character HT04 Trun...

Page 69: ...nable USB virtual COM port 1 Connect the handheld scanner and the host e g a PC with a USB interface cable 2 Enable USB virtual COM port with programming barcodes on page 21 3 After the programming th...

Page 70: ...t Example If the barcode length is 4 to 12 digits the steps would be as below Start of Configuration Set up minimum barcode length Set up maximum barcode length End of Configuration Start Set up barco...

Page 71: ...row 05 Full ASCII DC4 Function key F4 14 Full ASCII ACK Function key Down arrow 06 Full ASCII NAK Function key F5 15 Full ASCII BEL Function key Left arrow 07 Full ASCII SYN Function key F6 16 Full AS...

Page 72: ...L 1F Full ASCII 2E Full ASCII SP 20 Full ASCII 2F Full ASCII 21 Full ASCII 0 30 Full ASCII 22 Full ASCII 1 31 Full ASCII 23 Full ASCII 2 32 Full ASCII 24 Full ASCII 3 33 Full ASCII 25 Full ASCII 4 34...

Page 73: ...3E Full ASCII M 4D Full ASCII 3F Full ASCII N 4E Full ASCII 40 Full ASCII O 4F Full ASCII A 41 Full ASCII P 50 Full ASCII B 42 Full ASCII Q 51 Full ASCII C 43 Full ASCII R 52 Full ASCII D 44 Full ASCI...

Page 74: ...I 5C Full ASCII k 6B Full ASCII 5D Full ASCII l 6C Full ASCII 5E Full ASCII m 6D Full ASCII _ 5F Full ASCII n 6E Full ASCII 60 Full ASCII o 6F Full ASCII a 61 Full ASCII p 70 Full ASCII b 62 Full ASCI...

Page 75: ...e 69 USER S MANUAL Start Of Configuration Full ASCII Code 39 Table Code 39 ASCII Hexa code Full ASCII x 78 Full ASCII y 79 Full ASCII z 7A Full ASCII 7B Full ASCII 7C Full ASCII 7D Full ASCII 7E Full...

Reviews: