Scanner Outline and Indicator   

 

 

Figure 2 

 

Wake up 
scanner 

When the scanner enters into the sleep mode, pressing this 
switch can wake the scanner up. The sleep mode feature can be 
programmed by using the menu labels from the Programming 
Guide. 
 

 

The default time-out setting for the sleep mode is 
to switch off laser after 10 minutes, and switch off 
motor after 30 minutes.

     

 

When the scanner is in sleep mode, the LED is 
intermittently flashing red.

 

Single -line 
pattern 

Pick up the scanner, press and release the trigger to activate the 
single line scan mode 

Button

 

Beeper tone 
selection 

When the scanner is sitting in the adjustable stand, press down 
this button for 5 seconds, and it will automatically change the 
beeper volume. 

LED 

A red LED indicates the scanner is ready to read a barcode while a green LED 
indicates a good read. 

Good Read 

Buzzer 

If the data is captured correctly, the buzzer will be heard. Both the volume and 
frequency are programmable by using the menu labels from the Programming 
Guide. 

Adjustable 

stand 

This stand allows you to direct the scan pattern in a way that is the best for your 
application by adjusting the scanner window forward or backward. 

Power Link 
interface 
cable 

Connect the external AC/DC power adaptor into the power jack on the power 
link cable. And the interface connector provides the communication between the 
scanner and host terminal 

Summary of Contents for Z-6070 Series

Page 1: ...SYMBOL 100 PIRY ins zebex OPTICON cino T S C Honeywell SHENZHEN XIN HUA HAN SCIENCE AND TECHNOLOGY CO LTD 3007 11 0755 83981612 0755 83981617 0755 83558013 7106 www scanshop cn 400 609 8831 HR1030 RC...

Page 2: ...i...

Page 3: ......

Page 4: ...erence Operation of this equipment in a residential area can cause interference to radio or television reception This can be determined by turning the equipment off and on The user is encouraged to tr...

Page 5: ...ranscribed or translated into any language or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express written consent and auth...

Page 6: ...Template Installation if required 6 Connecting the Scanner 7 Replacing the Interface Cable 10 How to Scan 11 Single Line Mode 13 Sleep mode 14 LED and Beeper Indications 15 Changing Beeper Volume Usi...

Page 7: ......

Page 8: ...are decode technology to provide real time decode capability to effectively shorten customer transaction time Its broad scan field could effectively facilitate scanning barcodes on products in all kin...

Page 9: ...Hands free scanner B Adjustable stand optional Communication and power link Cable according to order Keyboard wedge cable for PC AT PS2 DB 9 female connector RS232 cable DTE pin out DB 9 female conne...

Page 10: ...er tone selection When the scanner is sitting in the adjustable stand press down this button for 5 seconds and it will automatically change the beeper volume LED A red LED indicates the scanner is rea...

Page 11: ...interface cable to the host refer to your host manual to locate the correct port 3 Plug the power supply into the power jack on the interface cable 4 Plug the other end of the power supply into an AC...

Page 12: ...he buzzer gives 3 string long beep sound When the self test is completed the LED status will return red 5 Present the test barcode below to the scanner If the scanner is functioning properly it will i...

Page 13: ...ter top The base template can be mounted on a flat counter top by the following steps 1 Put the template at where you want to fix the stand 2 Screw down to mount the template onto the counter M4 or sc...

Page 14: ...o the power jack on the interface cable if the RS 232C port of computer system does not supply power 5 Switch on your computer system 6 Adjust the scanner s parameters if necessary by scanning the app...

Page 15: ...r automatically detects a USB host and defaults to the HID keyboard interface type 1 Make sure that the power of your computer system is switched off 2 Plug the interface cable modular into the scanne...

Page 16: ...l power supply to the power jack on the interface cable if the external power is required 5 Switch on your computer system 6 Adjust the scanner s parameters by scanning the appropriate labels in progr...

Page 17: ...be field replaceable Replacement cable can be obtained from an authorized distributor To replace the cable the following steps should be followed 1 Make sure that the power of your computer system is...

Page 18: ...10 Figure 10 Scanning Operation The scanner supports two scanning patterns Multi line scanning Single line scanning Multi Line Mode In this mode the front scan window is in multi line scan pattern an...

Page 19: ...Dual Laser Omnidirectional Scanner 12 USER S MANUAL Figure 12 scanner in the stand Figure 13 With stand Figure 14 Without stand Figure 15 Presentation scanning Figure 16 Sweep scanning...

Page 20: ...s clerks can switch it to single line scan option simply by pressing one button 1 Pick up the scanner 2 Press and then release the side button left or right and a line pattern would appear It allows y...

Page 21: ...o wake up the unit simply present an object to the scanner window or press the button at the sides The scanner takes 2 steps to enter the sleep mode Firstly laser switches off after 10 minutes secondl...

Page 22: ...gramming mode Flash Red light The scanner enters the sleep mode Steady Red Green light This indicates the scanner has a motor or laser failure For motor failure also with a periodic beeper is heard Re...

Page 23: ...he changed the volume setting use the programming guide to set the changes Maintaining the Scanner This laser scanner rarely needs any maintenance Only an occasional cleaning of the scanner window is...

Page 24: ...d averaged over 10 seconds Do not attempt to remove the protective housing of the scanner as unscanned laser light with a peak output up to 0 8mW would be accessible inside Laser Light Viewer The scan...

Page 25: ...Dual Laser Omnidirectional Scanner 18 USER S MANUAL APPENDIX TECHNICAL SPECIFICATION...

Page 26: ...nition for the scanner port and the connector to be used for the port are as following Pin out Configuration Function PIN Keyboard Wedge RS 232C Wand emulation 1 DC 5V input 2 Keyboard Clock N C N C 3...

Page 27: ...rs LED Two color LED green red Beeper Operation Programmable tone and beep time System Interfaces Keyboard RS 232C USB1 1 Wand Physical Height 181 5mm Depth 115 0mm Width 100 0mm Weight 245g stand exc...

Page 28: ...Dual Laser Omnidirectional Scanner 21 USER S MANUAL Dimensions...

Page 29: ...wake up the scanner or use the wake protocol The LED remains red and green Possible failure of the scanning safeguard circuit Disconnect the scanner from its power source immediately and contact your...

Reviews: