background image

 

Z

900X

 

13

 

 

U

SER

S

 

M

ANUAL

Using

 

the

 

Data

 

Collector

 

Refer

 

to

 

the

 

following

 

section

 

to

 

learn

 

how

 

to

 

use

 

the

 

data

 

collector.

 

Scanning

 

and

 

Keying

 

in

 

Data

 

The

 

keypad

 

includes

 

alphanumeric,

 

assorted

 

characters,

 

navigation

 

and

 

function

 

buttons.

 

 

 

Scanning

 

the

 

Barcode

 

Data

 

1.

 

Power

 

on

 

the

 

device

 

and

 

select

 

“1.Collect”

 

to

 

enter

 

scanner

 

mode.

 

Press

 

and

 

hold

 

the

 

yellow

 

SCAN

 

button.

 

A

 

light

 

beam

 

will

 

be

 

activated

 

and

 

shoot

 

out

 

from

 

the

 

window

 

at

 

the

 

lower

 

front

 

end

 

of

 

the

 

data

 

collector.

 

Please

 

see

 

the

 

Run

 

Task

 

section

 

in

 

the

 

User’s

 

Manual

 

for

 

more

 

details.

 

 

2.

 

Aim

 

the

 

beam

 

at

 

the

 

barcode

 

to

 

be

 

scanned.

 

A

 

beep

 

will

 

be

 

given

 

and

 

the

 

beam

 

will

 

disappear

 

if

 

the

 

data

 

scanned

 

has

 

been

 

successfully

 

decoded

 

by

 

the

 

data

 

collector.

 

The

 

decoded

 

message

 

will

 

then

 

be

 

displayed

 

in

 

the

 

LCD.

 

3.

 

The

 

scanned

 

data

 

will

 

be

 

stored

 

as

 

soon

 

as

 

the

 

SCAN

 

button

 

is

 

released,

 

and

 

the

 

next

 

barcode

 

is

 

ready

 

to

 

be

 

scanned.

 

Up/Down

 

buttons

Enter

 

button

Scan

 

button

ESC

 

button

Back

 

space

 

button

Function

 

button

Alpha

 

(

α

)

button

 

Summary of Contents for Z 900 Series

Page 1: ...su Portable Data Collector Series Z 9000 Version 1 0 User s Manual ZEBEX INDUSTRIES INC WWW ZEBEX COM...

Page 2: ...sted below Version Date Description of Version 1 0 05 01 2013 Initial release 1 1 10 09 2013 Added firmware update info 1 2 10 25 2013 Corrected resetting procedure 1 3 08 22 2014 Auto charger off tim...

Page 3: ...to make changes in product design without reservation and without notification The material in this guide is for information only and is subject to change without notice All trademarks mentioned here...

Page 4: ...cuit a battery or allow metallic or conductive objects to contact the battery terminals Do not modify or remanufacture attempt to insert foreign objects into the battery immerse or expose to water or...

Page 5: ...used for a long time If the battery is left unused for more than 3 months you need to charge the battery before use If the battery is not installed recharge the battery every 6 months to prevent damag...

Page 6: ...TTING STARTED 7 INSERTING BATTERY 7 CHARGING THE BATTERY 7 INSTALLATION 8 POWER ON THE DEVICE 8 CONNECTING TO PC 9 Connecting via Cradle 9 Running the Device on PC 9 Loading Application from PC 10 Loa...

Page 7: ...v Delete Data 16 Reader Test 16 Set Date Time 17 Load Application 17 Memory Power 17 Calculator 17 Load Lookup 18 PROGRAM MANAGER 18 Menu Description 18 Download 19 Activate 20 Upload 21 UPDATING FIRM...

Page 8: ......

Page 9: ...ive LCD for a wide working condition No programming background required 10 menus 10 forms 3 lookup for maximum flexibility Application Simulator PC System Requirement Windows XP Service Pack 2 or abov...

Page 10: ...Hole Used to attach hand straps LED Indicator Indicates reading status Red for scanning error such as wrong data type or no data match and green for good read LCD Screen Display various data when a pr...

Page 11: ...rent 500mA MAX Auto charger off timer 6 2 hrs Memory 8MB FLASH ROM 4MB SRAM with ability to data retentions Keypad 21 keys alpha numeric include Power and SCAN key with white back light LCD Screen LCD...

Page 12: ...ault Codabar Enable Code 39 Enable Code 93 Enable Code 128 Enable Code 11 Disable Italian Pharmacode Disable Chinese Post Code Disable Interleaved 2 of 5 Enable EAN UPC Enable MSI Disable Telepen Para...

Page 13: ...Codabar N Code 39 M Code 93 L Code 128 K Code 11 O Chinese Post Code H Interleaved 2 of 5 I EAN 13 F UPC A A UPC E E EAN 8 FF MSI P Industrial 2 of 5 D Standard 2 of 5 S Matrix 2 of 5 G GS1 Databar R...

Page 14: ...Maximum 32 Minimim 6 Maximum 62 Minimim 3 Maximum 62 Minimim 3 Code 39 Code 93 Code 128 Maximum 62 Minimim 3 Chinese Post Code Maximum 16 Minimim 10 Maximum 32 Minimim 4 Interleaved 2 of 5 MSI Maximu...

Page 15: ...3 Insert the battery with the top side in first then the side with battery contact The battery is held in place by a small lock on the bottom of the compartment Push the battery in until it clicks int...

Page 16: ...Double click the found new hardware icon to pull up the window if it does not appear automatically Select No not this time to continue 3 Click Next to continue installation 4 Click Install from a lis...

Page 17: ...site The system should assign a COM port to the device after the driver installation Connect the power adapter to the cradle when necessary Make sure the unit is turned on after the cable is connected...

Page 18: ...e data collector 3 Select Send Lookup in ZAC Resetting the Device 1 Press and hold the and buttons then press the Power button 2 Release the Power button when you see the reset message on the screen 3...

Page 19: ...nu option Press ESC to go to the previous screen Menu Screen Menu Description Menu Description Collect Select this option to start recording data You can scan barcodes or enter the data manually Uploa...

Page 20: ...elect this option for 1 Settings 2 Browse Data 3 Delete Data 4 Reader Test 5 Set Date Time 6 Load Application 7 Memory Power 8 Calculator 9 Load Lookup when lookup is available this option becomes opt...

Page 21: ...vated and shoot out from the window at the lower front end of the data collector Please see the Run Task section in the User s Manual for more details 2 Aim the beam at the barcode to be scanned A bee...

Page 22: ...lays the numerical keys and their corresponding alphabetical characters Press the key and the numerical character corresponding to the key will be displayed Pressing the key to switch between alphabet...

Page 23: ...ing for downloading Baud Rate 9600 19200 38400 57600 115200 View the baud rate for connection Backlight Turn B L off Turn B L on Turn the backlight on or off Data Deletion Manual Automatic No Decide d...

Page 24: ...te data Delete Data Use this option to delete inputted data 1 Select 3 Utilities and 3 Delete Data from the menu 2 Select Date File or a Lookup to delete data 3 Select All data to delete all inputted...

Page 25: ...vious instructions to connect the data collector 2 Select 3 Utilities and 6 Load Application on the data collector 3 Select Send Application in ZAC Memory Power Use this option to display the memory a...

Page 26: ...okup on the data collector 3 Select Send Lookup in ZAC Program Manager Press the numeric key 8 and power button at the same time to enter Program Manager Menu Description Menu Description Download Dow...

Page 27: ...ter the selection connection can only be made when you place the device on the cradle 3 If you selected 1 5 in step 2 you must also select 2 Activate to begin the download procedure 4 If you selected...

Page 28: ...n from 1 5 and press Enter for detailed information 2 Press F3 to activate once in the detailed information screen 3 Press ESC to exit Program Manager after activation to begin using ZEBEX OS Customer...

Page 29: ...rogram to PC When uploading the bin file select 1 5 or A to store the file After the selection connection can only be made when you place the device on the cradle Upload 1 z9000_fw_x xxx 2 3 4 5 A z90...

Page 30: ...am Manager 3 Select 1 Download and press Enter to enter the Download screen 4 Select an empty slot to to store the file and press Enter Please remember the slot number you selected for later use Downl...

Page 31: ...place the unit in the cradle when ready Please install the Z 9000 driver if necessary 6 On your computer please open the Boot Load Utility default path Start All Programs ZEBEX ZAC Boot Load Utility 7...

Page 32: ...select the firmware file stored on your computer 10 Select Start Boot Load to transfer the file to Z 9000 You will hear a beep sound when the transfer is done The Download screen appears on the Z 9000...

Page 33: ...the Activate screen when the update is done Upgrade Warning Incorrect operation may cause dysfunction or damage to the unit Please choose the correct firmware file Do not remove power or reboot the sy...

Reviews: