background image

 

Z

900X

 

ii

 
 

Battery

 

Safety

 

 

The

 

area

 

in

 

which

 

the

 

units

 

are

 

charged

 

should

 

be

 

clear

 

of

 

debris

 

and

 

combustible

 

materials

 

or

 

chemicals.

  

Particular

 

care

 

should

 

be

 

taken

 

where

 

the

 

device

 

is

 

charged

 

in

 

a

 

non

 ‐

commercial

 

environment.

   

 

Follow

 

battery

 

usage,

 

storage,

 

and

 

charging

 

guidelines

 

found

 

in

 

the

 

user

 

guide.

   

 

Improper

 

battery

 

use

 

may

 

result

 

in

 

a

 

fire,

 

explosion,

 

or

 

other

 

hazard.

   

 

To

 

charge

 

the

 

device

 

battery,

 

the

 

battery

 

and

 

charger

 

temperature

 

must

 

be

 

between

 

0

~+45

 

 

Do

 

not

 

use

 

incompatible

 

batteries

 

and

 

chargers.

 

Use

 

of

 

an

 

incompatible

 

battery

 

or

 

charger

 

may

 

present

 

a

 

risk

 

of

 

fire,

 

explosion,

 

leakage,

 

or

 

the

 

hazard.

   

 

Do

 

not

 

disassemble

 

or

 

open,

 

crush,

 

bend

 

or

 

deform,

 

puncture,

 

or

 

shred.

   

 

Severe

 

impact

 

from

 

dropping

 

any

 

battery

operated

 

device

 

on

 

a

 

hard

 

surface

 

could

 

cause

 

the

 

battery

 

to

 

overheat.

   

 

Do

 

not

 

short

 

circuit

 

a

 

battery

 

or

 

allow

 

metallic

 

or

 

conductive

 

objects

 

to

 

contact

 

the

 

battery

 

terminals.

   

 

Do

 

not

 

modify

 

or

 

remanufacture,

 

attempt

 

to

 

insert

 

foreign

 

objects

 

into

 

the

 

battery,

 

immerse

 

or

 

expose

 

to

 

water

 

or

 

other

 

liquids,

 

or

 

expose

 

to

 

fire,

 

explosion,

 

or

 

other

 

hazard.

   

 

Do

 

not

 

leave

 

or

 

store

 

the

 

equipment

 

in

 

or

 

near

 

areas

 

that

 

might

 

get

 

very

 

hot,

 

such

 

as

 

in

 

a

 

parked

 

vehicle

 

or

 

near

 

a

 

radiator

 

or

 

other

 

heat

 

source.

 

Do

 

not

 

place

 

battery

 

into

 

a

 

microwave

 

oven

 

or

 

dryer.

   

 

Battery

 

usage

 

by

 

children

 

should

 

be

 

supervised.

   

 

Please

 

follow

 

local

 

regulations

 

to

 

promptly

 

dispose

 

of

 

used

 

re

chargeable

 

batteries.

   

 

Do

 

not

 

dispose

 

of

 

batteries

 

in

 

fire.

   

 

 

Seek

 

medical

 

advice

 

immediately

 

if

 

a

 

battery

 

has

 

been

 

swallowed.

 

In

 

the

 

event

 

of

 

a

 

battery

 

leak,

 

do

 

not

 

allow

 

the

 

liquid

 

to

 

come

 

in

 

contact

 

with

 

the

 

skin

 

or

 

eyes.

 

If

 

contact

 

has

 

been

 

made,

 

wash

 

the

 

affected

 

area

 

with

 

large

 

amounts

 

of

 

water

 

and

 

seek

 

medical

 

advice.

 

 

Do

 

not

 

short

 

the

 

battery

 

terminals.

 

The

 

battery

 

could

 

overheat.

   

 

Do

 

not

 

attempt

 

to

 

split

 

or

 

peel

 

the

 

outer

 

casing.

   

 

Summary of Contents for Z 900 Series

Page 1: ...su Portable Data Collector Series Z 9000 Version 1 0 User s Manual ZEBEX INDUSTRIES INC WWW ZEBEX COM...

Page 2: ...sted below Version Date Description of Version 1 0 05 01 2013 Initial release 1 1 10 09 2013 Added firmware update info 1 2 10 25 2013 Corrected resetting procedure 1 3 08 22 2014 Auto charger off tim...

Page 3: ...to make changes in product design without reservation and without notification The material in this guide is for information only and is subject to change without notice All trademarks mentioned here...

Page 4: ...cuit a battery or allow metallic or conductive objects to contact the battery terminals Do not modify or remanufacture attempt to insert foreign objects into the battery immerse or expose to water or...

Page 5: ...used for a long time If the battery is left unused for more than 3 months you need to charge the battery before use If the battery is not installed recharge the battery every 6 months to prevent damag...

Page 6: ...TTING STARTED 7 INSERTING BATTERY 7 CHARGING THE BATTERY 7 INSTALLATION 8 POWER ON THE DEVICE 8 CONNECTING TO PC 9 Connecting via Cradle 9 Running the Device on PC 9 Loading Application from PC 10 Loa...

Page 7: ...v Delete Data 16 Reader Test 16 Set Date Time 17 Load Application 17 Memory Power 17 Calculator 17 Load Lookup 18 PROGRAM MANAGER 18 Menu Description 18 Download 19 Activate 20 Upload 21 UPDATING FIRM...

Page 8: ......

Page 9: ...ive LCD for a wide working condition No programming background required 10 menus 10 forms 3 lookup for maximum flexibility Application Simulator PC System Requirement Windows XP Service Pack 2 or abov...

Page 10: ...Hole Used to attach hand straps LED Indicator Indicates reading status Red for scanning error such as wrong data type or no data match and green for good read LCD Screen Display various data when a pr...

Page 11: ...rent 500mA MAX Auto charger off timer 6 2 hrs Memory 8MB FLASH ROM 4MB SRAM with ability to data retentions Keypad 21 keys alpha numeric include Power and SCAN key with white back light LCD Screen LCD...

Page 12: ...ault Codabar Enable Code 39 Enable Code 93 Enable Code 128 Enable Code 11 Disable Italian Pharmacode Disable Chinese Post Code Disable Interleaved 2 of 5 Enable EAN UPC Enable MSI Disable Telepen Para...

Page 13: ...Codabar N Code 39 M Code 93 L Code 128 K Code 11 O Chinese Post Code H Interleaved 2 of 5 I EAN 13 F UPC A A UPC E E EAN 8 FF MSI P Industrial 2 of 5 D Standard 2 of 5 S Matrix 2 of 5 G GS1 Databar R...

Page 14: ...Maximum 32 Minimim 6 Maximum 62 Minimim 3 Maximum 62 Minimim 3 Code 39 Code 93 Code 128 Maximum 62 Minimim 3 Chinese Post Code Maximum 16 Minimim 10 Maximum 32 Minimim 4 Interleaved 2 of 5 MSI Maximu...

Page 15: ...3 Insert the battery with the top side in first then the side with battery contact The battery is held in place by a small lock on the bottom of the compartment Push the battery in until it clicks int...

Page 16: ...Double click the found new hardware icon to pull up the window if it does not appear automatically Select No not this time to continue 3 Click Next to continue installation 4 Click Install from a lis...

Page 17: ...site The system should assign a COM port to the device after the driver installation Connect the power adapter to the cradle when necessary Make sure the unit is turned on after the cable is connected...

Page 18: ...e data collector 3 Select Send Lookup in ZAC Resetting the Device 1 Press and hold the and buttons then press the Power button 2 Release the Power button when you see the reset message on the screen 3...

Page 19: ...nu option Press ESC to go to the previous screen Menu Screen Menu Description Menu Description Collect Select this option to start recording data You can scan barcodes or enter the data manually Uploa...

Page 20: ...elect this option for 1 Settings 2 Browse Data 3 Delete Data 4 Reader Test 5 Set Date Time 6 Load Application 7 Memory Power 8 Calculator 9 Load Lookup when lookup is available this option becomes opt...

Page 21: ...vated and shoot out from the window at the lower front end of the data collector Please see the Run Task section in the User s Manual for more details 2 Aim the beam at the barcode to be scanned A bee...

Page 22: ...lays the numerical keys and their corresponding alphabetical characters Press the key and the numerical character corresponding to the key will be displayed Pressing the key to switch between alphabet...

Page 23: ...ing for downloading Baud Rate 9600 19200 38400 57600 115200 View the baud rate for connection Backlight Turn B L off Turn B L on Turn the backlight on or off Data Deletion Manual Automatic No Decide d...

Page 24: ...te data Delete Data Use this option to delete inputted data 1 Select 3 Utilities and 3 Delete Data from the menu 2 Select Date File or a Lookup to delete data 3 Select All data to delete all inputted...

Page 25: ...vious instructions to connect the data collector 2 Select 3 Utilities and 6 Load Application on the data collector 3 Select Send Application in ZAC Memory Power Use this option to display the memory a...

Page 26: ...okup on the data collector 3 Select Send Lookup in ZAC Program Manager Press the numeric key 8 and power button at the same time to enter Program Manager Menu Description Menu Description Download Dow...

Page 27: ...ter the selection connection can only be made when you place the device on the cradle 3 If you selected 1 5 in step 2 you must also select 2 Activate to begin the download procedure 4 If you selected...

Page 28: ...n from 1 5 and press Enter for detailed information 2 Press F3 to activate once in the detailed information screen 3 Press ESC to exit Program Manager after activation to begin using ZEBEX OS Customer...

Page 29: ...rogram to PC When uploading the bin file select 1 5 or A to store the file After the selection connection can only be made when you place the device on the cradle Upload 1 z9000_fw_x xxx 2 3 4 5 A z90...

Page 30: ...am Manager 3 Select 1 Download and press Enter to enter the Download screen 4 Select an empty slot to to store the file and press Enter Please remember the slot number you selected for later use Downl...

Page 31: ...place the unit in the cradle when ready Please install the Z 9000 driver if necessary 6 On your computer please open the Boot Load Utility default path Start All Programs ZEBEX ZAC Boot Load Utility 7...

Page 32: ...select the firmware file stored on your computer 10 Select Start Boot Load to transfer the file to Z 9000 You will hear a beep sound when the transfer is done The Download screen appears on the Z 9000...

Page 33: ...the Activate screen when the update is done Upgrade Warning Incorrect operation may cause dysfunction or damage to the unit Please choose the correct firmware file Do not remove power or reboot the sy...

Reviews: