Requirements

  •  Minimum of 25 psi continuous operating water pressure

  •  Maximum 500 SUS coolant concentrate viscosity

  •  USE DISCHARGE HOSE PROVIDED. Longer lengths will less-

en concentration or provide none at all.

  •  Use proper fittings for water input and output. Restriction of 

either will reduce vacuum pressure. Required fitting sizes are 

noted below.

  •  Keep drum upright

Installation Instructions

  1.  Configure the standpipe to fit your concentrate container 

type. Universal mixers will need to be adjusted depending 

upon the required standpipe length. Use both standpipes 

and the coupler for tote applications. You may need to re-

move and reattach the check valve to the lower end of the 

standpipe configuration.

  2.  Remove the bung cap from the concentrate container.

  3.  Insert the required length standpipe into the container and 

screw bushing into the 2” female thread in drum. Tighten the set screw.

  4.  Unfasten the breather cap from the concentrate lid.

  5.  Connect the included shut-off valve to the mixer head.

  6.  Connect the water line to the shut-off valve using the proper sized fitting (see chart below).

  7.  Attach the 40” discharge hose, provided. Longer lengths will lessen concentration output. If delivering mix 

through a garden hose, for instance, a proportioning pump is required.

  8.  Open the water valve, and after emulsion is dispensed, check the proportion with a refractometer, then 

adjust the dial as necessary. Once the dial setting has been determined, secure with the locknut located 

below the dial.

    • Dial settings are for reference only. Varying water pressure and fluid viscosities will produce different 

mixing ratios.

    • Turning the dial clockwise (right) will bottom out the needle valve onto its seat in the mixer body, pre-

venting coolant concentrate from entering the mixing chamber. At this point, the number zero should be 

in-line with the pointer.

    • Turning the dial counter-clockwise (left) will open the inlet orifice permitting increasing amounts of cool-

ant concentrate to enter the mixing chamber.

    • Maximum ratio delivered with four full turns of the dial.

®

(SS models 

for caustic 

concentrate)

Part# 

Ratio Range 

% Range  GPM 

Fitting In  Fitting Out 

Application 

MIX0327 

15:1 - 45:1 

0-7 

3/8” 

1/2” 

Barrel

MIXU0327 

15:1 - 45:1 

0-7  

3/8” 

1/2”  

Pail, barrel, or tote

MIX03725SS 

3:1 - 15:1  

0-25 

3/8” 

1/2”  

Barrel

MIXU03725 

3:1 - 15:1 

0-25 

3/8” 

1/2” 

Pail, barrel, or tote

MIXU03725SS  100:1 - 4:1 

0-25 

3/8” 

1/2” 

Barrel

MIX1027 

15:1 - 45:1 

0-7 

10 

1/2” 

3/4” 

Barrel

MIXU1027 

15:1 - 45:1 

0-7 

10 

1/2” 

3/4” 

Pail, barrel, or tote

MIX10725 

3:1 - 15:1 

0-25 

10 

1/2” 

3/4” 

Barrel

MIX10725SS  100:1 - 4:1 

0-25 

10 

1/2” 

3/4” 

Barrel

MIXU10725 

3:1 - 15:1 

0-25 

10 

1/2” 

3/4” 

Pail, barrel, or tote

MIXU10725SS  100:1 - 4:1 

0-25 

10 

1/2” 

3/4” 

Pail, barrel, or tote