ZyPerUHD60
Installation Environment
The general area where the ZyPerUHD60 unit is to be installed shall be clean and free of
obstructions or clutter.
Mounting Options
•
Unit may be mounted horizontally
•
Unit may be bolted to a horizontal surface using the provided L-brackets
•
Unit may be mounted vertically only if appropriate clearance is provided around the
grille work for adequate airflow. The appropriate ZyPerUHD60 rack mount kits insure
that airflow space is sufficient when mounting vertically.
•
Units may be stacked in a horizontal orientation providing stack is no higher than 3
units
•
In all cases, insure that the units are rigidly held in place and will not be subject to
impact and there is no possibility of toppling.
•
Do not stack any other equipment or devices on top of the unit weighing more than
3Kg and only if sufficient bracing is provided to protect against toppling.
WARNING: Failure to adhere to these recommendation could result in
unsafe operation, damage to the equipment, or injury to the operators.
Ventilation
Ambient environmental temperature and humidity shall not exceed that specified in the Detailed
Specifications portion of this document.
Ambient temperature in this case refers to the temperature of air entering the device through the
ventilation grille. Care should be taken to not enclose the device or deploy in an fashion where
airflow loops or local “hot spots” can cause the inlet air to rise above the specified limit for
normal operation.
In general 25mm (
≈
1inch) of clearance should be provided around the ventilation openings
unless an external air mover insures that the inlet temperature is at or below the specified limit.
If the equipment is mounted in an enclosed cabinet, it is the job of the installer to insure that
within the cabinet or enclosure the ZyPerUHD60 equipment does not experience local
temperatures in excess of that specified in the Detailed Specifications portion of this document.
Rev: 20231115
Page of
63
77
User Manual