ZyPerUHD60
EMC Information
The ZyPerUHD devices should be mounted and operated in accordance with the guidelines
specified in this guide to maintain the integrity of the expected EMC characteristics.
The supplied Power Supply (AC/DC Conversion unit) should be used. Any other AC/DC supply
has not been tested or verified to perform at the levels indicated in this manual.
Media cables are not provided and the ZyPerUHD devices are generally fairly tolerant of
different types and manufacture styles.
•
Media cables should be of good quality and rated for the performance levels of the
interface to which they are connected.
‣
e.g. 4K HDMI ports should only be connected to HDMI cables rated for 4K
operation at the desired resolutions.
•
HDMI cables shall be of the type incorporating
integral Ferrite cores in order to achieve rated
compliance levels and the cleanest electromagnetic
environment in the vicinity of the unit.
Electromagnetic Emissions
Test
Compliance
Level
Notes
RF emissions: CISPR 11
Group 1
ZyPerUHD emissions are very low and not
expected to cause unintentional interference.
RF emissions: CISPR 11
Class A
Commercial equipment for use in commercial
environments.
Harmonic emissions:
IEC 61000-3-2
Class D
Suitable for use in all commercial and domestic
low-voltage environments.
Voltage fluctuations/ flicker emissions:
IEC 61000-3-3
Compliant
Rev: 20231115
Page of
70
77