M5 – Digital Input settings
Parameter
Description
Unit
M05-01
Input 11 (main PCB)
n/a
M05-02
Input 21 (main PCB)
n/a
M05-03
Input 31 (main PCB)
n/a
M05-04
Input 41 (I/O PCB)
n/a
M05-05
Input 51 (I/O PCB)
n/a
M05-06
Input 61 (I/O PCB)
n/a
M05-07
Input 71 (I/O PCB)
n/a
M05-08
Input 81 (I/O PCB)
n/a
M05-09
Input 91 (I/O PCB)
n/a
M05-11
Actual input 1 (main PCB)
n/a
M05-12
Actual input 2 (main PCB)
n/a
M05-13
Actual input 3 (main PCB)
n/a
M05-14
Actual input 4 (I/O PCB)
n/a
M05-15
Actual input 5 (I/O PCB)
n/a
M05-16
Actual input 6 (I/O PCB)
n/a
M05-17
Actual input 7 (I/O PCB)
n/a
M05-18
Actual input 8 (I/O PCB)
n/a
M05-19
Actual input 9 (I/O PCB)
n/a
1 The digital inputs can be set as follows:
�
9: n/a;
�
19: Enable ComfoAir XL;
�
0: No function;
�
10: n/a;
�
20: Fire Contact (normal closed);
�
1: Ventilation speed 1;
�
11: Frost protection (normal closed);
�
21: Enable Summernight Ventilation;
�
2: Ventilation speed 2;
�
12: Frost protection (normal open);
�
22: Heat/Cool mode (coolmode = closed);
�
3: Ventilation speed 3;
�
13: n/a;
�
23: Reset all failures (reset =closed);
�
4: Ventilation speed 4;
�
14: Enable supply fan;
�
24: Enable Fire Overrule;
�
5: Failure supply fan (normal closed);
�
15: Enable exhaust fan;
�
25: Second setpoint select (Not active when
option 0:Constant flow internal is selected
at M2-10.);
�
6: Failure supply fan (normal open);
�
16: Enable post-heater;
�
7: Failure exhaust fan (normal closed);
�
17: Enable post-cooler;
�
26: Enable time clock
�
8: Failure exhaust fan (normal open);
�
18: Failure (normal closed);
M6 – Relay settings
Parameter
Description
Unit
M06-01
Power Relay 12 (main PCB)
n/a
M06-02
Power Relay 22 (main PCB)
n/a
M06-03
Power Relay 32 (I/O PCB)
n/a
M06-04
Power Relay 42 (I/O PCB)
n/a
M06-05
Potential free Relay 52 (I/O PCB)
n/a
M06-06
Potential free Relay 62 (I/O PCB)
n/a
M06-07
Potential free Relay 72 (I/O PCB)
n/a
M06-08
Potential free Relay 82 (I/O PCB)
n/a
M06-11
Power Relay 13 control (main PCB)
n/a
M06-12
Power Relay 23 control (main PCB)
n/a
M06-13
Power Relay 33 control (I/O PCB)
n/a
M06-14
Power Relay 43 control (I/O PCB)
n/a
M06-15
Potential free Relay 53 control (I/O PCB)
n/a
M06-16
Potential free Relay 63 control (I/O PCB)
n/a
M06-17
Potential free Relay 73 control (I/O PCB)
n/a
M06-18
Potential free Relay 83 control (I/O PCB)
n/a
2 The relays can be set as follows:
�
4 : Bypass valve;
�
9 : Post-Cooler/Heater pump;
�
0 : No function;
�
5 : Post-Heater pump;
�
10: Summernight ventilation active;
�
1 : Alarm (normally open);
�
6 : Post-Cooler pump;
�
11: PreHeater ODA pump (= supply air);
�
2 : Supply Dampers valve;
�
7 : Sifon heating;
�
12: Filter Alarm active;
�
3 : Exhaust Dampers valve;
�
8 : ComfoAir XL active;
�
13: PreHeater ETA pump (= extract air).
3 The relays can have the following state: 0 : Off;
1 : On.