2. Installing your appliance
2.1 Warnings
The flexible cable supplied with your appliance is desi
-
gned to be connected to the mains via a junction box that
must be placed behind the appliance, with no need for a
plug.
In a kitchen or bathroom, the junction box must be
positioned at least 25 cm from the floor.
The appliance must be installed as described in this
document and in accordance with the applicable European
and French standards, including CEI 60364.7.701 and NF
C15-100, as well as the rules of good professional practice.
For other countries (apart from France), the appliance
must be installed in accordance with standards in force and
with rules of good professional practice in the country of
use.
IMPORTANT
The example shown only concerns a
bathtub. For other bathroom fixtures, please consult
your installer.
IMPORTANT
The system must be fitted with an omni
-
polar circuit-breaker with a minimum contact opening of
3mm.
To ensure your system is safe (see figure
①
)
:
- ensure that the bottom of the junction box is positio-
ned at least 10 cm above the floor;
- ensure that an area of at least 50 cm in front of the
appliance is clear of objects which might hinder air
circulation (furniture, chairs, etc.);
- position a shelf at least 10 cm above the top of your
radiator;
- use mounting screws suitable for your wall.
IMPORTANT
This radiator should never be installed
with the control unit positioned topside. (see figure
②
)
ATTENTION
Always turn off the electricity supply (circuit-
b pilot wire) before making any connections.