21 - EN
Fasten the screws to a maximum of 1.5
Nm. This is roughly equal to setting 2 of an
average battery-powered drill.
9. Carry out the self-test in accordance with menu
P76.
2.10 Malfunctions
Malfunctions in the ComfoAir are reported as
follows:
■
The malfunction alert appears on the display.
■
The malfunction indicator on the 3-position
switch lights up;
Malfunction alerts may not appear on the digital
operating device in all cases, even though there is
a malfunction (or problem). A concise explanation
of both types of malfunction (or problem) is given in
the paragraphs below.
2.10.1 Malfunction alerts on the digital
operating device
In the event of a malfunction, the corresponding
malfunction code will be displayed on the digital
operating device of the ComfoAir.
Below is a list of the malfunction alerts on the
digital operating device.
In the chapter about trouble shooting is explained
how to solve these malfunctions
Code
Description
A0
N/A
A1
NTC sensor T1 is defective.
(= outside air temperature)
A2
NTC sensor T2 is defective.
(= supply air temperature)
A3
NTC sensor T3 is defective.
( =return air temperature)
A4
NTC sensor T4 is defective.
(= exhaust air temperature)
A5
Malfunction in the bypass motor.
A6
Malfunction in the
Preheater element motor.
A7
Preheater element does not heat sufficiently.
A8
Preheater element becomes too hot
E1
Exhaust fan not rotating.
E2
Supply fan not rotating.
EA2
No communication between the enthalpy sensor
and the ComfoAir.
,Fil' ,tEr'
Internal Filter is dirty.
2.10.2 3-position switch with
malfunction indicators
The 3-position switches that are fitted with a
malfunction indicator show when a malfunction or
filter dirty alert has occurred. Depending on the type
of the 3-position switch, this is done in one of the
following two ways:
■
3-position switch with malfunction indicator.
In the event of a malfunction or filter dirty alert
the indicator lights up;
■
Wireless 3-position switch with malfunction
indicator.
The malfunction indicators will light up once this
3-position switch is used. One indicator will light
up green to indicate communication has been
established. Subsequently, in the event of a
malfunctionor filter dirty alert both indicators will
flash red 3 times. After that, both indicators will
light up green once more.