22 - EN
EN - 23
Information requirement for RVUs as per EU Regulation No. 1253/2014
Heat Recovery Unit Zehnder ComfoAir Q 600 ST
Supplier name or trade
mark
Zehnder group
Zehnder group
Zehnder group
Zehnder group
Supplier’s model
identifier
ComfoAir Q 600 ST
ComfoAir Q 600 ST
ComfoAir Q 600 ST
ComfoAir Q 600 ST
SEC in [kWh/(m²a)] for
each climate zone
(cold, average, warm)
-75.7
-37.2
-12.6
-76.6
-38.0
-13.3
-78.9
-40.0
-15.1
-82.6
-43.0
-17.8
SEC Class
A+
A
E
A+
A
E
A+
A
E
A+
A+
E
Type of ventilation unit
Bidirectional RVU
Bidirectional RVU
Bidirectional RVU
Bidirectional RVU
Type of drive installed
Multi-speed drive
Multi-speed drive
Variable speed drive
Variable speed drive
Type of heat system1
Recuperative
Recuperative
Recuperative
Recuperative
Thermal efficiency2
90%
90%
90%
90%
Maximum flow rate
[m³/h]3
600
600
600
600
Electric power input
[W]4
345
345
345
345
Sound power level
(LWA) in [dB(A)] 5
51
51
51
51
Reference flow rate in
[m³/h]6
420
420
420
420
Reference pressure
difference [Pa]
50
50
50
50
SPI in [W/(m³/h)]7
0.26
0.26
0.26
0.26
Control factor and
typology
1
Manual control
0.95
Clock-controlled
0.85
Central demand control
0.65
Local demand control
Declared maximum
internal and external
leakage rates (%)8
Intern: 0.6%
Extern: 1.1%
Intern: 0.6%
Extern: 1.1%
Intern: 0.6%
Extern: 1.1%
Intern: 0.6%
Extern: 1.1%
Mixing rate9
-
-
-
-
Position and
description of visual
filter warning
Warning on the display of
the unit or room controller
Warning on the display of
the unit or room controller
Warning on the display of
the unit or room controller
Warning on the display of
the unit or room controller
Internet address
for assembly
and disassembly
instructions
www.zehnder.co.uk
www.zehnder.co.uk
www.zehnder.co.uk
www.zehnder.co.uk
Airflow sensitivity to
pressure variations
[%]10
-
-
-
-
Indoor/outdoor air
tightness [m³/h]11
-
-
-
-
AEC (in kWh
electricity/a) for each
climate zone
(cold, average, warm)
14.0
8.6
8.1
13.4
8.0
7.5
11.7
6.3
5.9
9.3
3.9
3.4
AHS (in kWh primary
energy/a) for each
climate zone
(cold, average, warm)
89.6
45.8
20.7
89.9
46.0
20.8
90.6
46.3
20.9
91.8
46.9
21.2
1: Type of heat recovery: „recuperative“ heat recovery is heat recovery without moving parts (plate heat exchanger).
2: Thermal efficiency: as per EN 13141-7:2010 at a reference flow rate of 50 Pa; as per EN 13141-8:2014 for non-ducted units.
3: Maximum flow rate at 100 Pa of external static pressure difference.
4: Electric power input at maximum flow rate.
5: Noise emitted from housing at reference flow rate.
6: Reference flow rate (70% of the maximum flow rate at 50 Pa of external static pressure difference as per EN 13141-7:2010).
7: As per EN 13141-7:2010 at reference flow rate.
8: As per EN 13141-7:2010; as per EN 13141-8:2014 for non-ducted units.
9: As per EN 13141-8:2014 for non-ducted units.
10: As per EN 13141-8:2014 for non-ducted units: airflow sensitivity to pressure variations at +20 Pa and -20 Pa.
11: As per EN 13141-8:2014 for non-ducted units.
SEC: Specific energy consumption.
SPI: Specific power input.
AEC: Annual electricity consumption.
AHS: Annual heating saved .
Summary of Contents for ComfoAir Q 350 ST
Page 1: ...Cooling Fresh Air Clean Air Heating Ventilation system Zehnder ComfoAir Q User manual ...
Page 4: ...4 EN ...
Page 33: ...EN 33 Data Activity Initials ...
Page 34: ......
Page 35: ......