EN 15
Additional programme values
Submenu
description
Minimum
Maximum
Factory reset
P56
Setting the required
air volume in the house.
• nL: “normal air volume”.
• HL: “high air volume”.
nL
HL
HL
Note:
Setting the air volume is the starting point for programming the air
specifications and setting the fans.
P57
Setting the type of ventilation unit.
• Li = “Left-hand version”.
• re = “right-hand version”.
Li
Re
Li
Note:
The ventilation unit is correctly preprogrammed at the factory.
This setting is lost during a factory reset and will then have to be re-
programmed. The correct setting can be found on the ventilation unit's
identification plate.
P58
Enter controller priorities.
• 0; Priority to highest setting
INCLUDING the signals from
the analogue (0-10V) inputs.
• 1; Priority to highest setting
ExCLUDING the signals from
the analogue (0-10V) ports.
0
1
0
P59
(Optional)
Confirming the presence of an
enthalpy exchanger.
• 0; Enthalpy exchanger fitted
• 1; Enthalpy exchanger with rH
sensor.
• 2; Enthalpy exchanger without
RH sensor.
0 (= No)
2 (= Yes)
0
If an enthalpy exchanger without a sensor is selected, then the protec-
tion programme will not be activated and malfunction alerts EA1 & EA2
will never occur.