Surface Mount knock outs
Cable
Clamps
12
2.6.7
2.6.8
2.6.9
2.6.10
The fan must not be mounted above or closer than 1m to the cooker where it
could be affected by excessive heat or moisture.
Fan Specifications
220-240V ~ 50Hz / 1 Ph. IPX4 30 Watts max.
Cable sizes (max): Fixed flat wiring - 2 core 1mm
2
, 3 core 1/1.5mm
2
When converted to SELV: 24V DC between controller and fan.
Wiring Details 230V Model
Standard Wiring
• Strip cable to correct lengths
as shown in Figure 2.a.
• Insert cable through cable entry
point (A), and then secure cable
using the cable clamp (B).
• Push the wires into the terminal block (C) as per the wiring diagram (see
section 2.6.10). Tighten the terminal block screws and ensure a good
connection.
Surface Mount Wiring
• If surface mounted cable is used the corresponding knock outs on both the
Grille Assembly and the Back Plate need to be removed to allow cable to
enter the product.
• Once cable knock outs are removed ensure that the edges of the knock
outs are dressed so that the external cable insulation is not damaged by
any sharp edges.
• Cable can now be inserted through the knock out and clamped using the
cable clamps provided.
Wiring Diagram 230V Model
Figure 2.a
25mm
5mm
C
B
A
Fuse
L
N
Light Switch
Double Pole
Isolating Switch
Fan
Terminals
N
L1
L
Light
Earth
Park