The flexible cable supplied with your appliance is designed to be connected to the mains via a junction box that must be placed behind the 
appliance.

  

In a kitchen or bathroom, the junction box must be positioned at least 25cm from the floor.

  

The appliance must be installed as described in this document and in accordance with the applicable European and local standards as well as the 
rules of good professional practice.

IMPORTANT:

 The example shown only concerns a bathtub. For other bathroom fixtures please consult your installer.

  

IMPORTANT:

 The system must be fitted with an omni-polar circuit-breaker with a minimum contact opening of 3mm.

  

To ensure your system is safe:

  

 

- ensure that an area of at least 50cm in front of the appliance is clear of objects which might hinder air circulation 

 

  (furniture, chairs etc.);

 

- position a shelf at least 10cm above the top of your radiator;

 

- use mounting screws suitable for your wall.

NOTE:

 Electric towel radiators are designed to be covered safely. However, to ensure that your appliance works efficiently, you are advised not to 

cover it completely. Doing so will increase the temperature and cause the internal cutout to turn off the appliance.

 

 

CAUTION

 

 

Always turn off the electricity supply (circuit-braker or remove the fuse before making any connections

15cm minimum

10cm minimum

Concept House
Watchmoor Point
Camberley
Surrey GU15 3AD

Tel: 
Fax: 01276 24058
retailsales@zehnder.co.uk
www.zehnder.co.uk

Registered in England: 2296696

01276 605800

Zehnder Group UK Ltd

Issue 1.0

Zehnder Pera Electric

Summary of Contents for Pera Electric PERE-080-050/F

Page 1: ...500 500 500 Width 2mm mirror mirror mirror Finish 8 12 15 Weight kg All dimensions shown are in millimetres All stainless steel construction dia 32mm x 1mm tubes dia 38mm x 1 5mm headers Connections 1 2m long flying lead 3 core Immersion heater rating IPX4 or better Output Watts 150 200 250 does not include immersion heater PERE 080 050 F PERE 120 050 F PERE 150 050 F 78 103 height 100 100 width 1...

Page 2: ...1 as long as the electrical controls are out of reach of anyone using the bath or shower The electricity supply must be protected by a residual current device with a maximum of 30mA especially when installed in a room containing a bathtub or shower WARNING This heater is not equipped with a device to control the room temperature Do not use this heater in small rooms when they are occupied by perso...

Page 3: ...is safe ensure that an area of at least 50cm in front of the appliance is clear of objects which might hinder air circulation furniture chairs etc position a shelf at least 10cm above the top of your radiator use mounting screws suitable for your wall NOTE Electric towel radiators are designed to be covered safely However to ensure that your appliance works efficiently you are advised not to cover...

Page 4: ...al Live Earth ROUTINE MAINTENANCE OPERATIONS Before carrying out any maintenance operation on your appliance ensure that it is switched off High quality materials and surface treatment protect your radiator To maximise the service life of your radiator we recommend you take the following precations to make the most of the performance of radiators containing a heat transfer fluid it is advisable to...

Page 5: ...N 60 335 2 30 and subsequent amendments Dated proof of purchase must be presented to activate the guarantee The guarantee does not cover radiator transport removal and installation costs The guarantee shall not apply if the appliance is installed used or maintained in a way that does not comply with standards in force in the relevant country good professional practice or the manufacturer s instruc...

Page 6: ... Accurately mark out bracket holes on wall using spirit level Drill four 10mm diameter holes to a minimum depth of 70mm insert wall plugs A Screw brackets B into wall plugs A with 6 3mm diameter x 60mm screws C Slide boss on radiator into bracket B and secure in position by tightening grub screw D with allen key E Electric radiators should be fitted only by a qualified electrician and must be eart...