6
USING THE VENTILATION UNIT
Once the ventilation system is carefully designed and
installed, any user actions are hardly required. The user
can relax and enjoy good ventilation.
General instructions
•
Ventilation must be sufficient.
If ventilation is not sufficient, the indoor air humidity may
rise, which can cause condensation on cold surfaces.
•
The indoor air humidity levels must be checked at
regular intervals.
During winter an indoor relative humidity level of no
more than 40-45% is recommended (room temperature
20-22°C). The relative humidity level can be checked from
the ventilation unit measurements. If the relative humidity
level rises over 45%, ventilation should be boosted.
•
The cleanliness of filters must be checked regularly.
Often in wintertime, the extract air filter collects more
dirt than the supply air filter. This means that the extract
air flow is reduced, which can lead to a rise in indoor air
relative humidity, and reduced heat recovery efficiency.
More information about cleaning and changing the filters
can be found in the
Maintenance
section.
•
Check monthly that the heat exchanger is
functioning correctly, i.e. rotating.
•
More information about checking and cleaning the
heat exchanger can be found in the
Maintenance
section.
If you encounter issues with using the ventilation
unit, check for answers in the Troubleshooting
table at the end of this manual.
Always keep the control panel in the wall mount.
Do not switch off the ventilation unless for service
or when instructed so by the authorities. The
ventilation must always be kept in operation at
the power level set at the commissioning.
FOR INFORMATION
FOR INFORMATION
FOR INFORMATION
Do not try to set the system settings by yourself!
Installing a ventilation system is a job for a trained
installer.
Do not damage the control panel screen with a
sharp or scratching object.
WARNING
WARNING
•
If the ventilation unit is shut down for a longer time
than a couple of hours during winter, the fresh air
intake vent and exhaust air blowout vent must be
covered airtight.
This prevents humidity from condensing on the electric
motors of the fans, for example.
•
In the autumn, before the beginning of the heating
season and in the spring before the beginning of the
cooling season (if the unit has a cooling function),
the condensation water drain must be checked by
pouring water in the condensation water drain and
making sure that the water drains away.
This instruction is for the users of the Enervent ventilation
unit and control panel.
Be patient! The control panel takes some time to react.