ZEISS
TECHNICAL DATA
ApoTome.2
6
423667-6044-008
09/2017
Englis
h
7
TECHNICAL DATA
Dimensions (width x depth x height)
ApoTome.2 slider for Axio Imager ..................................................... approx. 278 mm x 90 mm x 76 mm
ApoTome.2 slider for Axio Observer/Axiovert 200 .............................. approx. 295 mm x 90 mm x 78 mm
ApoTome.2 slider for Axio Zoom.V16 ................................................ approx. 278 mm x 90 mm x 76 mm
ApoTome.2 control box................................................................... approx. 255 mm x 220 mm x 96 mm
Weight
ApoTome.2 slider .............................................................................................................. approx. 1.1 kg
ApoTome.2 control box..................................................................................................... approx. 2.9 kg
Ambient conditions
Transport (in packing)
Permissible ambient temperature ........................................................................................ -40 to +70 °C
Storage
Permissible ambient temperature ......................................................................................... +5 to +40 °C
Permissible relative humidity (without condensation) ................................................ max. 75 % at +35 °C
Operation
Permissible ambient temperature ......................................................................................... +5 to +40 °C
Permissible relative humidity .................................................................................... max. 75 % at +35 °C
Air pressure ............................................................................................................ 800 hPa to 1060 hPa
Operating altitude ............................................................................................................... max. 2000 m
Pollution degree .................................................................................................................................... 2
Functional data
Area of use ......................................................................................................................... closed rooms
Protection Class ..................................................................................................................................... I
Degree of protection ....................................................................................................................... IP 20
Electrical safety ...................................................................... as per DIN EN 61010-1 (IEC 1010-1) and in
compliance with CSA and UL regulations
Overvoltage category ............................................................................................................................ II
Radio interference suppression ........................................................................... as per EN 55011 Class B
Noise immunity .................................................................................................... as per DIN EN 61326-1
Line voltage ............................................................................................................ 100 to 240 V ±10 %
Line voltage adjustment is not necessary!
Line frequency ...................................................................................................................... 50 to 60 Hz
Power consumption of ApoTome.2 ....................................................................................... max. 50 VA