Carl Zeiss
Axiotech and Axiotech
vario
2-2
B 40-020 e 06/99
2.13.1
Change of 6 V 30 W halogen lamp in the stand base (Axiotech 30 and Axiotech 100) .... 2-27
2.13.2
Connecting the 6 V 30 W halogen illuminator to the line
(Axiotech 30 and Axiotech 100)..................................................................................... 2-28
2.13.3
Change of 6 V 30 W halogen lamp (Axiotech
vario
100) ..................................................... 2-29
2.13.4
Connection of power supply for 6 V 30 W halogen illuminator (Axiotech
vario
100) ............ 2-30
List of illustrations
Fig. 2-1
Unpacking the Axiotech .................................................................................................. 2-3
Fig. 2-2
Unpacking the Axiotech
vario
............................................................................................... 2-3
Fig. 2-3
Setting up the microscope ............................................................................................... 2-4
Fig. 2-4
Axiotech
vario
- Attaching the microscope body to column X95 ............................................ 2-4
Fig. 2-5
Screw in objectives .......................................................................................................... 2-5
Fig. 2-6
Attachment of binocular tube.......................................................................................... 2-5
Fig. 2-7
Attachment of intermediate tube for image projection..................................................... 2-6
Fig. 2-8
Attachment of Optovar intermediate tube ....................................................................... 2-7
Fig. 2-9
Insertion of eyepieces ...................................................................................................... 2-8
Fig. 2-10
Change of eyecups.......................................................................................................... 2-8
Fig. 2-11
Insertion of the eyepiece reticle........................................................................................ 2-9
Fig. 2-12
Setting of eyepiece distance and viewing height of the binocular tube............................ 2-10
Fig. 2-13
Attachment of condenser .............................................................................................. 2-11
Fig. 2-14
Attachment/change of microscope stage (configuration with stage carrier A) ................. 2-12
Fig. 2-15
Attachment of adapter for stage carrier D...................................................................... 2-13
Fig. 2-16
Attachment/change of microscope stage (configuration with stage carrier D) ................. 2-13
Fig. 2-17
Attachment/change of microscope stage (stage carrier H = 140 mm) ............................. 2-14
Fig. 2-18
Specimen stage MT 50 x 50........................................................................................... 2-14
Fig. 2-19
Centering of microscope stage with maximum deflection between
object detail and eyepiece reticle ................................................................................... 2-15
Fig. 2-20
Equip filter slider and push it in beam path .................................................................... 2-16
Fig. 2-21
Change of filters in reflector slider ................................................................................. 2-16
Fig. 2-22
Setting of reflected-light luminous-field diaphragm of the Axiotech 30 ........................... 2-18
Fig. 2-23
Setting of reflected-light luminous-field diaphragm on Axiotech 100
and Axiotech
vario
100 ...................................................................................................... 2-18
Fig. 2-24
Connecting the Axiotech 30 to the line.......................................................................... 2-19
Fig. 2-25
Switching on the Axiotech 30 ........................................................................................ 2-19
Fig. 2-26
Connecting the Axiotech 100 to the line........................................................................ 2-20
Fig. 2-27
Connecting the Axiotech
vario
100 to the line via separate power unit................................ 2-21
Fig. 2-28
Change of 6 V 30 W halogen lamp................................................................................ 2-22
Fig. 2-29
Attachment of 12 V 100 W halogen illuminator ............................................................. 2-23
Fig. 2-30
Alignment of 12 V 100 W halogen lamp........................................................................ 2-24
Fig. 2-31
Change of 12 V 100 W halogen lamp............................................................................ 2-25
Fig. 2-32
Change of 6 V 30 W halogen lamp (Axiotech 30 and Axiotech 100)............................... 2-27
Fig. 2-33
Connecting the 6 V 30 W halogen illuminator to the line (Axiotech 30
and Axiotech 100)......................................................................................................... 2-28
Fig. 2-34
Change of 6 V 30 W halogen lamp (Axiotech
vario
100) .................................................... 2-29
Fig. 2-35
Connection of power supply for 6 V 30 W halogen illuminator (Axiotech
vario
100) ............ 2-30
Summary of Contents for Axiotech
Page 1: ...Axiotech and Axiotechvario Materials Microscopes Operating Manual...
Page 14: ...Carl Zeiss Axiotech and Axiotechvario XIV B 40 020 e 06 99...
Page 16: ...Carl Zeiss Axiotech and Axiotechvario 1 2 B 40 020 e 06 99...
Page 112: ...Carl Zeiss Axiotech and Axiotechvario 3 46 B 40 020 e 06 99...
Page 114: ...Carl Zeiss Axiotech and Axiotechvario 4 2 B 40 020 e 06 99...
Page 124: ...Carl Zeiss Axiotech and Axiotechvario A 2 B 40 020 e 06 99...