12
6. Press the option: Engine Runs hyst.
7. First, the upper voltage limit is requested, this is the value at which the
Zeliox Compact begins to charge. The value to be entered is V idle - 0.2.
For example, V idle = 14.4V then the value to be entered is 144 (period
is added automatically). Type the value and exit with enter.
8. Then the lower voltage limit is requested, this is the value at which
the Zeliox Compact stops charging again. The value to be entered is
V b 0.5. For example if V battery = 12.7V then the value to be
entered is 127 (period is added automatically). Enter the value and exit
with enter. The lower limit MUST be lower than the upper limit, if not,
the procedure starts again.
9. Now press the arrow to the left twice (bottom left), The Zeliox Compact
now asks if the changes should be rejected (discard changes),
press NO.
10. Changes are now saved and the engine running function can be tested.
Summary of Contents for ZEL16-1,2-EU
Page 1: ...User Installation Manual Zeliox Compact ENGLISH...
Page 6: ...6 User Manual Zeliox Compact ENGLISH...
Page 25: ...25 Installation Manual Zeliox Compact ENGLISH...
Page 46: ...46 Notes...
Page 47: ...47 Notes...
Page 48: ...48 Zeliox BV Spaarpot 13 5667 KV Geldrop The Netherlands www zeliox com...