43
7.1.8
Over voltage main battery
Full message:
Low voltage / Please Charge (orange)
Means:
An over voltage has been measured on the main
battery. Contact Zeliox.
Action:
Error message and activities are stopped
7.1.9 Cell anomaly
Full message:
Cell Anomaly / Contact Zeliox (orange)
Means:
One or more of the cells is used out of specs.
Contact Zeliox
Action:
Error message and Zeliox will continue
7.1.10
Low main battery voltage but charger active
Full message:
Low voltage / Charger Active (white)
Means:
The main battery voltage has reached the lower
threshold, but charger is active. Message will disappear
as soon the threshold is reached.
Action:
Error message and Zeliox will continue
7.1.11 Battery protection Mode
Full message:
Bat. Protection on / Inverter/12V Off (orange)
Means:
This is the latest message the user will get before the
Zeliox will switch off
Action:
Error message. Zeliox will switch off all outlets
and continue displaying this error until it switches
completely off
7.1.12
No BMS active or present
Full message:
No BMS / Using analog (white)
Means:
The Battery management System is not active
Action:
Warning message. Zeliox will switch over to a
redundant analog but less advanced system.
No charging possible! Contact Zeliox ASAP.
7.1.13 Isolation fault occurred
Full message:
ISO FAULT. Please / restart (orange)
Means:
An isolation fault occurred
Action:
Error message and activities are stopped (no output
and input), user needs to switch off and on the Zeliox
to de-assert the isolation fault
Summary of Contents for ZEL16-1,2-EU
Page 1: ...User Installation Manual Zeliox Compact ENGLISH...
Page 6: ...6 User Manual Zeliox Compact ENGLISH...
Page 25: ...25 Installation Manual Zeliox Compact ENGLISH...
Page 46: ...46 Notes...
Page 47: ...47 Notes...
Page 48: ...48 Zeliox BV Spaarpot 13 5667 KV Geldrop The Netherlands www zeliox com...