25
2.3 Disassembly of the stand with balance type 481.1500 (Fig. 4)
Turn the interlock knob
17
to the
OFF
position and turn around the stand with the scale base
15
facing upwards. Remove the battery cover
18
and take out the batteries.
Remove the two screws
28
together with the spring washers
25
.
Pull back the scale base
15
, taking care not to break off the wires connecting the sensor cpl.
22
with the electronic plate with a display
24
.
Pull out the plug of wires of the sensor cpl.
23
from the electronic plate
24.
Squeezing the catches of the sleeve protruding from the scale base
15
, remove the interlock
knob
17
and the interlock fork
16
.
Pull out the plug of wires of the battery container
23
from the electronic plate
24
.
Push in the catches of the electronic guard
19,
and then by means of a screwdriver prize the
guard up at the bottom of the scale base and remove the guard (taking care not to damage
the sockets in the electronic plate and not to bend the guard catches while pushing in).
Remove the electronic plate with a display
24
.
Remove the battery container micro-switch
23
from the pins of the scale base
15
(Fig. 6)
,
and
then remove the battery container from the scale base (take care not to pull off the wires).
Pull back the three catches protruding from the scale base
15
(at the side of the interlock
knob
17
) and remove the metal cover
21
.
Remove the six supports
13
from the scale base
15
(prize them up with a screwdriver, if
necessary).
Remove the four screws
27
from the base
1
in order to remove the second metal guard
21
.
Separate the sensor cpl.
22
from the metal guard
21
by removing the two screws
28
together
with the spring washers
25
.
Carry out further disassembly steps according to the disassembly of
stand with bowl
type
481.1000
(page 24).
Note:
The decorative foil
20
is glued to the scale base 15 once only and after the
stripping it needs to be renewed.
Note:
In the case of damage to the electronic plate
24
or sensor cpl.
22
, replace both
parts which are available as Electronic PCB cpl. 481.1530 (they must be replaced
as a complete unit in order to work correctly).
2.4 Disassembly of the motor type 252.1000 (Fig. 5)
Pull off the clutch
16
from the end of the rotor
1
. Unsolder the chokes
17
from the brush
frames
18
and disconnect them from the stator
2
.
Unbend the plugs of the brush frames
18
, remove the brush springs
20
and the brushes
19
.
Remove the brush frames
18
from the bearing disc
4
.
Remove the screws
21
, remove the wheel interlock
15
, remove the gear wheel
14
.
Remove the screws
22
. Remove the gear housing
3
from the stator
2
.
Remove the rotor
1
from the stator
2
and the bearing disc
4
. Remove the washers
8,9,8
from
the rotor
1
, and remove the ball
7
from the rotor shaft
1
.
Remove the bearing disc
4
from the stator
2
. Remove the bearing clamp
6
and the bearing
5
from the bearing disc
4
.
Remove the wheel interlock
13
from the sockets of the gear housing
3
, and remove the thrust
bearing in the form of resist washer
11
, paper insert
12
and felt
10
.
Remove the bearing clamp
6
and the bearing
5
from the gear housing
3
.
Note:
The spring washer
9
and the bearing clamp
6
are single-use items.
Summary of Contents for 481.4
Page 3: ...3 Napęd miksera typ 481 0000 Mixer drive type 481 0000 Rys 1 ...
Page 5: ...5 Wyposażenie miksera Mixer equipment Rys 2 ...
Page 9: ...9 Stojak z wagą typ 481 1500 Stand with balance type 481 1500 Rys 4 ...
Page 13: ...13 Kruszarka z minimalakserem typ 481 0400 Ice crusher with mini food processor type 481 0400 ...