background image

 

FIRE HAZARD 

KEEP ALL FLAME AND OTHER HEAT SOURCES 
AWAY FROM THE FLOAT TANK, INCLUDING THE 
TANK FABRIC. THE FABRIC MAY BURN OR MELT 
IF PLACED IN CONTACT WITH ANY FLAME OR 
OTHER HEAT SOURCE. 
 
 

DRUGS AND ALCOHOL USE 

DO NOT USE DRUGS OR ALCOHOL BEFORE OR 
DURING USE OF THE FLOAT TANK. THE USE OF 
DRUGS OR ALCOHOL MAY INCREASE THE RISK 
OF INJURY, UNCONSCIOUSNESS, AND POSSIBLE 
DROWNING. 

 

 

SLIPPING AND FALLING 

TO AVOID FALLING OR OTHER INJURY, USE 
CAUTION WHEN ENTERING OR EXITING THE 
FLOAT TANK. 
 

CHILDREN 

THE FLOAT TANK SHOULD NOT BE USED BY 
CHILDREN UNDER THE AGE OF 12. CLOSELY 
WATCH ALL CHILDREN IN AND AROUND THE 
FLOAT TANK, AND NEVER LEAVE ANY CHILD 
UNATTENDED INSIDE THE FLOAT TANK OR WITH 
ACCESS TO THE FLOAT TANK. IT IS 

RECOMMENDED THAT ALL DOORS AND WINDOWS TO THE ROOM 
CONTAINING THE FLOAT TANK REMAIN LOCKED TO LIMIT ACCESS. 
 
 
 
 
 
 

Summary of Contents for Tank

Page 1: ...ZEN FLOAT TANK TM ASSEMBLY INSTRUCTIONS VIDEO INSTRUCTIONS https www youtube com zenfloatco Version 2 5 updated 09 31 2020 For help with watercare maintenance go to zenfloatco com water care 1 ...

Page 2: ...RM THAT FLOOR LOAD BEARING CAPACITIES ARE ABLE TO SUPPORT THE FLOAT TANK WEIGHT WHEN FILLED AND OCCUPIED CALCULATE AT APPROXIMATELY 75 LBS 34 KG PER SQUARE FOOT WHICH IS BASED ON A HUMAN FLOATING IN THE TANK THAT WEIGHS UP TO 300 LBS TOTAL FLOAT TANK WEIGHT WITH WATER AND SALT IS APPROXIMATELY 2200 LBS 998 KG TEMPERATURE ALWAYS CHECK YOUR TEMPERATURE BEFORE GETTING INTO THE FLOAT TANK DO NOT EVER ...

Page 3: ...INCREASE THE RISK OF INJURY UNCONSCIOUSNESS AND POSSIBLE DROWNING SLIPPING AND FALLING TO AVOID FALLING OR OTHER INJURY USE CAUTION WHEN ENTERING OR EXITING THE FLOAT TANK CHILDREN THE FLOAT TANK SHOULD NOT BE USED BY CHILDREN UNDER THE AGE OF 12 CLOSELY WATCH ALL CHILDREN IN AND AROUND THE FLOAT TANK AND NEVER LEAVE ANY CHILD UNATTENDED INSIDE THE FLOAT TANK OR WITH ACCESS TO THE FLOAT TANK IT IS...

Page 4: ...TTENDED WHEN FILLING WITH WATER BE AWARE THAT WATER RISES AS YOU ENTER THE FLOAT TANK AVOID USING SHARP OBJECTS WHEN NEAR THE FLOAT TANK AS THIS COULD PUNCTURE THE FLOAT TANK AND CAUSE FLOODING ALWAYS DRAIN THE FLOAT TANK AS DIRECTED BEFORE MOVING THE FLOAT TANK TO PREVENT FLOODING ALWAYS DETACH THE TANK FROM THE TUB BEFORE DISASSEMBLING THE TANK NEVER PULL ON THE TANK TO REMOVE POLES SUITABLE INS...

Page 5: ...SHOULD NOW OPERATE NORMALLY WHEN THE PRODUCT FAILS TO OPERATE IN THIS MANNER THERE IS A GROUND CURRENT FLOWING INDICATING THE POSSIBILITY OF AN ELECTRICAL SHOCK DISCONNECT THE POWER UNTIL THE FAULT HAS BEEN IDENTIFIED AND CORRECTED D IF THE UNIT WAS NOT PROVIDED WITH A GFCI IT MUST BE WIRED BY A CERTIFIED ELECTRICIAN FAILURE TO DO SO COULD RESULT IN SERIOUS BODILY INJURY OR DEATH AND WILL VOID ALL...

Page 6: ...lace during shipping and all listed items are included If you have any concerns please contact our support team before starting assembly 1 x Air Inflation Pump 1 x Base Drip Mat 1 x Tank Body 1 2 3 2 x Heating Pads 15 x Foam Tiles 1 x Temperature Controller Grounding Probe pre plugged inline 4a 4b 5 6 6 ...

Page 7: ...nding Probe Pre plugged to Temperature Controller 1 x GFCI Adapter 120V models only 7a 7b 8 9 1 x Filter Bag Additionals incl w Float Ready Package 1 x T Fitting Pre inserted in Filtration Hose 1 x 90 Degree Fitting Pre inserted in Filtration Hose 10 11 12 7 ...

Page 8: ...d 4 x Vent Caps 1 x Pump Manifold Pre assembled with Water Pump Fittings 13 14 15 1 x Hydrometer 1 x Inline Carbon Filter 1 x Water Test Strips Additionals incl w Float Ready Package 16 17 18 1 x Step Drip Mat 1 x Air Valve Wrench 1 x Repair Kit 19 20 21 8 ...

Page 9: ...e a preferred location that will stay between 70 and 90 Fahrenheit 21 to 32 Celsius Allow at least 1 ft 30 cm of space between the Float Tank and the room s walls to allow for maintenance and cleaning Consider the space between the front door side of the Float Tank and the wall to allow for entering and exiting 1 Interlock the Foam Tiles 5 in a 3 x 5 configuration a You may need to rotate the tile...

Page 10: ...DE UP 1 Place Heating Pads 4a 4b on top of the Foam Tiles 5 a Inside edges of the Pads should touch but not overlap 2 This Side Up sticker identifies proper side is facing up 3 Orient Heating Pads 4a 4b on top of the Foam Tiles 5 so the electrical cords face the rear side of the Tank opposite the Door Side 4 Pads will be located toward the rear edge of the foam tiles 10 ...

Page 11: ...ady pre plugged into it c Either Heating Pad plug can be used for either of the two available Temperature Controller plugs operation is not affected by this selection Properly functioning Heating Pads will quickly become hot to the touch in 4 to 5 zones Do not leave Heating Pads plugged into the wall outlet for more than 30 seconds without water in the Tank If a Heating Pad does not heat up please...

Page 12: ...n the end cap on the oral air inflation tube 2 Position the Base Drip Mat 2 over the Foam Tiles 5 and the Heating Pads 4a 4b Step 4 INFLATE PLACE TANK BODY There are seven different air valves on the Float Tank Body you will need to inflate to complete the process Left wall valve 1 Right wall valve 2 Rear wall valve 3 Lower front wall valve 4 Door frame valve 5 Door valve 6 Door Inside Valve 7 1 A...

Page 13: ... trapped under the air valve protective cap 7 Place the Tank Body 3 on the Drip Mat 5 by lining up the Tank Body over the Heating Pads 4a 4b 8 Allow the Tank to sit for 24 hours as the panels may stretch check the panels after 24 hours and add pressure as needed TIP Each valve has a pin in the center that can be manually pushed down to quickly deflate the walls If you push down and turn the pin cl...

Page 14: ... on the inside of the air holes is recommended some owners prefer installing two inside and two outside but this can lead to condensation gathering outside of the Tank 1 Insert three of the four tabs on the base of a Vent Cap 5 into an air hole on the back inside wall of the Tank 2 Use a finger to tuck the fourth tab into the air hole to secure the Vent Cap 3 Repeat this process for all Vent Cap i...

Page 15: ...a 7b Water Pump UV Water Filter 10 Filter Bag 11 T Fitting 12 90 Degree Fitting 13 Water Filtration Hoses 1 Set the Water Pump and UV Water Filter 7a 7b in the back left corner of the Tank 2 Screw the Pump Manifold 15 the top of the the Water Pump 7a 15 ...

Page 16: ...Tank 6 Connect the Water Filtration Hoses 13 together with the T Fitting 11 7 Fit Filtration Hoses 13 between the C clips located on the left interior wall to securely install them in place a C clips can become twisted during shipping but can be gently manipulated to accept the Filtration Hoses 13 b The Filtration Hoses 13 will be curved and ridged when you receive and install it but will relax af...

Page 17: ...allons 20 liters of water through the Inline Carbon Filter 17 into a drain or until water runs clear to make sure no excess carbon from the Inline Carbon Filter is deposited into the Tank 3 Add 3 inches 7 5 cm of water to the Tank a Only use non heated tap temperature water 4 Smooth out creases on the tub floor as much as possible 17 ...

Page 18: ... Epsom salt into the water d As the Epsom salt dissolves the water temperature will lower due to an exothermic reaction 7 Add and mix all 800 lbs 363 Kg of Epsom salt into the 4 inches of water 10 cm a The water level will rise as more Epsom salt is added 8 Continue filling with water level until 9 inches 23 cm of depth is reached a Hot water can be used at this stage and will help the Tank reach ...

Page 19: ...oller 6 a There are two available plugs from the Temperature Controller 6 and one will have the Grounding Probe 8 already pre plugged into it b Either Heating Pad plug can be used for either of the two available Temperature Controller plugs operation is not affected by this selection 3 Insert the Grounding Probe 8 into the Tank through the access port 4 Submerge the Grounding Probe 8 and insert th...

Page 20: ...should now be circulating through the filtration system and a slight glow should be coming from the UV Water Filter 7b The Temperature Controller display will now display a temperature detected by the attached temperature sensor For safety the Tank s water should be electrically grounded Please contact a licensed electrician if you have any questions or concerns about your home s electrical system...

Page 21: ...nd middle buttons to adjust 2 To change the setting to Celsius hold the top and middle up and down buttons simultaneously for three seconds 3 Set the temperature to 93 5 F 34 C to start a This is the average temperature used by floaters and a good starting point 4 Anticipate the temperature rising approximately 1º F 1 2º C per hour 21 ...

Page 22: ...ghtened through forceful turning of the valve cap If there is a slow air leaking in one of your panels use the provided Air Valve Wrench 20 to adjust the air valve following these steps Deflate the affected panel With one hand hold the backside of the air valve from the inner side of the Tank panel Place the Air Valve Wrench 20 Turn the Air Valve Wrench 20 clockwise Test for leaks after adjusting ...

Page 23: ...Zen Float Co 5947 S 350 W Murray UT 84107 USA Tel 801 871 5140 Email info ZenFloatCo com 23 ...