background image

Installation and User Guide  

 
Document Ref.: U-0769-0001 - ECP-C1_v01 
Issue: 01c Complete / Approved Date: 15/01/2024 
Product Part Number: 1008195005 
 

 

 

 

 

ECP-C1 

Single Button Emergency Call Point with Built in AFIL 

Hearing Loop 

 

 

 

 

Summary of Contents for ECP-C1

Page 1: ...lation and User Guide Document Ref U 0769 0001 ECP C1_v01 Issue 01c Complete Approved Date 15 01 2024 Product Part Number 1008195005 ECP C1 Single Button Emergency Call Point with Built in AFIL Hearin...

Page 2: ...owing EC Directives for electrical and electronic equipment 1 Restriction of Hazardous Substances RoHS Directive 2011 65 EU 2 Electromagnetic Compatibility EMC Directive 2014 30 EU 3 Low Voltage LVD D...

Page 3: ...e 01 Complete Approved Page 3 of 29 Contents 1 Safety and Precautions 4 2 Overview 5 3 Preparation 6 4 Unpacking and Handling 7 5 Installation 9 5 1 Cable Entry and Gland Points 9 5 2 Connectivity 10...

Page 4: ...t altitudes exceeding 2000 m The ECP C1 should not be used in tropical environments The ECP C1 must not be installed in an area that is subject to a corrosive atmosphere or may allow water or other li...

Page 5: ...ange of commercial telephony systems and telephone Private Branch Exchange PBX products The ECP C1 only requires a single external connection due to the inclusion of a Power over Ethernet PoE power su...

Page 6: ...in Section 1 Safety and Precautions on page 4 Failure to follow these instructions and guidelines may cause personal injury and or damage to the equipment 2 Gather the following documentation and tool...

Page 7: ...te assembly Including all electronic items o Painted stainless steel back box assembly Three cable entry blanking plugs fitted o Six off stainless steel tamper resistant security screws Securing the f...

Page 8: ...s returning for service 6 If the packing is not to be retained the packing materials should be either recycled or disposed of according to local regulations 7 Ensure that the name and address of the A...

Page 9: ...oint s back box by means of a pair of 25mm cable gland positions in the rear of the back box plus another pair of cable gland positions in the bottom face of the back box 1 The help point s Ethernet c...

Page 10: ...nection point 5 3 Optional Connectivity In addition to the standard functionality which is described in this manual it is possible to configure additional features of the ECP C1 s Zenitel intercom mod...

Page 11: ...rnet connection cable should be flexible enough to enable the help point to be assembled without excessive strain being placed on the RJ45 input socket for the AFIL Hearing Loop s PoE power supply 4 O...

Page 12: ...ECP C1 Installation and User Guide U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 12 of 29 Front and side views of the ECP C1 front assembly and back box assembled as for surface mounting...

Page 13: ...Complete Approved Page 13 of 29 ECP C1 back box dimensions showing four off 5 5mm rear mounting holes The image also shows the four off optional positions for fitment of 25mm cable glands or conduit...

Page 14: ...mounting surface Provision of a flush front panel is dependent on a suitable mounting surface thickness or appropriate bevel to match the thickness of the help point s stainless steel front plate and...

Page 15: ...ECP C1 Installation and User Guide U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 15 of 29 Oblique front view of the ECP C1 front assembly and back box with mounting adaptor plate fitted...

Page 16: ...v01 Issue 01 Complete Approved Page 16 of 29 ECP C1 flush mount adaptor plate dimensions showing the six off 4 5mm countersunk mounting holes The image also shows the four off countersunk holes for th...

Page 17: ...ser Guide U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 17 of 29 6 Configuration See the Zenitel Turbine series intercom information in the Turbine IP Intercom s technical manual A100K11194 f...

Page 18: ...U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 18 of 29 7 Operation 7 1 Front Panel ECP C1 front panel Loudspeaker LED Indication From left to right 1 Calling 2 In Call 3 AFIL Hearing Loop Ac...

Page 19: ...onse Centre operator ends the call 1 The help point will return to its idle state silent and with all three LEDs unlit 7 3 Push To Talk Mode In some cases the ECP C1 may be configured to operate in Pu...

Page 20: ...er Guide U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 20 of 29 8 Connections ETH1 100 1000BASE T Ethernet Port Cabling Type Standard LAN cable CAT5e minimum Power POE Termination RJ45 Sugges...

Page 21: ...Output Current sine 3 1A RMS Loop Impedance 0 3 to 1 1 3 reactive at 1 6kHz Loop Frequency 100Hz to 5kHz 1 5dB Metal Loss Correction 0dB to 3dB octave boost Environmental Temperature Operational 25 C...

Page 22: ...Operation HTTP HTTPS Web configuration DHCP and static IP IC EDGE Remote automatic software upgrade Centralized monitoring LAN Control Network Access Control IEEE 802 1x Protocols IPv4 with DiffServ...

Page 23: ...ECP C1 Installation and User Guide U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 23 of 29 10 Mechanical Dimensions Back Box...

Page 24: ...g the type of service required return address equipment type and full serial number If the original packing can no longer be used the following general instructions should be used for repacking with c...

Page 25: ...ECP C1 Installation and User Guide U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 25 of 29 13 Appendix 13 1 Internal Wiring Diagram...

Page 26: ...ECP C1 Installation and User Guide U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 26 of 29 Notes...

Page 27: ...ECP C1 Installation and User Guide U 0769 0001 ECP C1_v01 Issue 01 Complete Approved Page 27 of 29 Notes...

Page 28: ...rd 8 Modification to the unit or inexpert attempted repair 9 No fault found where no fault can be found after extensive testing indicating user error or failure in ancillary equipment 10 Electronic as...

Page 29: ......

Reviews: