2.4
POWER
The operating power is 115/230 VAC as primary, and 24VDC as backup. The MPA 1600 system will
automatically switch between primary and secondary power source in case of mains failure. The
24VDC must be permanently present for mains transaction backup supply in order to avoid the system
boot sequence of approximately 30 seconds. The system is unavailable for operation during the boot
sequence.
As an optional safety precaution, the mains operating power may be pre-switched by means of a
mechanical contactor/switch-over module as long as the 24VDC backup supply is present to keep the
system from power fail during the switching period.
2.5
GLANDS
The cables enter the WP units by means of cable glands. Where cable glands are not supplied from
factory, the installer must adapt the glands to the actual cable outer diameter. This is to obtain the
specified inlet protection.
2.6
FERRULING
The conductors should be ferruled prior to termination onto the screw terminals.
2.7
MARKING
Each cable is to be marked with cable numbers.
Each conductor is to be marked with the specific termination numbers.
2.8
FASTENING
Where applicable, the cables and the conductors shall be clamped to the structure with cable ties.
2.9
PRESERVATION
Prior to, during, and after installation the equipment must be handled with care. And protected against
acid holding fluids, pollution, moist, impacts etc.
This is in order to avoid damaged equipment, for which
Zenitel
will claim void warranty.
Handbook page
32 of 89
Summary of Contents for Phontech MPA 1600 Series
Page 1: ...USER HANDBOOK MPA 1600 MARITIME COMMUNICATION SYSTEMS...
Page 2: ......
Page 28: ...Doc No 03118 000 IS Page 5 of 12 DNH CAR6T Fig 2 1 Handbook page 26 of 89...
Page 29: ...Doc No 03118 000 IS Page 6 of 12 DNH HP15T Fig 2 2 Handbook page 27 of 89...
Page 44: ...Handbook page 42 of 89...
Page 45: ...Handbook page 43 of 89...
Page 46: ...Handbook page 44 of 89...
Page 47: ...Handbook page 45 of 89...
Page 48: ...Handbook page 46 of 89...
Page 49: ...Handbook page 47 of 89...
Page 50: ...Handbook page 48 of 89...
Page 51: ...Handbook page 49 of 89...
Page 52: ...Handbook page 50 of 89...
Page 64: ...Handbook page 62 of 89...
Page 65: ...Handbook page 63 of 89...
Page 66: ...Handbook page 64 of 89...
Page 67: ...Handbook page 65 of 89...
Page 68: ...Handbook page 66 of 89...
Page 69: ...Handbook page 67 of 89...
Page 70: ...Handbook page 68 of 89...
Page 71: ...Zenitel AS Handbook page 69 of 89...
Page 89: ...PHONTECH Communication Systems Power Amplifier 1670 MARITIME COMMUNICATION SYSTEMS...