Read These Warnings First

Please read all installation requirements, installation procedures and 
precautions before installing any Zenith Autoboil instant boiling water heater.

Never attempt to install any Zenith Autoboil instant boiling water heater without 
reading all of the applicable instructions.

In some hard water areas where mineral scale accumulation in the boiling 
chamber of the Zenith Autoboil may become a problem, consideration should 
be given to the maintenance required. A suitable form of water treatment may 
be necessary.

All plumbing connections must be made in accordance with local regulations.

The Zenith Autoboil instant boiling water heater is not intended for use by 
young children or infirm people without supervision. 

Young children should be prevented from having access to ensure that they are 
not able to use or play with the heater.  

If the installation site is located more than 1000 meters above sea level, the 
installer should contact a Zenith authorised agent for high altitude settings.

This appliance must be earthed. If the power supply cord is damaged it must 
be replaced by a Zenith authorised agent or a qualified electrician. 

Do not remove the cover of the heater under any circumstances without first 
isolating the heater from the power supply.

Do not use strong, corrosive or abrasive cleaners to clean the case of the 
heater.

Frost protection: If this heater is located where ambient air temperature could 
fall below 5ºC when the heater is not in use, do not turn off the appliance 
electrically. This safeguard does not offer the same protection to the 
connecting pipework and fittings.

The ambient temperatures this unit must operate within is 5ºC - 50ºC.

This heater is intended only for indoor use and should never be installed 
outdoors or be exposed to the elements of nature.

This unit must not be positioned in an area that may be cleaned by a water jet. 
This unit must not be cleaned by a water jet.

Before installing, ensure that the following are available:

a)  Sufficient space to position the heater so there is at least 150 mm  

 

clearance above the heater for service access,65 mm to its left and 
20 mm to its right – the tap outlet usually should be positioned at least 
200 mm above a draining board or drip tray.

b)  Standard local requirement power cable positioned as shown on the  

paper mounting template for connection from the rear of the heater to 
the terminal block within the heater, OR a standard power outlet that will 
adequately cater for the unit’s power needs on the wall within 1500 mm of 
the heater. For units with 3.6 Kw element (25 ltr) or multi element units (40 
ltr) an isolating switch in the fixed wiring and attached to a secure surface 
is required. 

c)  Cold water supply with a minimum working pressure of 1 bar (100 kPa) 

and a maximum working pressure of 7 bar (700 kPa) connected via an 

Installation Requirements

Summary of Contents for Autoboil 01652

Page 1: ...Instructions 81433 June 2012 v1 01 Page1 of 12 Installation and Operating Instructions Autoboil Instant boiling water 01652 Autoboil 1 5 Litre White 03652 Autoboil 3 0 Litre White 05652 Autoboil 5 0...

Page 2: ...Page 2 of 12 Zenith Autoboil Installation Operating Instructions 81433 June 2012 v1 01 Intentionally left blank...

Page 3: ...5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Wall Mounting Template Dimensions Electrical Diagram 7 Problem Solving 8 Ea...

Page 4: ...t use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater is not in use...

Page 5: ...aining board or drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for...

Page 6: ...or concealed vent plumbing connect plumbing to the vent outlet from the heater rear using a capillary elbow protruding 45 mm from the wall Alternatively attach a tun dish to the wall as shown and plum...

Page 7: ...ing Template Dimensions Electrical Diagram 1 5L 3 0 L 5 0 L 7 5 L 65 CLEAR 56 COLD INLET 72 15 25 35 42 POSITIONING PIN VENT EXTERNAL PLUMBING ELECTRICAL WIRING POSITION INTERNAL PLUMBING BENCH TOP 31...

Page 8: ...th authorised agent Warning this appliance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified technician using an appliance tester or conti...

Page 9: ...ing water will flow until the tap handle is released This operation gives fingertip flow control for safe filling of cups and mugs To fill larger vessels such as teapots and saucepan s rotate the tap...

Page 10: ...rload kit Autoboil 2000B 14 90501NZ Tap Top Kit Autoboil 2000B 15 90562NZ Tap Assy complete 2000B 16 90503NZ Strap and key kit 1 5 3L 2000B 16 90504NZ Strap and key kit 5 7 5L 2000B 17 90505NZ Tap nut...

Page 11: ...Zenith Autoboil Installation and Operating Instructions 81433 June 2012 v1 01 Page11 of 12 Spare Parts...

Page 12: ...tallation should it become necessary to service the appliance under the terms of Zenith Heaters Limited warranty To register your installation go to www zenithheaters co nz and look under the heading...

Reviews: