Page 20 of 36
802253NZ - HydroTap BC, BCHA-AV, AIO, Installation Instructions - Aug 2015 - V2.01
1.18
Installation Instructions
CLAMP
BLOCK
•
Screw the braided hoses
into the extension tubes.
Ensure the o-rings
are lubricated prior to
assembly and that the
braided hoses, with
coloured markings,
are correctly matched
with the colours on the
extension tubes and
on the clamp block (as
indicated).
•
Make sure all tubes and
hoses are firmly secured.
Braided
hoses
Vented
braided hose positions
Mains
braided hose positions
BLUE to
Mixer IN
HOT IN
from HWS
WHITE
Mains IN
RED from
Mixer OUT
Underside view
BLUE
Mains IN
RED
Extension
tubes
Typical Vented assembly
External HOT & COLD
isolation valves
(Not supplied)
Tee piece
(supplied)
Typical All-in-One Mains Installation (See section 4)
1.19
Note:
All
silicon tubes
must be cut to
size. They must
have a constant
fall back to the
unit.
Note:
- Mains hose
length is 750mm
- Plug and Cord
length is 1800mm
Position the under
sink unit close
to the outlet tap,
within reach of
the hose and cord
lengths supplied