background image

26

Quick Start Installation Guide

 

807119NZ v1.00 01.21 G5 BCS Quick Start Guide

SECTION 13: Connect the Command Centre

USB

CO

2

IN

CHILLED

OUTLET

SPARKLING

OUTLET

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

CHILLED

OUTLET

SPARKLING

OUTLET

CO

2

IN

USB

BCS comm

BCS res

BC comm

CHILLED

OUTLET

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

USB

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

CHILLED

OUTLET

USB

BC res

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

AMBIENT

OUTLET

USB

BA res comm

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

B res comm

USB

MAINS

IN

C 175  comm

USB

CHILLED

OUTLET

CS 175  comm

CO

2

IN

CHILLED

OUTLET

SPARKLING

OUTLET

MAINS

IN

C res

CHILLED

OUTLET

MAINS

IN

USB

CS75  res

CO

2

IN

CHILLED

OUTLET

SPARKLING

OUTLET

MAINS

IN

USB

check USB 

position

check which way round 

still / sparkling

USB

CO

2

IN

CHILLED

OUTLET

SPARKLING

OUTLET

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

CHILLED

OUTLET

SPARKLING

OUTLET

CO

2

IN

USB

BCS comm

BCS res

BC comm

CHILLED

OUTLET

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

USB

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

CHILLED

OUTLET

USB

BC res

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

AMBIENT

OUTLET

USB

BA res comm

MAINS

IN

MIXER 

OUT

MIXER 

IN

BOILING

OUT

BYPASS

IN

VENT

BYPASS

OUT

B res comm

USB

MAINS

IN

C 175  comm

USB

CHILLED

OUTLET

CS 175  comm

CO

2

IN

CHILLED

OUTLET

SPARKLING

OUTLET

MAINS

IN

C res

CHILLED

OUTLET

MAINS

IN

USB

CS75  res

CO

2

IN

CHILLED

OUTLET

SPARKLING

OUTLET

MAINS

IN

USB

check USB 

position

check which way round 

still / sparkling

 Mains 

Water

 

!

BCS20, BCS30, 

BCS Home models

Zenith 

Vented 

Mixer Tap 

connections 

(if supplied)

Fit foam insulation  

(supplied) to the 

BLUE and WHITE pipes

BCS Compact

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

 

III

III

II

II

II

II

IIIIIIIIII

II

II

Example installation

BLUE WHITE

RED

Diagram for illustrative purposes only.

Optional 

limescale filter

Bo

ost

er

Lime

-

sc

ale 

Filt

er

CLEAR

Booster (selected models) and 

limescale filter (optional)

Summary of Contents for HydroTap G5 BCS100

Page 1: ...on Guide 807119NZ v1 00 01 21 G5 BCS Quick Start Guide 1 Zenith HydroTap G5 Quick start installation guide Command Centre Boiling Chilled Sparkling models AFFIX PRODUCT LABEL HERE Visit our website to...

Page 2: ...S REGULATORY INFORMATION 6 SECTION 4 Technical data 8 SECTION 5 Parts supplied consumables and accessories 10 SECTION 6 Set up the ventilation 11 SECTION 8 Connect the water supply 15 SECTION 9 Set th...

Page 3: ...stalling and operating your HydroTap download read the Command Centre installation and user instructions which can be found online at zenithwater co nz Read and use the instructions supplied with indi...

Page 4: ...credited service provider or qualified refrigeration technician Keep ventilation openings in the appliance enclosure or in the built in structure clear of obstruction Do not use mechanical devices or...

Page 5: ...s To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting Somet...

Page 6: ...or clean with water jets Do not expose the Zenith HydroTap to the elements of nature The booster complies with protection class IP 20 For UK a pressure limiting valve must be fitted for mains water pr...

Page 7: ...e appliance ensure the power supply cord is not trapped or damaged If the power supply cord is damaged it must be replaced by a Zenith service provider or a qualified electrician Do not locate multipl...

Page 8: ...H 2 15 2 20 450 500 x 470 x 333 41 BCS60 BCS60 H 2 15 450 500 x 470 x 333 41 BCS30 BCS30 H 1 96 2 20 339 x 460 x 333 34 BCS20 BCS20 H 1 96 339 x 460 x 333 34 BCS Home BCS H Home 1 53 339 x 460 x 333...

Page 9: ...g UK have an internal pressure limiting device to reduce the maximum mains regulated pressure 700kPa in NZ Australia protecting the system against pressure surges above 500kPa Component Min Max pressu...

Page 10: ...Mains mixer Tap instructions Optional Optional Command Centre Command Centre Mains electrical supply cable Water supply inlet hose Water supply inlet adaptor and strainer Ventilation kit including ven...

Page 11: ...ntilation Command Centre width A clearance envelope around all Command Centres must be provided to allow ventilation for the safe and effective use of the HydroTap system 200mm 50mm 50mm Use instructi...

Page 12: ...gas in the unlikely event of a leak 4mm door buffers supplied Cold air is drawn in through the inlet vent and gap provided by the door buffers Inlet vent is mounted over cupboard side door or floor cu...

Page 13: ...ntilation is required Contact your Zenith service provider for options including additional vents and fan kit All models Cold air is drawn in through the inlet vent and lower gap provided by the door...

Page 14: ...time which will help in your flow rate setup Multiply the amount of water dispensed in 15 seconds by 4 to determine the flow rate in litres per minute The optimum flow rate is 1 6 litres per minute 4...

Page 15: ...not included Strainer supplied Male Female adaptor supplied Connect together Connect to Command Centre see pages 25 26 Note Mixer tap installations also use a tee piece as part of the water supply pl...

Page 16: ...filter Water in Bypass out see pages 25 26 Water out Bypass in see pages 25 26 Insert Remove Insert Remove For filter head and scale filter installation use the guide supplied with the filter head an...

Page 17: ...v1 00 01 21 G5 BCS Quick Start Guide 17 SECTION 10 Fit the booster a b c d e f 10 15 Note Take care not to break the clips when removing or installing the booster Supplied with selected models or ava...

Page 18: ...tening hoses 3 8 BSP connections Booster Do not switch on electrical power until commissioning Do not over tighten hose connections Braided hoses supplied cannot be lengthened Cold water into booster...

Page 19: ...I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I 200mm 1 2kg cylinder 2 64kg cylinder Hook and loop strap and bracket Secure cylinder vertically to a robust surface with...

Page 20: ...dentification I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I Cylinder pressure Outlet pressure Braided hose connection 1 2kg cylinder non adjustabl...

Page 21: ...tion 13 Do not proceed if the seals are damaged Take care not to cross thread the regulator a cross threaded regulator poses a potential hazard I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I...

Page 22: ...tor is turned all the way OFF anti clockwise Turn the gas ON using the cylinder valve 2 64Kg cylinder anti clockwise Turn the regulator control knob clockwise to adjust the outlet pressure to 3 0 bar...

Page 23: ...and in no case should the normal operating pressure of 3 0 bar be exceeded Apply soapy water to the gas connections see below using a brush If there is a leak bubbles will appear In the case of a leak...

Page 24: ...ion instructions Mains power cable Installation diagrams are for illustrative purposes only Hoses are not shown to scale and cannot be lengthened Tips for hose connection Push the silicone hose over t...

Page 25: ...AINS IN hich way round arkling Mains Water BCS60 BCS100 models Zenith Vented Mixer Tap connections if supplied SECTION 13 Connect the Command Centre Fit foam insulation supplied to the BLUE and WHITE...

Page 26: ...OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT AMBIENT OUTLET USB BA res comm C res CHILLED OUTLET MAINS IN USB USB S NS Mains Water BCS20 BCS30 BCS Home models Zenith Vented Mixer Tap connections...

Page 27: ...2 12 PM TANK FLUSH Follow the prompts to flush fresh water through the tank s 3 times as shown by the cycle counter s The tank s will fill automatically but when prompted use the tap to dispense and e...

Page 28: ...5 BCS Quick Start Guide Zenith Heaters Limited IRD GST No 95 640 729 18 Kawakawa Place Westgate Auckland 0814 New Zealand Ph 64 9 838 8612 Free Call 0800 558 055 zenithwater co nz AU02691 WMKA00099 AS...

Reviews: