POST
COUNTDOWN
NUMBER
ERROR
MESSAGE
NUMBER
MESSAGE
SOLUTION
758
First 64K address line failure
Call your service representative
759
First 64K RAM parity test failure
Call your service representative
730
Initialize stack
710
Initialize keyboard buffer
706
Fatal on-board video BIOS conflict at
E0000H
705
On-board video BIOS conflict at E0000H
704
Fatal on-board video BIOS conflict at
C0000H
703
On-board video BIOS conflict at C0000H
702
No BIOS for off-board VGA/EGA video
card found
701
Shadow of on-board video BIOS failure
700
Chipset initialization 4
700
Shadow of system BIOS failure
Call your service representative
690
CMOS checksum test
690
CMOS power failure
Run Setup utility. If problem
persists, call your service
representative.
691
CMOS checksum failure
Run Setup utility. If problem
persists, call your service
representative.
692
Extended CMOS checksum failure
Run Setup utility. If problem
persists, call your service
representative.
693
Default configuration failure, unable to
write FLASH memory
680
Initialize EISA slots
670
Initialize serial ports
660
Initialize parallel ports
04/APRIL/93 – 595-5484-UU
123
123
5-18
Problem Solving