Jumper Setting
Jumpers
Jumper block A selects SCSI-ID numbers, parity option, media
eject options, test functions, and terminator power. The actual
settings by the jumpers are changed only after the power is
turned ON. If any settings are changed, turn the power OFF once
and ON again. A jumper setting of 1, is a jumper installed across
labeled pins.
CD-ROM Option Jumper Settings.
FUNCTION
JUMPER
SETTING
DESCRIPTION
Parity
IN
Must be IN
PRV/ALW
OUT
Must be OUT
Test
OUT
Must be OUT
Term
OUT
Must be OUT
SCSI ID
These 3 jumper pin pairs set the SCSI ID number. When setting
numbers, follow the application software instuctions.
CD-ROM Option Jumper Settings.
JUMPER ID NUMBERS
SCSI-ID
ID1
ID2
ID3
0
OUT
OUT
OUT
1
IN
OUT
OUT
2
OUT
IN
OUT
3
IN
IN
OUT
4
OUT
OUT
IN
*5
IN
OUT
IN
6
OUT
IN
IN
7
IN
IN
IN
* Setting for devices installed at the factory.
04/APRIL/93 – 595-5484-UU
184
184
D-16
Devices