SCSI
ADDRESS
SWITCH SETTINGS
S3
S2
S1
0
OFF
OFF
OFF
1
OFF
OFF
ON
2
OFF
ON
OFF
3
OFF
ON
ON
4
ON
OFF
OFF
5
ON
OFF
ON
6*
ON
ON
OFF
7
ON
ON
ON
* Default Setting
SCSI Termination
If the drive you are installing has terminator resistors installed,
you must remove them. Refer to the illustration at the end of this
section for the location of the terminator resistors. Termination is
supplied by the inline terminator plug on the end of the SCSI
signal cable (P7)
Bay Assignment
The DAT tape device should be installed in upper Bay C, located
above the control panel.
BAY
DEVICE
A
1.44M Floppy Disk Drive (Drive A)
(Always installed)
B
1.2M Floppy Disk Drive
1.44M Floppy Disk Drive (Drive B)
CD ROM (SCSI address 5)
C
525M Tape (SCSI address 2)
DAT (SCSI address 6)
CD ROM (SCSI address 5 - alternate location if floppy disk
drive is in Bay B)
04/APRIL/93 – 595-5484-UU
197
197
D-29
Devices