Page 16
TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
NOTE:
Standard Programming
The codes below should meet the needs of most users for normal pump operations. If other
functions are desired from ZeDrive, consult “Complete Code List”.
Code
Description
Value/Calculation
Meaning
01
Primary Setpoint 1
User Defined
Pump speed setpoint (in Pump RPM)
10
Minimum Limit
0
Minimum motor speed for operation
11
Maximum Limit
1800
Maximum motor speed for operation
12
Low Alarm
0
Motor speed level which Low Alarm output is energized
13
High Alarm
1800
Motor speed level which High Alarm output is energized
16
Acceleration Time
10
Seconds for motor to increase from 0 RPM to 1800 RPM
17
Deceleration Time
5
Seconds for motor to decrease from 1800 RPM to 0 RPM
20
Primary Setpoint Maximum
1800/
Gear Ratio
Unit of primary setpoint is in Pump RPM
22
Primary Display Maximum
1800/
Gear Ratio
Unit of primary display is in Pump RPM
31
PPR—Feedback Input
120
The resolution of the feedback sensor used in the system
34
Max. RPM Feedback - Primary
1800
Full-scale speed of motor
61
Primary Output Format
1
Master Mode
63
Primary Display Format
1
Master Mode
84
Analog Input Function Select
0
Analog input not used
Summary of Contents for ZeDrive
Page 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Page 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Page 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Page 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Page 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...