Page 48
TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
22
Primary Display Maximum
Default:
1800
Units:
eng
Range:
0~9999
23
Secondary Display Maximum
Default:
1800
Units:
eng
Range:
0~9999
29
Recovery Multiplier
Default:
0.0
Units:
Range:
0.0~100.0
30
External Reference PPR
Default:
120
Units:
PPR (Number of Pulses Per Revolution)
Range:
0~3270
31
Feedback Reference PPR
Default:
120
Units:
PPR (Number of Pulses Per Revolution)
Range:
0~3270
32
Auxiliary Input PPR
Default:
120
Units:
PPR (Number of Pulses Per Revolution)
Range:
0~3270
It determines the rate at which the pulse error is reduced
to zero. This parameter multiplied by the pulse error
count is the number by which the speed setpoint is
adjusted every 100 milliseconds.
It is the number of pulses generated by the device
attached to External Reference Input for each revolution
of its shaft.
It is the number of pulses per revolution generated by
the device attached to Motor Shaft.
It is the number of pulses generated by the device
attached to Auxiliary/Offset Frequency Input for each
revolution of its shaft.
This parameter is similar to C20, but will be used for
display, thus allowing a scale factor to be introduced
between the controlled process and the display. The
format of the number entered here (number of digits to
the right of decimal point) will be used for the speed
display. This parameter is used when one of the primary
setpoints is active.
This parameter is similar to C22, but will be used for
display, thus allowing a scale factor to be introduced
between the controlled process and the display. The
format of the number entered here (number of digits to
the right of decimal point) will be used for the speed
display. This parameter is used when one of the
secondary setpoints is active.
Summary of Contents for ZeDrive
Page 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Page 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Page 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Page 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Page 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...