Page 50
TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
M40
Tachometer
Read Only
Units:
eng
Range:
M41
External Reference Input
Read Only
Units:
Hz
Range:
M42
Auxiliary / Offset Frequency Input
Read Only
Units:
Hz
Range:
It displays the frequency of Auxiliary/Offset Frequency
Input in hertz (pulses per second). The number
displayed is not averaged. It represents the frequency
calculation from the prior 10 milliseconds before the
display update. Because it is not averaged over the
display update period, it appears less stable than
Tachometer display due to sensor irregularities or other
system dynamic errors.
It may contain numbers larger than 9999. When this
occurs, the value is displayed differently. For example, a
"10.00." display indicates 10,000 Hz.
It is the feedback displayed in scaled Engineering Units.
The feedback input is read by ZeDrive every 10
milliseconds. The readings are summed and averaged
for one second before displaying
It displays the frequency of External Reference Input in
hertz (pulses per second). The number displayed is not
averaged. It represents the frequency calculation from
the prior 10 milliseconds before the display update.
Because it is not averaged over the display update
period, it appears less stable than Tachometer display
due to sensor irregularities or other system dynamic
errors.
It may contain numbers larger than 9999. When this
occurs, the value is displayed differently. For example, a
"10.00." display indicates 10,000 Hz.
Summary of Contents for ZeDrive
Page 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Page 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Page 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Page 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Page 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...