background image

Page 59 

TO GET ASSISTANCE, CALL: 919-774-7667 

ZENITH PUMPS 

12.

00

12.

75

8.

00

10.

00

Equi

pme

nt Gr

ound

TB1

TB

2

OP

TI

ONA

L  

   

INT

R

INSICA

LL

Y

SA

FE

 BA

R

R

IE

R

Equ

ipment 

Gr

ound

Do

or

 

G

as

ket

PA

NE

L C

U

TO

U

7.

25" ± .

03"

X  

3.

65" ± .

03"

Ø0

.31

2.

00

2.

00

L1

L2

/N

eu

t

IN

PU

T P

O

W

E

R

115 /

 230 V

A

C

, 1

 P

H

A

SE,

 50/

60

 Hz

C

ha

ss

is

 Gr

ou

nd

M

oto

r Ar

m

atu

re

 Le

ad

s

Mo

to

r F

iel

d

 Le

ad

s

A2

A1

F1

F2

1

2

3

4

5

6

7

1

2

3

4

5

6

7

8

9

10

11

12

FEEDB

A

CK

SI

G

N

A

L

IN

TE

R

-

LO

CK

AN

AL

OG

IN

P

U

T

AN

AL

OG

O

U

TPUT

+12 VDC

SIG

N

A

L +

C

O

MMO

N

SHI

E

LD

RO

MOV

E

JUM

PER

IN

PUT

 +

CO

M

M

ON

OU

TP

U

T +

SH

IE

LD

J 2

J 1

J 3

J 4

NOTES: 

  1.

 

FOR INTERCONNECT WI

RING BETWE

EN ZeDRIVE 

AND

 TERMIN

AL 

STRI

PS, R

E

FER TO

 NE

XT

 P

A

GE. IN-

TERCO

NNECT 

WIRING 

TO BE IN

SUL

A

TED

 C

O

PP

ER 

COND

UCT

O

R, R

A

TE

AT

 600V

, 90 DE

GREES 

CENT

I-

GRADE. 

2. 

COMMON AND 

GROUN

D

 CONNE

CTI

O

NS ON THE

 

ZeDRIVE 

ARE OF DIFFE

RENT POTENTIAL. KEEP 

SEPA

RA

TE. 

3.

 

TERMINAL STRIP

ARE IE

C T

Y

PE. 

4.

 

NE

MA 12

 C

A

BI

NE

T, 

12

"H

 X 10

"W X 8

"D. 

NOTES: 

  MOTO

R ARM

A

TU

RE 

A

N

D FIELD 

LEA

D

MUST

 BE RU

N SEPER

A

TE 

FROM 

SHIELDED SI

GNAL CABLES TO 

AVOI

SIGNAL NOISE IN FEEDB

A

CK. 

Summary of Contents for ZeDrive

Page 1: ...derutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In s...

Page 2: ...CODE DESCRIPTION CODE DESCRIPTION CODE DESCRIPTION 1 PRI SETPT 1 16 ACCEL RATE 40 TACH 2 PRI SETPT 2 17 DECEL RATE 41 EXTERNAL REF 3 SEC SETPT 1 61 CTRL PRI 42 AUX INPUT 4 SEC SETPT 2 62 CTRL SEC 43 F...

Page 3: ...etpoint 26 Feedback Control by Using a Flowmeter with Frequency Signal 27 Feedback Control by Using a Flowmeter with 4 20 mA Signal 29 Feedback Control by Using a Flowmeter with 0 10 VDC Signal 30 Mas...

Page 4: ...ation cont d Replaced Feedback Sensor Fits the Existing ZeDrive Or Not 41 Display Shows 1 2 or 3 41 Restore Back to Factory Defaults 41 Can Not Operate from Keypad 42 The Display Would Not Light Up 42...

Page 5: ...ve can receive three frequency inputs supporting magnetic pickup zero crossing or open col lector type sensor It comes standard with a RS 485 as well as a RS 422 computer interface allowing to monitor...

Page 6: ...in Reset and Rate Scaling Format Master Follower Offset Direct Keypad Controls Set Speed Tach Display Numeric Keys Up Down Buttons Serial Communication RS 422 Full parameter access control Protection...

Page 7: ...14 15 16 17 Feedback Sensor Ext Ref Sensor Offset Sensor JOG R STOP RUN F STOP Spare Closed Open Loop Ramp Disable Primary Setpt 2 Primary Setpt 1 Keypad Lockout Primary Secondary Secondary Setpt 3 Se...

Page 8: ...rive from the panel front and slide it in until it is flush with the panel surface Ensure that supplied gasket is between the drive bezel and panel surface Re install the locking cam fasteners from th...

Page 9: ...onduit from low voltage 50 V or signal wiring If run parallel to each other high voltage wiring should be separated from low voltage and signal wiring by 12 inches or as much as physically possible If...

Page 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...

Page 11: ...74 7667 ZENITH PUMPS 1 Connect Input Power Customer supplies input AC power NOTE Make sure to set power selection switch to correct power voltage configura tion 115 230 VAC 10 15 1 Phase 50 60 Hz 3 Wi...

Page 12: ...ounter clockwise rotation at the reducer output shaft viewed from the pump end as opposed to the motor end This rotation should be correct for most applications If the rotation is in correct reverse A...

Page 13: ...end as opposed to the motor end This rotation should be correct for most applications If the rotation is in correct reverse A1 and A2 connections If the motor in use has a thermostat it may be connec...

Page 14: ...d Hall Effect Sensor Wire Color Function Connect To Red 12VDC TB2 1 White Clear Feedback Signal TB2 2 Black Common TB2 3 Bare Shielding TB2 4 Encoders Wire Color Function Connect To Red 12VDC TB2 1 Wh...

Page 15: ...al feedback signal in engineering unit Scroll Buttons To increase decrease the value showing in LED display CLEAR To erase value in LED display or code number under code select mode ENTER To enter new...

Page 16: ...Value Select Code View Its Value Tach Display Modify Value SET SPEED 6 0 Previous Display Current Set Speed CODE SELECT ENTER 1 Or Enter New Set Speed New Set Speed TACH Previous Display Actual Speed...

Page 17: ...Alarm output is energized 13 High Alarm 1800 Motor speed level which High Alarm output is energized 16 Acceleration Time 10 Seconds for motor to increase from 0 RPM to 1800 RPM 17 Deceleration Time 5...

Page 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...

Page 19: ...rive If the power is 230 VAC please refer to Trouble shooting section 4 Configure ZeDrive A 5 091 1 reducer and 120 teeth pickup gear is used for the following example Change values for codes 20 22 an...

Page 20: ...Please refer to Trouble shooting sec tion If the system runs at right speed stop the system and discon nect the power The system is ready for normal operation Zenith Pumps SET SPEED TACH 7 4 1 8 5 2...

Page 21: ...p based on Accel eration Time defined in Code 16 2 Stop Button Use a momentary button Connect the button to J3 connector Pin 11 and Pin 12 When opened ZeDrive will ramp down to zero speed based on Dec...

Page 22: ...rectly coupled with the motor the gear ratio R 1 Motor maximum speed VM RPM 2 Calculation None 3 Coding Check and change the following codes Code 10 0 Code 11 VM Code 20 VM R Code 22 VM R Code 34 VM C...

Page 23: ...with the motor the gear ratio R 1 Motor maximum speed VM RPM Pump Capacity CP cc rev 2 Calculation None 3 Coding Check and change the following codes Code 10 0 Code 11 VM Code 20 VM R CP Code 22 VM R...

Page 24: ...ent between other unit and cc min KU Find out 1 new volume unit is equal to V cc Find out 1 new time unit is equal to T min 1 volume time V cc T min V T cc min KU V T Example If the preferred unit is...

Page 25: ...n at the left 2 Calculation None 3 Coding Check and change the following codes Code 80 input corresponding code number for monitoring that specific variable Example Code 80 40 it will monitor TACH whi...

Page 26: ...eeth of Feedback Gear N 120 for most of systems supplied by Zenith 2 Calculation To set the motor speed to be V RPM 0 V VM the pump to be V RPM 0 R V VM R or the output to be V cc min 0 R CP V VM R CP...

Page 27: ...eeth of Feedback Gear N 120 for most of systems supplied by Zenith 2 Calculation To set the motor speed to be V RPM 0 V VM the pump to be V RPM 0 R V VM R or the output to be V cc min 0 R CP V VM R CP...

Page 28: ...For ZeDrive 2000 please proceed to the next step For a regular ZeDrive check and change the jumper settings on the Control Board 1 Loosen up 6 screws on the back panel and 2 screws located on the heat...

Page 29: ...gested speed limit Any restriction at the discharge side of the pump can rapidly increase the speed of pump This is the major causation making the pump over speed Check any down stream restrictions be...

Page 30: ...the wires from the flowmeter as shown at left Leave anything else unchanged as before 5 Result The output from the pump will be controlled by the flowmeter The units of the setpoint and the Tach are...

Page 31: ...e wires from the flowmeter as shown at left Leave anything else unchanged as before 5 Result The output from the pump will be controlled by the flowmeter The units of the setpoint and the Tach are sam...

Page 32: ...ck Sensor Resolution Ff No of Teeth 2 Calculation 2 1 Master Primary Setpoint Pm cc min Pm cc min VM RPM Rm Cm cc rev 2 2 Maximum Percent between Follower and Master Pf Pf Follower Max Flowrate cc min...

Page 33: ...are wire shield wire Connect wires like the following illustration to form a master follower system for detailed connection please refer to page G 4 in ZeDrive and ZeTrol Manual Follower ZeDrive 1 2 3...

Page 34: ...rimary Setpoint 1 Code 01 i e 20 cc min The master system should run and the follower system should run and deliver 75 the flowrate the master system delivers Stop the master system the follower will...

Page 35: ...2 Neutral 2 2 Turn the current limit potentiometer at the rear of ZeDrive fully clockwise 2 3 With ZeDrive in the RUN state gradually in crease the load until the AC ammeter reaches the desired limit...

Page 36: ...DC or 4 20 mA calibration signal to ZeDrive Locate Analog Select Jumpers on Control Board 1 Loosen up 6 screws on the back panel and 2 screws located on the heat sink of ZeDrive 2 Remove the back pane...

Page 37: ...e a multi meter Locate Analog Select Jumpers on Control Board 1 Loosen up 6 screws on the back panel and 2 screws located on the heat sink of ZeDrive 2 Remove the back panel place ZeDrive as shown at...

Page 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...

Page 39: ...If the voltage always stay at 0 VDC or any value below 1 VDC please check the sensor wiring If the wiring is correct it may be a defected sensor Please contact Zenith for a re placed one If the voltag...

Page 40: ...of sensor you have please check the feedback jumper settings as shown at the left 3 System Always Runs at Full Speed Refer to 2 No Feedback Signal 4 System Can Not Run Below 30 RPM or 40 RPM Refer to...

Page 41: ...eck Code 16 for acceleration time Smaller the value lesser the time for the motor to ramp up However it may increase the chance to damage the pump due to the quick pressure build up caused by the rest...

Page 42: ...k panel and 2 screws located on the heat sink of ZeDrive 2 Remove the back panel Face the back of Ze Drive and place ZeDrive so that the heat sink points down 3 When you place ZeDrive as shown in step...

Page 43: ...fault values The defaults may NOT match the actual system you have 18 Can Not Operate from Keypad ZeDrive could be set for Analog Remote Control mode To use keypad on ZeDrive to control the system set...

Page 44: ...LIMIT alarm LED lights up This parameter establishes the point at which the LO ALARM output is turned on 13 LIMIT alarm LED lights up This parameter establishes the point at which the HI ALARM output...

Page 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...

Page 46: ...mat Multiplier ratio Offset output format Multiplier ratio This parameter establishes the speed at which the motor rotates during a JOG operation It is always measured at the drive motor shaft This pa...

Page 47: ...C15 the alarm is turned on This parameter establishes the maximum level of motor RPM during operation It is allowable to program a setpoint which is above this value however the controller will enfor...

Page 48: ...ized feedback pulses minus the Feedback pulses It may not always be desirable to recover all the position error lag Set this paramter to the desired lag pulse limit It sets a maximum pulse error count...

Page 49: ...hed to External Reference Input for each revolution of its shaft It is the number of pulses per revolution generated by the device attached to Motor Shaft It is the number of pulses generated by the d...

Page 50: ...Reference and is used in Follower or Offset formats when the primary data set is selected It sets the full scale speed of the motor When the motor is turning at this speed with a primary setpoint sel...

Page 51: ...larger than 9999 When this occurs the value is displayed differently For example a 10 00 display indicates 10 000 Hz It is the feedback displayed in scaled Engineering Units The feedback input is rea...

Page 52: ...le than Tachometer display due to sensor irregularities or other system dynamic errors It may contain numbers larger than 9999 When this occurs the value is displayed differently For example a 10 00 d...

Page 53: ...the forward reverse flag on ZeTrol Bit 5 Closed Loop 1 Open Loop 0 Bit 4 Primary Setpoint 1 1 Primary Setpoint 2 0 Bit 3 Secondary Setpoint 3 1 Secondary Setpoint 4 0 Bit 2 Local 1 Remote Serial 0 Con...

Page 54: ...Primary Scaling Format Default 1 62 Secondary Scaling Format Default 1 Units Range 0 Direct 1 Master 2 Follower 3 Offset It is Analog Input 1 signal unadjusted for Zero and Span It is Analog Input 1 s...

Page 55: ...smaller numbers mean more Gain This parameter sets Reset in PID control loop This is the integral part I of the equation It is an integer number between 0 and 9999 with 0 being the special case of no...

Page 56: ...y Setpoint Select 1 Bit 3 Secondary Setpoint Select 1 Bit 2 Run 1 Stop 0 Bit 1 Bit 0 Ramp Enable 1 Disable 0 This parameter sets a threshold below which the Rate term derivative term has no affect on...

Page 57: ...he Analog Output pins These are positive and negative offset numbers for primary and secondary data sets These allow the feedback to contain a bias Only one positive or negative number can be non zero...

Page 58: ...ace Setpoint 2 6 Replace Setpoint 3 7 Replace Setpoint 4 85 Analog Input ZERO Default 0 Units Range 0 2048 86 Analog Input SPAN Default 3900 Units Range 2048 4096 It allows user to zero adjust the ana...

Page 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...

Page 60: ...SIGNAL INTER LOCK ANALOG INPUT ANALOG OUTPUT 12 VDC SIGNAL COMMON SHIELD ROMOVE JUMPER INPUT COMMON OUTPUT SHIELD J 2 J 1 J 3 J 4 NOTES 1 FOR INTERCONNECT WIRING BETWEEN ZeDRIVE AND TERMINAL STRIPS R...

Page 61: ...Y THE OPPOSITE END OF THE SHIELD IS NOT CONNECTED 2 ROUTE SHIELDED CABLE SEPARATELY FROM POWER WIRING DO NOT ROUTE 115VAC CONTROL WIRING AND LOW LEVEL SIGNAL WIRING IN THE SAME CONDUIT DO NOT ROUTE FE...

Page 62: ...TB1 4 TO TB1 4 MOTOR END W COVER REMOVED TO TB1 5 CASE GROUND TO TB1 3 TO TB1 4 FIELD WOUND MOTORS TO TB1 5 1 2 HP EXPLOSION PROOF MOTORS TO TB1 4 TO TB1 5 NOTES 1 THE MOTOR CONNECTIONS SHOWN WILL PR...

Page 63: ...Phone 800 277 8968 Fax 919 774 5952 E mail zenithpumps zenithpumps com Zenith Pumps 5910 Elwin Buchanan Drive Sanford NC 27330 ZENITH PUMPS Zenith Pumps...

Page 64: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: