25
Code
Possible causes
Action
1
Short circuit return sensor
Check sensors, replace if needed
2
Interruption return sensor
Check sensors, replace if needed
3
Short circuit supply sensor
Check sensors, replace if needed
4
Interruption supply sensor
Check sensors, replace if needed
5
Hardware error
Exchange device
6
Battery empty or wrong temp.
sensor
Check device / sensor
7
Temperature out of measuring
range
Correction heating system,
check sensor type
100
Emergency operation
Exchange device
1000
Battery life time exceed
Exchange device
2000
Initial verification expired
Exchange device
> 8000 Internal hardware error
Exchange device
Error codes show faults detected by multidata WR3. If more than one error
appears, the sum of the error codes is displayed: Error 1005 = error 1000
and error 5.
Status display / Error codes
The symbols in the table below show the meter’s operational status. The
status messages only appear in the main display (energy). The tempo-
rary display of the warning triangle can be caused by special operating
states and does not always mean that the device is malfunctioning.
However, should the symbol be displayed over a longer period of time,
you should contact the service company! The corresponding error codes
can be found in the third menu level.
Symbol
Status
Action
External voltage
-
Flow existent
-
Attention!
Check system /device for errors
■
Symbol flashing:
Data transmission
■
Symbol constantly displayer:
optical interface active
-
-
Emergency operation
Exchange device