background image

   

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

BIN 44 / 4X / 2X 

 

 

 

 

 

Universal Interface with Binary Inputs  

and/or LED Lighting & Electronic Relay Outputs 

 

 

 
 
 
 

 

 

 

 

 

 

ZIO-BIN44 
ZIO-BIN4X 
ZIO-BIN2X 

 

U

S

E

R

 M

A

N

U

A

L

 

 

 

 

 

 

 

 

Application program version: [1.1], [1.2]  

User manual edition: [1.2]_a 

 

 

 

www.zennio.com

  

 

 

Summary of Contents for BIN 2x

Page 1: ...4X 2X Universal Interface with Binary Inputs and or LED Lighting Electronic Relay Outputs ZIO BIN44 ZIO BIN4X ZIO BIN2X USER MANUAL Application program version 1 1 1 2 User manual edition 1 2 _a www zennio com ...

Page 2: ...3 1 Introduction 4 1 1 BIN 4 1 1 1 BIN 44 4 1 1 2 BIN 4X 4 1 1 3 BIN 2X 5 1 2 Installation 6 2 Configuration 8 2 1 General 8 2 2 Inputs Outputs 10 2 2 1 BIN 44 10 2 2 2 BIN 4X 2X 10 2 2 3 Binary Input 10 2 2 4 LED Lighting Output 10 2 2 5 Electronic Relay Control Heating Actuator 14 ANNEX I Communication Objects 15 ...

Page 3: ...nnio com Technical Support http support zennio com 3 DOCUMENT UPDATES Version Changes Page s 1 1 _a Application program changes Optimisation of the binary inputs electronic relay control and heartbeat module Minor text changes ...

Page 4: ... and switches or to operate low current relays e g heating system relays The BIN product family also incorporates the Heartbeat function which consists in sending a periodical still alive notification to the KNX bus The number of input and output channels depends on each specific model being fixed in some of them or configurable by the integrator in those models where a sole channel can work eithe...

Page 5: ...4 4X 2X http www zennio com Technical Support http support zennio com 5 1 1 3 BIN 2X 2 input output channels freely configurable as Binary inputs LED Lighting Output Electronic Relay Control Heating Actuator ...

Page 6: ...since it is entirely powered through the KNX bus Figure 1 Element diagram The main elements are described next Prog Test Button 2 a short press on this button sets the device into the programming mode making the associated LED 3 light in red If this button is held at the same time of applying bus power to the device BIN will enter the Safe Mode In such case the LED will intermit in red Slots for t...

Page 7: ...zennio com 7 To obtain further information about the technical features of BIN 44 4X 2X and on security and installation procedures please refer to the Datasheet of the device bundled with the original packaging and also available at the http www zennio com website ...

Page 8: ...eneral From this screen it is possible to activate deactivate all the required functionality Figure 3 Default configuration BIN 44 Start up Delay 0 255 1 sets a delay after the initialisation so the device does not respond to orders nor send objects to the bus except the Heartbeat object if enabled see below Input Output x Disabled Binary Input LED Lighting Output Electronic Relay Control Heating ...

Page 9: ...explained in later sections of this document Figure 4 Default configuration BIN 4X Heartbeat Periodic Alive Notification enabled disabled lets the integrator incorporate a one bit object to the project Heartbeat Object to Send 1 that will be sent periodically with value 1 to notify that the device is still working still alive Figure 5 Heartbeat Periodic Alive Notification Note the first sending af...

Page 10: ...nels each of them configurable as a Binary Input See section 2 2 3 LED Lighting Output See section 2 2 4 Electronic Relay Control Heating Actuator See section 2 2 5 2 2 3 BINARY INPUT Please refer to the Binary Inputs user manual available in the BIN product section at the Zennio website http www zennio com 2 2 4 LED LIGHTING OUTPUT The LED lighting control permits commuting each LED between two s...

Page 11: ... the normal mode and for the night mode if required ETS PARAMETERISATION A general Configuration tab for the LED Outputs function is provided once at least one output has been configured as a LED Lighting Output This tab contains the settings that are common to all LED outputs Figure 6 LED Outputs General configuration Normal Mode enabled On Level 0 255 sets the brightness level value for on state...

Page 12: ...ive after an ETS Download 1 bit Object enabled disabled when marked it will be possible to switch the mode by writing to a binary object LED Brightness Mode The parameter Value 0 Normal 1 Night 0 Night 1 Normal will show up to select which value should trigger which mode Scene Object enabled disabled when marked it will be possible to switch the mode by writing a certain scene value to LED Scene T...

Page 13: ...cific trigger object is received ETS PARAMETERISATION A specific Configuration tab is provided for each enabled LED output It contains the following parameters Figure 8 Ouput X LED Lighting Configuration Show Status Objects enabled disabled if enabled the LEDx LED Status object is added to the project It takes value 0 when the LED is in the off state and value 1 when the LED is in the on state Thi...

Page 14: ...e 0 the LED will switch to the on state while the value 1 will switch it off LEDx Timer binary when it receives the value 1 the LED timer function will start while the value 0 will stop it LEDx Flashing binary when it receives the value 1 the LED flashing function will trigger while the value 0 will stop it 2 2 5 ELECTRONIC RELAY CONTROL HEATING ACTUATOR Please refer to Electronic Relay Control in...

Page 15: ... 1 Bit C T DPT_UpDown 0 1 Ix Short Press Move Up Shutter Sending of 0 Up 1 Bit C T DPT_UpDown 0 1 Ix Short Press Move Down Shutter Sending of 1 Down 1 Bit C T DPT_UpDown 0 1 Ix Short Press Move Up Down Shutter Switching 0 1 Up Down 1 Bit C T DPT_Step 0 1 Ix Short Press Stop Step Up Shutter Sending of 0 Stop Step Up 1 Bit C T DPT_Step 0 1 Ix Short Press Stop Step Down Shutter Sending of 1 Stop Step...

Page 16: ...Pulse Counter Counter Number of Pulses 3 9 15 21 1 Byte I C W DPT_Scaling 0 100 Ix Short Press Shutter Status Input 0 Top 100 Bottom 1 Byte I C W DPT_Scaling 0 100 Ix Short Press Dimming Status Input 0 100 1 Byte O C T R DPT_Value_1_Ucount 0 255 Ix Pulse Counter Counter Number of Pulses 4 10 16 22 1 Bit C T DPT_Switch 0 1 Ix Long Press 0 Sending of 0 1 Bit C T DPT_Switch 0 1 Ix Long Press 1 Sendin...

Page 17: ...es C T 9 xxx 671088 64 670760 96 Ix Long Press Constant Value Float Float Value 2 Bytes C T DPT_Value_2_Ucount 0 65535 Ix Long Press Constant Value Integer 0 65535 1 Byte C T DPT_Scaling 0 100 Ix Long Press Constant Value Percentage 0 100 1 Byte C T DPT_Value_1_Ucount 0 255 Ix Long Press Constant Value Integer 0 255 1 Bit C T DPT_Switch 0 1 Ix Double Press 0 Sending of 0 1 Bit C T DPT_Switch 0 1 I...

Page 18: ... 26 1 Byte O C T R DPT_Scaling 0 100 HC Max Control Value Output 0 100 49 27 1 Byte I C W DPT_Scaling 0 100 HC Max Control Value Input 0 100 52 64 76 88 30 42 1 Bit I C W DPT_Enable 0 1 HCx Lock 0 Unlock 1 Lock 53 65 77 89 31 43 1 Bit I C W DPT_Alarm 0 1 HCx Alarm 0 No Alarm 1 Alarm 1 Bit I C W DPT_Alarm 0 1 HCx Alarm 0 Alarm 1 No Alarm 54 66 78 90 32 44 1 Bit I C W DPT_Alarm 0 1 HCx Alarm 2 0 No ...

Page 19: ...rol Value 1 bit Status 0 Off 1 On 60 72 84 96 38 50 1 Byte I C W DPT_Scaling 0 100 HCx Control Value 1 byte 0 100 61 73 85 97 39 51 1 Byte O C T R DPT_Scaling 0 100 HCx Control Value 1 byte Status 0 100 98 52 1 Bit C T DPT_Trigger 0 1 Heartbeat Object to Send 1 Sending of 1 Periodically Does not apply to BIN 2X Only applies to BIN 2X ...

Page 20: ...in and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnología S L C Río Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio com ...

Reviews: