KLIC-DD v3

 

http://www.zennio.com

 

              

Technical Support:

 

http://support.zennio.com

 

 

DOCUMENT UPDATES 

 

 

Version 

Changes 

Page(s) 

[1.1]_a 

Changes in the application program: 

AC unit operation time counter. 

Temperature measured by the A/C Unit. 

Advanced climate control through external reference 

temperature. 

LED notification of internal errors. 

Optimisation of the Heartbeat, binary inputs, 

temperature probe and motion detector module. 

AC unit operation time counter.

 

10, 21-22 

Temperature measured by the A/C Unit.

 

9, 14 

Advanced climate control through external reference 

temperature.

 

9, 16-17 

LED notification of internal errors.

 

26 

Summary of Contents for KLIC-DD v3

Page 1: ...KLIC DD v3 KNX Daikin Gateway for Domestic Range Daikin A C Units USER MANUAL ZCLDDV3 Application program version 1 1 User manual edition 1 1 _a www zennio com...

Page 2: ...D v3 4 1 2 Installation 5 1 3 Start Up and Power Loss 6 2 Configuration 7 2 1 General 7 2 2 AC Gateway 9 2 2 1 Configuration 9 2 2 2 Initial Configuration 22 2 2 3 Scenes 24 2 2 4 Error Handling 26 2...

Page 3: ...sured by the A C Unit Advanced climate control through external reference temperature LED notification of internal errors Optimisation of the Heartbeat binary inputs temperature probe and motion detec...

Page 4: ...controls Moreover the actual status of the unit can be monitored and periodically sent to the KNX bus to inform other devices The most outstanding features of KLIC DD v3 are Bidirectional control of d...

Page 5: ...ill set the device into the programming mode making the associated LED 1 light in red Note if this button is held while plugging the device into the KNX bus the device will enter into safe mode The LE...

Page 6: ...ailed information about the technical features of KLIC DD v3 as well as on security and installation procedures please refer to the device Datasheet bundled in the device packaging and also available...

Page 7: ...nit and management of the climate control system For more information see section 2 2 Inputs disabled enabled enables or disables the Inputs tab in the tree on the left For more information see sectio...

Page 8: ...respectively AC Temperature Setpoint and AC Temperature Setpoint Status allow setting the desired temperature setpoint or reading the current value respectively See section 2 2 1 for further informat...

Page 9: ...izontal flaps or both types depending on A C unit Moreover KLIC DD v3 allows configuring several advanced functions Temperature measured by the AC unit allows enabling an object which provides the val...

Page 10: ...des the A C unit operating time in hours and or seconds These functionalities imply changes in the state of the A C unit which therefore notifies KLIC DD v3 periodically about the current state When K...

Page 11: ...itional modes will be available See paragraph Humidity in this section Additionally a simplified mode can be configured to select Cooling and Heating mode Simplified Mode disabled enabled in addition...

Page 12: ...or commuting or consulting the operating state In both cases the following parameter Swing Object Polarity 0 Swing On 1 Swing Off 0 Swing Off 1 Swing On defines which value activates each swing Figure...

Page 13: ...rent status respectively Moreover the polarity can be configured by parameter Automatic Mode Object Polarity 0 Automatic On 1 Automatic Off 0 Automatic Off 1 Automatic On sets the polarity of the abov...

Page 14: ...entail one more parameter Period 1 3600 s 1 15 1440 min 1 24 h sets the cycle time for the periodic sending Figure 8 AC Gateway Configuration Temperature measured by the AC unit TEMPERATURE SETPOINT...

Page 15: ...ry Mode 10 32 C sets the upper limit Maximum Heating Auto Mode 10 32 C sets the lower limit Figure 9 AC Gateway Configuration Temperature setpoint Once these limits are enabled several objects to modi...

Page 16: ...e indicated in Table 3 Mode Temperature Setpoint Auto 18 30 Cooling 18 32 Heating 10 30 Fan Not available Dry Not available Table 3 Interior setpoint limits of A C unit REFERENCE TEMPERATURE To contro...

Page 17: ...ge the setpoint from it HUMIDITY The availability of humidity control depends on A C unit model and can be activated by the parameter Humidifying Unit disabled enabled enables humidity control functio...

Page 18: ...tivation is received while the unit is on it will be ignored To activate the Ururu humidification operation or to supervise its status the following objects are available AC Ururu 1 bit object to acti...

Page 19: ...ctivate or deactivate Sarara Drying operation AC Sarara Status 1 Bit object that provides Sarara Drying operation status Once Sarara drying operation is activated Dry mode and a low humidity operation...

Page 20: ...trigger Automatic off will be also active if the unit is previously in off state so the unit will not be able of being on until this situation finishes During the temporary switch off state KLIC DD v...

Page 21: ...sisting each of them in a set of orders to be sent to the A C unit upon the reception of scene trigger values through the KNX bus See section 2 2 3 OPERATING TIME Figure 12 AC Gateway Configuration Op...

Page 22: ...til the user reset it 2 2 2 INITIAL CONFIGURATION The custom initial configuration allows setting the desired status that KLIC DD v3 will send the A C unit after downloading or restarting the device T...

Page 23: ...ction 2 2 1 and a Mode allowing humidity control has been selected in the parameter above Heating Cooling or Dry mode Otherwise this parameter will be disabled indicating Not Available or Not Availabl...

Page 24: ...to the tab tree It allows setting up different scenes up to 5 consisting each of them in a set of orders to be sent to the A C unit upon the reception through the KNX bus and by means of the AC Scenes...

Page 25: ...Notes This parameter is only available if the humidifying unit is enabled in the A C gateway configuration see section 2 2 1 and a Mode allowing humidity control has been selected in the parameter ab...

Page 26: ...nce the error is over the object will be sent with value 0 The object associated with each error will be respectively AC Internal Error Communication 1 Bit AC Internal Error Wrong Acknowledgement 1 Bi...

Page 27: ...com 2 3 2 TEMPERATURE PROBE Please refer to the Temperature Probe user manual available in the KLIC DD v3 product section at the Zennio website www zennio com 2 3 3 MOTION DETECTOR It is possible to c...

Page 28: ...28 Motion detectors with references ZN1IO DETEC and ZN1IO DETEC N are not compatible with KLIC DD v3 may report inaccurate measurements if connected to this device When connected to KLIC DD v3 the re...

Page 29: ...ecution of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after exe...

Page 30: ...3 00 670760 00 AC Temperature Setpoint Status 10 32 C 6 2 Bytes I C W DPT_Value_Temp 273 00 670760 00 AC Temperature Setpoint Lower Limit 18 32 C 7 2 Bytes O C T R DPT_Value_Temp 273 00 670760 00 AC T...

Page 31: ...DPT_Switch 0 1 AC Horizontal Flaps Swing Status 0 Swing Off 1 Swing On 1 Bit O C T R DPT_Switch 0 1 AC Horizontal Flaps Swing Status 0 Swing On 1 Swing Off 26 1 Bit I C W DPT_Switch 0 1 AC Vertical F...

Page 32: ...Press 0 Sending of 0 1 Bit C T DPT_Switch 0 1 Ix Short Press 1 Sending of 1 1 Bit I C T W DPT_Switch 0 1 Ix Short Press 0 1 Switching Switching 0 1 1 Bit C T DPT_UpDown 0 1 Ix Short Press Move Up Shut...

Page 33: ...Ix Short Press Constant Value Float Float Value 49 55 1 Byte I C W DPT_Scaling 0 100 Ix Short Press Shutter Status Input 0 Top 100 Bottom 1 Byte I C W DPT_Scaling 0 100 Ix Short Press Dimming Status...

Page 34: ...0 No Alarm 2 Bytes C T 9 xxx 671088 64 670760 96 Ix Long Press Constant Value Float Float Value 2 Bytes C T DPT_Value_2_Ucount 0 65535 Ix Long Press Constant Value Integer 0 65535 1 Byte C T DPT_Scali...

Page 35: ...ers 73 102 1 Bit O C T R DPT_Occupancy 0 1 Ix Presence Occupancy State 0 Not Occupied 1 Occupied 74 103 1 Bit I C W DPT_Ack 0 1 Ix External Motion Detection 0 Nothing 1 Motion detected by an external...

Page 36: ...F Function x Result 1 Bit Boolean 1 Byte O C T R DPT_Value_1_Ucount 0 255 LF Function x Result 1 Byte Unsigned 2 Bytes O C T R DPT_Value_2_Ucount 0 65535 LF Function x Result 2 Byte Unsigned 4 Bytes O...

Page 37: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...