background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KLIC-DD 

 

 

 

 

 

KNX 

 Residential A/C Unit Interface 

 

 

 

 

 

 

 

 

ZN1CL-KLIC-DD 

U

S

E

R

 M

A

N

U

A

L

 

 

 

 

 

 

 

 

Application program version: [1.5]  

User manual edition: [1.5]_c 

 

 

 

www.zennio.com

 

 

 

 

Summary of Contents for KLIC-DD

Page 1: ...KLIC DD KNX Residential A C Unit Interface ZN1CL KLIC DD USER MANUAL Application program version 1 5 User manual edition 1 5 _c www zennio com...

Page 2: ...nalities 7 3 ETS Parameterizacion 10 3 1 Default configuration 10 3 2 General window 12 3 2 1 Device model 12 3 2 2 Scenes 12 3 2 3 Temperature limitation 14 3 2 4 Auto OFF 15 3 2 5 Errors Management...

Page 3: ...zennio com Technical Support http support zennio com 3 DOCUMENT UPDATES Version Changes Page s 1 5 _c Minor text corrections 1 5 _b Enlarging the explanation of the Advanced Climate Management Minor...

Page 4: ...status of the air conditioning unit is checked and sent to the KNX bus for its monitoring KLIC DD combines the following features in the same device Bidirectional communication with A C units through...

Page 5: ...It is described below the functionality of its main elements Programming button 3 a short press on this button set the device in programming mode and the associated LED 2 lights red If this button is...

Page 6: ...unit Communication cable 5 wire cable to connect KLIC DD to the PCB board S21 of the inner unit of the A C unit To obtain more detailed information about the technical features of KLIC DD as well as...

Page 7: ...he available levels in the A C unit Swing swing or stopped These functionalities have associated a machine status which is periodically sent to KLIC DD When KLIC DD receives a status different from th...

Page 8: ...g the unit although it is in the auto off An example of this functionality could be the use of a window sensor associated to the auto switch off which allows switching off the machine if the window is...

Page 9: ...anel InZennio Z38i The advanced climate management is useful when the temperature measured by the external sensor is different than the measured by the A C unit The reference for the user is the tempe...

Page 10: ...device In the following sections there is a detailed explanation about each of the different functionalities of KLIC DD in ETS 3 1 DEFAULT CONFIGURATION This section shows the default configuration fr...

Page 11: ...ult As it can be seen in Figure 4 the configuration screen has 3 main windows General to individually enable each of the advanced functionalities of the A C machine Mode to configure features related...

Page 12: ...odel to control choosing between Conventional model or Humidify Dehumidify Indoor Unit The conventional model includes all the A C residential machines compatible with the KLIC DD interface If the sec...

Page 13: ...ossibility to choose the A C machine status No change OFF or ON Temperature No change or sending of a new temperature value from 18 C to 30 C Mode No change auto heat dry fan cool or humidify only for...

Page 14: ...be necessary to explicitly enable the temperature limitation by sending the value 1 through the specific communication object Temperature Limitation To control the machine using its predefined temper...

Page 15: ...nabled when enabling this parameter Yes it will be possible to restore the unit control although it is in auto off mode Auto OFF 1 If this option is disabled the unit cannot be controlled after an aut...

Page 16: ...ne indicates if an external error has occurred value 1 there is an error value 0 there is not The second object indicates the code that identifies the error see the specific manual of the A C unit ins...

Page 17: ...C DD delays the sending of the statuses to the KNX bus Send initial configuration to SPLIT If this sending is enabled Yes a new field will appear next Delay where to configure the time in seconds KLIC...

Page 18: ...f values is 3 48 When enabling this option two communication objects appear 2 bytes each Ambient Temperature and Modified Temperature The first one receives the value of the current temperature of the...

Page 19: ...upper than room temperature if the current room temperature stays constant to 22 C during the analyze period and setpoint is equal to 25 C the Modified Temperature that will be sent to the A C machine...

Page 20: ...erent and independent functions each of them entirely customisable and consisting in up to 4 consecutive operations each one The execution of each function can depend on a configurable condition which...

Page 21: ...ing The objects associated to the reception are Auto Mode Reception Cool Mode Reception Fan Mode Reception Heat Mode Reception and Dry Mode Reception Moreover the objects Mode Sending and Mode Recepti...

Page 22: ...eception for controlling and indicating the fan speed when requested The control object Fan Sending records the fan speed in percentage This value will be interpolated in such a way that corresponds t...

Page 23: ...the 1 bit object Fan 1 bit Sending that allows increasing sending the value 1 or decreasing value 0 the fan speed in one level for example for 3 levels in the minimum level of fan speed the value 1 i...

Page 24: ...byte Sending 0 Au 1 20 Mi 21 40 Mi Mid 5 levels 1 Byte I C T W U DPT_Scaling 0 100 Fan 1byte Sending 0 Aut 1 20 Min 21 60 Mid 60Ma 3 levels 4 1 Bit I C W U DPT_Switch 0 1 Swing Sending 0 Stop Step 1 S...

Page 25: ...Mode 0 Ignore 30 1 Bit O C T R DPT_Bool 0 1 Humidify Mode Reception 0 Disabled 1 Enabled 31 1 Byte O C T R DPT_Scaling 0 100 Humidify Level Reception 0 Off 25 Low 50 Med 75 Hi 32 1 Bit I C W U DPT_Sw...

Page 26: ...FF LF 2 bytes Data Entry 5 2 bytes Data Entry 66 2 Bytes I C W DPT_Value_2_Count 0 FFFF LF 2 bytes Data Entry 6 2 bytes Data Entry 67 2 Bytes I C W DPT_Value_2_Count 0 FFFF LF 2 bytes Data Entry 7 2 b...

Page 27: ...233 69 9 9 34 C2 59 EH 84 F4 109 JJ 134 P6 159 UF 184 38 209 51 234 6A 10 0A 35 C3 60 EC 85 F5 110 JE 135 P7 160 M0 185 39 210 52 235 6H 11 0H 36 C4 61 EJ 86 F6 111 JF 136 P8 161 M1 186 3A 211 53 236...

Page 28: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...