background image

 

 

 

KLIC-PA

 

http://www.zennio.com

 

              

Technical Support:

 

http://support.zennio.com

 

 

11 

2.4

 

AC GATEWAY 

2.4.1

 

CONFIGURATION 

KLIC-PA  allows  controlling  and  monitoring  an  air-conditioning  unit  in  the  same  way  it 

would be through the wired remote control it is provided with. 

Through  the  KNX  bus,  KLIC-PA  can  be  sent  orders  to  control  the  following  basic 

functions of the air conditioning unit: 

 

On/Off

 switch of the air-conditioning unit. 

 

Operation mode

: automatic, heating, cooling, fan and dry. 

 

Temperature  setpoint

,  which

 

can  be  modified

 

within  a  specific  range  of 

values, depending on the capabilities of the specific A/C unit being controlled. 

 

Fan speed

: three fan speeds. 

 

Control of flaps (or vanes) positioning

: direct positioning, swing movement 

and standby function, depending on the A/C unit. 

Moreover, KLIC-PA allows configuring several advanced functions: 

 

Setpoint limits

:

 

to restrict the range for the temperature setpoint. 

 

External reference temperature

: which allows enabling an object to use an 

external reference temperature, provided by a temperature probe. 

 

Filter

: which allows to know the filter status of the A/C Unit. 

 

Operating time

: provides the A/C unit operating time. 

 

Automatic off

, which allows an automatic and temporary switch-off of the unit 

(after  a  pre-established  delay,  if  desired)  when  the  communication  object 

associated to this function is triggered due to a certain event.  

 

Initial configuration

: which allows establishing the desired initial parameters 

for the state of the A/C unit after programming or restarting the device. 

Summary of Contents for KLIC-PA

Page 1: ...KLIC PA KNX Panasonic Gateway for Panasonic A C Units USER MANUAL ZCLPA Application program version 1 0 User manual edition 1 0 _a www zennio com...

Page 2: ...nstallation 4 1 3 Start Up and Power Loss 5 2 Configuration 6 2 1 General 6 2 2 Inputs 8 2 2 1 Binary Input 8 2 2 2 Temperature Probe 8 2 2 3 Motion Detector 9 2 3 Logic Functions 10 2 4 AC Gateway 11...

Page 3: ...t can be monitored and periodically sent to the KNX bus to inform other devices The most outstanding features of KLIC PA are Bidirectional control of Panasonic A C units through the connection wires R...

Page 4: ...device into the programming mode making the associated LED 1 light in red Note if this button is held while plugging the device into the KNX bus the device will enter into safe mode The LED will blink...

Page 5: ...of KLIC PA as well as on security and installation procedures please refer to the device Datasheet bundled in the device packaging and also available at http www zennio com 1 3 START UP AND POWER LOSS...

Page 6: ...ATION Figure 3 General The General screen is shown in the first place containing the following parameters Heartbeat Periodic Alive Notification disabled enabled 1 this parameter lets the integrator in...

Page 7: ...Off and AC On Off Status allow switching on value 1 and off value 0 the A C unit or reading the current status respectively AC Temperature Setpoint and AC Temperature Setpoint Status allow setting the...

Page 8: ...ll not work properly with KLIC PA ETS PARAMETERISATION When Inputs has been activated in the General parameters screen the following drop down lists will be available for the selection of the specific...

Page 9: ...ZN1IO DETEC P motion detector is compatible with a variety of Zennio devices However depending on the device it is actually being connected to the functionality may differ slightly Therefore please re...

Page 10: ...ution of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after execu...

Page 11: ...f flaps or vanes positioning direct positioning swing movement and standby function depending on the A C unit Moreover KLIC PA allows configuring several advanced functions Setpoint limits to restrict...

Page 12: ...the state of the A C unit which therefore notifies KLIC PA periodically about the current state When KLIC PA is notified about a change it updates the status objects and sends them to the KNX bus In a...

Page 13: ...KLIC PA http www zennio com Technical Support http support zennio com 13 Figure 6 A C Gateway Configuration OPERATION MODES Figure 7 A C Gateway Configuration Operation modes...

Page 14: ...ling and Heating mode Simplified Mode disabled enabled in addition to the AC Mode and AC Mode Status 1 Byte objects available by default it is possible to commute and to verify the current operation m...

Page 15: ...ps or vanes that direct the air flow outwards To that end KLIC PA provides a percentage control Flaps disabled enabled allows the percentage control type which will be applied in flaps Flaps position...

Page 16: ...e respectively Swing Object Polarity 0 Swing On 1 Swing Off 0 Swing Off 1 Swing On sets the polarity of the above objects Besides KLIC PA allows activating the Standby function in case of being availa...

Page 17: ...following table show the percentage values that correspond to the three levels Control Values Status Value Level Sent to the Unit 1 33 33 1 minimum 34 66 66 2 67 100 100 3 maximum Table 4 Fan speed Th...

Page 18: ...oint from below in the Cooling Dry and Auto modes and from above in the Heating and Auto modes provided that the limits are still within the predefined limits of the A C unit When KLIC PA receives an...

Page 19: ...C Unit use as reference to do the temperature control In addition is possible to configure the next option External Reference Temperature Object disabled enabled enables a 2 Byte object AC External Re...

Page 20: ...perating time The operating time of the A A machine in hours and or seconds can be known The available parameters in ETS are Seconds disabled enabled enables the 2 Byte object AC Operating time s This...

Page 21: ...event trigger Automatic off will be also active if the unit is previously in off state so the unit will not be able of being on until this situation finishes During the temporary switch off state KLI...

Page 22: ...each of them in a set of orders to be sent to the A C unit upon the reception of scene trigger values through the KNX bus See section 2 4 3 2 4 2 INITIAL CONFIGURATION The custom initial configuratio...

Page 23: ...ng 1 2 3 4 5 This option only will be visible in case of having enabled Flaps on the contrary this section will appear as Not Available Speed Last Before Restart Automatic 1 2 3 4 5 Setpoint disabled...

Page 24: ...s ETS PARAMETRISATION After enabling this function see section 2 4 1 a new tab named Scenes will be incorporated to the tab tree It allows setting up different scenes up to 5 consisting each of them i...

Page 25: ...enabled Value No Change Only available if Setpoint parameter remains disabled 10 25 32 Note this setpoint value may be modified by the setpoint limits during runtime 2 4 4 ERROR HANDLING KLIC PA is ca...

Page 26: ...PA and the status will be the previous to the error activation Errors in the A C unit errors reported by the A C unit itself KLIC PA can notify the KNX bus about the reported error code although refer...

Page 27: ...Probe Error 0 No Alarm 1 Alarm 14 20 26 1 Bit I C W DPT_Enable 0 1 Ix Input Lock 0 Unlock 1 Lock 15 21 27 1 Bit C T DPT_Switch 0 1 Ix Short Press 0 Sending of 0 1 Bit C T DPT_Switch 0 1 Ix Short Pres...

Page 28: ...f 0 63 1 Byte C T DPT_SceneControl 0 63 128 191 Ix Short Press Save Scene Sending of 128 191 1 Bit I O C T R W DPT_Switch 0 1 Ix Switch Sensor Edge Sending of 0 or 1 1 Byte C T DPT_Value_1_Ucount 0 25...

Page 29: ...by 100 0x7 Dec by 1 0x8 Stop 0x9 Inc by 100 0xF Inc by 1 Ix Long Press Darker Long Pr Darker Release Stop 4 Bit C T DPT_Control_Dimming 0x0 Stop 0x1 Dec by 100 0x7 Dec by 1 0x8 Stop 0x9 Inc by 100 0x...

Page 30: ...otection Ix Presence State HVAC Auto Comfort Standby Economy Building Protection 39 68 97 1 Bit O C T R DPT_Occupancy 0 1 Ix Presence State Binary Binary Value 1 Bit O C T R DPT_Ack 0 1 Ix Presence Sl...

Page 31: ...2_Count 32768 32767 DPT_Value_Temp 273 00 670760 00 185 186 187 188 189 190 191 192 4 Bytes I C W DPT_Value_4_Count 2147483648 2147483647 LF 4 Byte Data Entry x 4 Byte Data Entry 193 194 195 196 197 1...

Page 32: ...I C W DPT_Scaling 0 100 AC Speed Percentage Control 0 Automatic 0 4 33 3 S1 33 8 66 6 S2 67 1 100 S3 215 1 Byte O C T R DPT_Scaling 0 100 AC Speed Percentage Control Status Automatic 0 S1 33 3 S2 66 7...

Page 33: ...c Off Delay 0 3600 s 0 Disabled 229 2 Bytes O C T R DPT_Value_Temp 273 00 670760 00 AC Reference Temperature Status Effective Control Temperature C 230 2 Bytes I C W DPT_Value_Temp 273 00 670760 00 AC...

Page 34: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: