KLIC-SG vT
Technical Support:
19
Filter
[
disabled
/enabled
]: enables 1-
Bit objects “
[AC] Filter (Status)
” and
“
[AC] Filter: Reset
”. “
[AC] Filter (Status)
” will send to the bus KNX the value
“1” to indicate that the filter needs to be cleaned. Once the filter is cleaned, the
alarm has to be reset through the object “
[AC] Filter: Reset
” sending the value
“0” or “1”.
IONIZER
Figure 17.
A/C Gateway. Configuration. Ionizer.
Ionizer
[
disabled
/enabled
]: enables the object
“[AC] Ionizer”
y
“[AC] Ionizer
(Status)”
, to activate the air purification mode.
2.2.2
FAN
In the “Fan” tab, KLIC-SG vT allows advanced configuration of the fan functionality. The
following features are displayed:
360 CST
: allows configuration for 360 cassette unit, enabling custom objects
and configurations for this type of IDU. See section 2.2.3 and 2.2.4.
Step Control (1 bit):
allows to increase
(value “1”) or decrease (value “0”) the
current speed level sequentially.
Fan Speeds
2
: allows 3 or 4 ventilation levels, depending on the A/C unit model.
Individual Object for Automatic Mode
: allows enable or disable automatic
fan mode with a 1-bit object.
Individual Object for Fan Stop Indication
: allows to know if the IDU is in a
protection stop with a 1-bit object.
2
This option is only available if
360
CST is not selected, in which case this parameter will
not appear.