KLIC-SG vT
Technical Support:
32
15
1 Byte
O
C R - T -
DPT_Scaling
0% - 100%
[AC] Fan: Percentage Control (Status)
Auto = 0%; S1 = 25,1%; S2 =
50,2%; S3 = 75,3%; S4 = 100%
1 Byte
O
C R - T -
DPT_Scaling
0% - 100%
[AC] Fan: Percentage Control (Status)
Auto = 0%; S1 = 33.33%; S2 =
66.67%; S3 = 100%
16
1 Bit
I
C - W - -
DPT_Enable
0/1
[AC] Fan: Automatic
0 = Automatic On; 1 = Automatic Off
(Speed 1)
1 Bit
I
C - W - -
DPT_Enable
0/1
[AC] Fan: Automatic
0 = Automatic Off (Speed 1); 1 =
Automatic On
17
1 Bit
O
C R - T -
DPT_Enable
0/1
[AC] Fan: Automatic (Status)
0 = Automatic On; 1 = Automatic Off
1 Bit
O
C R - T -
DPT_Enable
0/1
[AC] Fan: Automatic (Status)
0 = Automatic Off; 1 = Automatic On
18
1 Bit
I
C - W - -
DPT_Step
0/1
[AC] Fan: Step Control
0 = Down; 1 = Up
19
1 Bit
O
C R - T -
DPT_Bool
0/1
[AC] Fan: Protection Stop
0 = Normal Operation; 1 = Stop
Protection Activated
1 Bit
O
C R - T -
DPT_Bool
0/1
[AC] Fan: Protection Stop
0 = Stop Protection Activated; 1 =
Normal Operation
20
1 Byte
I
C - W - -
1.xxx
0/1
[AC] 360 CST Air Flow
0 = Spot; 1 = Mid; 2 = Wide; 3 =
Swing
21
1 Byte
O
C R - T -
1.xxx
0/1
[AC] 360 CST Air Flow (Status)
0 = Spot; 1 = Mid; 2 = Wide; 3 =
Swing
22
1 Bit
I
C - W - -
DPT_Switch
0/1
[AC] Horizontal Flaps: Swing
0 = Swing Off; 1 = Swing On
1 Bit
I
C - W - -
DPT_Switch
0/1
[AC] Horizontal Flaps: Swing
0 = Swing On; 1 = Swing Off
23
1 Bit
O
C R - T -
DPT_Switch
0/1
[AC] Horizontal Flaps: Swing (Status)
0 = Swing Off; 1 = Swing On
1 Bit
O
C R - T -
DPT_Switch
0/1
[AC] Horizontal Flaps: Swing (Status)
0 = Swing On; 1 = Swing Off
24
1 Bit
I
C - W - -
DPT_Switch
0/1
[AC] Vertical Flaps: Swing
0 = Swing Off; 1 = Swing On
1 Bit
I
C - W - -
DPT_Switch
0/1
[AC] Vertical Flaps: Swing
0 = Swing On; 1 = Swing Off
25
1 Bit
O
C R - T -
DPT_Switch
0/1
[AC] Vertical Flaps: Swing (Status)
0 = Swing Off; 1 = Swing On
1 Bit
O
C R - T -
DPT_Switch
0/1
[AC] Vertical Flaps: Swing (Status)
0 = Swing On; 1 = Swing Off
26
2 Bytes
I
C - W - -
DPT_Value_Temp
-273.00º - 670433.28º
[AC] External Reference Temperature
[0 ... 70] ºC
27
2 Bytes
O
C R - T -
DPT_Value_Temp
-273.00º - 670433.28º
[AC] AC Unit Mesaured Temperature
Temperature from the internal sensor
(ºC)
28
1 Bit
I
C - W - -
DPT_Switch
0/1
[AC] Automatic Off
0 = Deactivate; 1 = Activate
1 Bit
I
C - W - -
DPT_Switch
0/1
[AC] Automatic Off
0 = Activate; 1 = Deactivate
29
1 Bit
O
C R - T -
DPT_Switch
0/1
[AC] Automatic Off (Status)
0 = Deactivated; 1 = Activated
1 Bit
O
C R - T -
DPT_Switch
0/1
[AC] Automatic Off (Status)
0 = Activated; 1 = Deactivated
30
2 Bytes
I
C - W - -
DPT_TimePeriodSec
0 - 65535
[AC] Automatic Off: Delay
[0...3600] s (0 = Disabled)
31
4 Bytes
I/O
C R W T -
DPT_LongDeltaTimeSec
-2147483648 - 2147483647
[AC] Operating Time (s)
Operation time in seconds
32
2 Bytes
I/O
C R W T -
DPT_TimePeriodHrs
0 - 65535
[AC] Operating Time (h)
Operation time in hours
33
1 Bit
O
C R - T -
DPT_Alarm
0/1
[AC] Internal Error: Communication
Unable to Set AC Communication
34
1 Bit
O
C R - T -
DPT_Alarm
0/1
[AC] Internal Error: Wrong
Acknowledgement
Acknowledgement Received with
Errors