background image

 

 

 

MAXinBOX 24

 

http://www.zennio.com

 

                 

Technical Support:

 

http://support.zennio.com

 

 

10 

2.3

 

MANUAL CONTROL 

MAXinBOX  24  allows  manually  switching  the  state  of  its  output  relays  through  the 

respective  pushbuttons  on  the  top  of  the  device.  A  specific  pushbutton  is  therefore 

available per output. 

Manual  operation  can  be  done  in  two  different  ways,  named  as 

Test  On  mode 

(for 

testing  purposes  during  the  configuration  of  the  device)  and 

Test  Off  mode 

(for  a 

normal  use,  anytime).  Whether  both,  only  one,  or  none  of  these  modes  should  be 

accessible  needs  to  be  parameterised  in  ETS.  Moreover,  it  is  possible  to  enable  a 

specific binary object for locking and unlocking the manual control in runtime.

 

Notes

:  

 

The Test Off mode will be active (unless it has been disabled by parameter) 

after  a  download  or  a  reset  with  no  need  of  a  specific  activation 

–  the 

pushbuttons will respond to user presses from the start.  

 

On  the  contrary,  switching  to  the  Test  On  mode  (unless  disabled  by 

parameter)  needs  to  be  done  by  long-pressing  the  Prog/Test  button  (for  at 

least  three  seconds),  until  the  LED  is  no  longer  red  and  turns  yellow.  From 

that moment, once the button is released, the LED light will  remain green to 

confirm that the device has switched from the Test Off mode to the Test On 

mode.  After  that,  an  additional  press  will  turn  the  LED  yellow  and  then  off, 

once the button is released. This way, the device leaves  the Test On mode. 

Note that it will also leave this mode if a bus power failure takes place

Test Off Mode 

Under  the  Test  Off  Mode,  the  outputs  can  be  controlled  through  both  their 

communication objects and the actual pushbuttons located on the top of the device.  

When one of these buttons is pressed, the output will behave as if an order had been 

received  through the  corresponding  communication  object,  depending  on  whether  the 

output is configured as either an individual output, as a shutter channel or as a fan coil. 

 

Individual output

: a

 

simple press (short or long) will make the output switch 

its  on-off  state,  which  will  be  reported  to  the  KNX  bus  through  the 

Summary of Contents for MAXinBOX 24 ZIO-MB24

Page 1: ...MAXinBOX 24 Multifunction Actuator with 24 Outputs ZIO MB24 USER MANUAL Application programme version 1 1 User manual edition 1 1 _a www zennio com...

Page 2: ...CONTENTS Contents 2 Document Updates 3 1 Introduction 4 1 1 MAXinBOX 24 4 1 2 Installation 5 1 3 Start Up and Power Loss 6 2 Configuration 7 2 1 General 7 2 2 Outputs 9 2 3 Manual Control 10 2 4 Logi...

Page 3: ...MAXinBOX 24 http www zennio com Technical Support http support zennio com 3 DOCUMENT UPDATES Version Changes Page s 1 1_a Changes in the application program Parameters reorganization...

Page 4: ...thout slats Up to 24 individual ON OFF outputs Up to 6 two pipe fan coil modules where both the fan speed control and the valve control are performed through relays A combination of the above 30 custo...

Page 5: ...the associated LED 6 light in red Note if this button is held while plugging the device into the KNX bus the device will enter into safe mode In such case the LED will blink in red every 0 5 seconds O...

Page 6: ...t whether the output channels should switch to a particular state and whether the device should send certain objects to the bus after the power recovery Please consult the next sections of this docume...

Page 7: ...lity Figure 2 General screen The Manual Control function is enabled by default Once activated Inputs Outputs Logic Functions and Manual Control bring additional tabs to the menu on the left On the oth...

Page 8: ...Object to Send 1 that will be sent periodically with a value of 1 to notify that the device is still working still alive Figure 4 Heartbeat Periodical Alive Notification Note The first sending after...

Page 9: ...uped into two output channels which themselves are grouped into two channel or four output blocks Therefore it is possible to configure up to 6 fan coil modules or up to 12 shutter channels or up to 2...

Page 10: ...est On mode unless disabled by parameter needs to be done by long pressing the Prog Test button for at least three seconds until the LED is no longer red and turns yellow From that moment once the but...

Page 11: ...he status objects will be sent to the bus when corresponding Fan Coil module the behaviour will depend on whether a fan labelled or a valve labelled button is pressed Fan a short or long press will sw...

Page 12: ...l recover the values they had prior to entering Test On As the device is never aware of the actual position of the shutter as the shutter drive does not provide any feedback these values may not show...

Page 13: ...ck enabled disabled unless the above parameter has been Disabled the Lock Manual Control parameter provides an optional procedure for locking the manual control in runtime When this checkbox is enable...

Page 14: ...cution of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after exec...

Page 15: ...ending for that output channel module such temporisation will be interrupted and only the delay and the action of the new scene will be executed ETS PARAMETERISATION Prior to setting the scene tempori...

Page 16: ...ure 7 Configuration of Scene Temporization Therefore parameter Scene m Z Delay 0 3600 s 0 1440 min 0 24 h defines the delay that will be applied to the action defined in Z for the execution of scene m...

Page 17: ...C T DPT_Trigger 0 1 Heartbeat Object to Send 1 Sending of 1 Periodically 5 16 27 38 49 60 71 82 93 104 115 126 137 148 159 170 181 192 203 214 225 236 247 258 1 Byte I C W DPT_SceneControl 0 63 128 19...

Page 18: ...4 25 36 47 58 69 80 91 102 113 124 135 146 157 168 179 190 201 212 223 234 245 256 267 4 Bytes I O C T R W DPT_LongDeltaTimeSec 0 2147483647 Ox Operating Time s Time in Seconds 15 26 37 48 59 70 81 92...

Page 19: ...t Direction Status 0 Upward 1 Downward 281 309 337 365 393 421 449 477 505 533 561 589 1 Bit I C W DPT_Switch 0 1 Cx Auto On Off 0 On 1 Off 1 Bit I C W DPT_Switch 0 1 Cx Auto On Off 0 Off 1 On 282 310...

Page 20: ...rsed 0 Lower 1 Raise 294 322 350 378 406 434 462 490 518 546 574 602 1 Bit I C W DPT_Ack 0 1 Cx Direct Positioning 1 0 No Action 1 Go to Position 295 323 351 379 407 435 463 491 519 547 575 603 1 Bit...

Page 21: ...DPT_Value_1_Ucount 0 255 FCx Manual Fan Enumeration Control 0 S0 1 S1 2 S2 1 Byte I C W U DPT_Value_1_Ucount 0 255 FCx Manual Fan Enumeration Control 0 S0 1 S1 623 655 687 719 751 783 1 Byte O C T R...

Page 22: ...Bit O C T R DPT_Switch 0 1 FCx Valve Anti Seize Protection Status 0 Not Active 1 Active 635 667 699 731 763 795 1 Bit O C T R DPT_Bool 0 1 FCx Control Value Error 0 No Error 1 Error 636 668 700 732 7...

Page 23: ...l 0 1 LF Function x Result 1 Bit Boolean 1 Byte O C T R DPT_Value_1_Ucount 0 255 LF Function x Result 1 Byte Unsigned 2 Bytes O C T R DPT_Value_2_Ucount 0 65535 LF Function x Result 2 Byte Unsigned 4...

Page 24: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: