Pressing this button pops up a set of controls to let the user set the current hour
(0-23), minutes, day, month and year.
Figure 6
Time Set Control.
Notes
:
➢
Z41 Pro / Lite incorporate an internal clock powered by a battery (see
section 1.3). Therefore, time/date is not lost after downloads or reboots.
➢
Z41 COM has no battery, so it is recommended to enable the NTP
functionality (see section 3.2.14) or to obtain the date and hour externally,
through the bus.
➢
In Z41 COM, having the date and time updated is very important, so that the
data of the call log entries of the video intercom are reliable. This is
particularly important when there are several Z41 COM synchronized in the
installation. It is recommended that all of the Z41 obtain the date and hour
from the same source.
Device
: button that provides access to a set of device-specific controls, such as
the programming button or the reset button. For further details please refer to
section 2.3.1.
Program Configuration
(only in Z41 Pro and Z41 Lite): button that provides
access to the program information window, which shows the current version of
the application program and the individual address. For further details please
refer to section 2.3.2.
Note
:
In Z41 COM, the information of “Program Configuration” will be shown in
the “Device” window.