INTRODUCTION 

Products

 Z41

,

 Z41 Pro

 and 

Z41 Lite

 incorporate 

two separate

 

microcontrollers

, one 

of  which focuses on interfacing with the KNX bus and on running the application 

program itself, while the second one is dedicated to running  the firmware that 

implements the operating system and the management of the peripherals.  

Therefore, updating Z41, Z41 Lite and Z41 Pro may consist in two phases: 

  Downloading the new application program (from ETS), 

  Downloading the new firmware. 

Two alternative methods are provided for the latter:  

  Downloading the firmware to Z41, Z41 Lite or Z41 Pro  through a flash 

memory drive connected to its 

mini-USB

 

port 

by means of a male mini-USB 

to female USB adapter (ref. ZN1AC-UPUSB). 

  Downloading the firmware to Z41 or Z41 Pro through the local network from a 

PC running the Windows operating system, by means of the 

Ethernet

 

adapter (see the Z41 user manual) bundled with the original packaging of the 

device. 

This option is only available for Z41  and

 

Z41 Pro

, since product 

Z41 Lite does not incorporate an Ethernet interface. 

The next sections explain how to perform the firmware update for each of the two 

alternate procedures,  including the possible events that may take place during the 

process, together with the suggested solutions. 

Important

if  successive  restarts take place within the first two minutes of operation 

after a firmware update (via USB or via Ethernet), the device  may  consider  that the 

new firmware is corrupt and therefore remain  in the status screen  to allow a new 

firmware  update. Please avoid  bus / power interruptions until the new firmware has 

been running for at least two minutes, as they may lead to the above situation (in such 

case, please disconnect and connect Z41 once more to load  the firmware again, and 

ensure that there are no further interruptions for at least two minutes)

 

 

Summary of Contents for Z41

Page 1: ...Z41 Z41 Lite Z41 Pro Firmware Update via the USB Ethernet interfaces DOCUMENTATION Document version e www zennio com...

Page 2: ...c Important note about bus power failures within the first two minutes after a firmware update Self reconnection to network server with no need of a reboot 9 Possibility of enabling disabling the fir...

Page 3: ...rt http support zennio com 3 CONTENTS Document Updates 2 Contents 3 1 Introduction 4 2 Update via USB 5 2 1 Step by Step Process 5 2 2 Troubleshooting 7 3 Update via Ethernet 9 3 1 Step by Step Proces...

Page 4: ...work from a PC running the Windows operating system by means of the Ethernet adapter see the Z41 user manual bundled with the original packaging of the device This option is only available for Z41 and...

Page 5: ...r to section 3 1 1 and to the user manual of Z41 Z41 Pro or Z41 Lite for further detail These are the steps 1 Download from http www zennio com the ZIP file with the firmware corresponding to the desi...

Page 6: ...ne whether its version differs from that already installed if any If both versions are the same no update process will take place Important any firmware version newer or not can be downloaded to Z41 Z...

Page 7: ...ve or try with another The file system in the USB memory is not FAT32 Format the USB memory to the FAT32 file system More than one partition co exist in the USB drive and the pak file has not been fou...

Page 8: ...the application program version that corresponds to the firmware version or install a firmware that matches the current application program The update process was interrupted bus power failure unexpe...

Page 9: ...implemented for example in the network router that dynamically and automatically assigns IP addresses to any new devices joining the network Versions 1 x and 2 x of the Z41 application program only tr...

Page 10: ...where X may depend on the downloaded version 4 The installer will copy the required files to the PC and will add to the Start menu a direct access to the Z41 Update tool Note the PC must have the JAV...

Page 11: ...the Z41 or Z41 Pro user manuals and the individual address it was assigned in the KNX topology On the other hand In case of multiple network interfaces installed on the PC button will let the user ac...

Page 12: ...is currently in working mode Blue bar the device is in the Update mode the Status page is shown on the screen instead of the user interface Important any firmware version newer or not can be downloade...

Page 13: ...box is active 12 During the process the device being updated will show a progress bar At the end of the update the bar will disappear and the device will boot normally unless the application program c...

Page 14: ...if a new password is set by means of an additional parameter download from ETS important it is necessary to import into ETS the same version of the application program that may be running on the devic...

Page 15: ...Z41 Update tool does not find the device after performing a device search Z41 or the PC are not connected to a wired Ethernet network Connect the PC and Z41 to the wired Ethernet network Z41 is not be...

Page 16: ...ogram downloaded via ETS Download from ETS the application program version that corresponds to the firmware version or install a firmware that matches the current application program An old version of...

Page 17: ...d us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 Fax 34 925 337 310 www zennio com inf...

Reviews: