MUGL
Page 29 of 38
rev. 18 November 2009
12.3 Preliminary operations
The first things to do in the initial mask is to enter the “COM” number on which the
converter or the converters are connected.
Click on “porta COM” and select the appropriate address, if not present click on
“refresh”.
The “Baud Rate” for this equipment must be 9600.
The Timeout is the maximum waiting time for the acknowledgment by the load that a
program command has been accepted. After which a serial communication error is
generated.
Once these operations are finished, the serial communication can be activated pressing
the proper button (the green light means activation ok); eventual communication errors
can be reset with the appropriate button.
12.4 identification of FVC connected
A this point the program must identify the converters.
Write in the window at the bottom left the starting address for the search and click on
“Cerca”. In this way the program will begin the identification of all converters connected
and list them in the window. Once all converters are recognized it’s possible to stop the
search with the button "Stop" otherwise automatically goes up to 32.
12.5 Address change
In the section at the top right it’s possible to change the address to the single converter
selecting it in the window, assign the new address and click on “applica”.
Warning
: do not assign the same address to more equipments.
The acquisition of the new address will take place immediately after sending the
command for which the identification of the converters must be repeated.
12.6 Test applications
The program can run 32 applications of command.
To run a command application select the converter in the appropriate window and click
on “lancia”.
12.7 Command mask
After selecting the converter it’s possible to run the application command. The program
first reads the settings of the selected converter and then displays the mask shown below:
the top row shows the name of the converter, the serial number and his serial address