- 16 -
REMOTE BLOWERS (EXTERNAL AND IN-LINE)
CAUTION: To reduce risk of
fi
re and electric shock, install this range hood only with External
Blower Model CBE-1000, and In-Line Blower Model PBN-1000A. Other blowers cannot be
substituited.
INSTALLING THE DUCTWORK: REMOTE BLOWER
NOTE: To reduce the risk of
fi
re, use only metal ductwork.
1. Choose the location where the External Blower or In-Line Blower will be mounted. See
illustrations below for mounting location suggestions and restrictions. Choose the air outlet
location. See Fig. 3.
2. A straight, short duct run using a minimum 6” round duct (10” round duct for the dual
blower) will allow the hood to perform most ef
fi
ciently.
3. Long duct runs, elbows and transitions will reduce the performance of the hood. Use as
few of them as possible. Larger ducting may be required for best performance with long
duct runs.
4. After the External or In-Line Blower has been installed, connect round metal ductwork
and work back towards the hood location. Use duct tape to seal joints between ductwork
sections.
external blower
Attic or crawl space
48” to 72”
above cooking
surface
(blower
housing)
Roof Pitch w/
Flashing & Cap
in-line
blower
(blower
housing)
48” to 72” above
cooking surface
10”
round duct
10”
round
duct
FIG. 2
FIG. 1
FIG. 3
Summary of Contents for ALU-E43
Page 2: ...2...
Page 8: ...8 HOOD SPECIFICATIONS ALU E43...
Page 9: ...9 HOOD SPECIFICATIONS ALU E63...
Page 10: ...10 WIRING DIAGRAM ALU E43...
Page 11: ...11 WIRING DIAGRAM ALU E63...
Page 32: ...32...
Page 33: ...33...
Page 34: ...34...
Page 35: ...35 www zephyronline com HOTTE PER CUISINE Notice d utilisation ALU E43 ALU E63...
Page 41: ...41 SPECIFICATIONS TECHNIQUES ALU E43...
Page 42: ...42 ALU E63 SPECIFICATIONS TECHNIQUES...
Page 43: ...43 SCHEMA ELECTRIQUE ALU E43...
Page 44: ...44 SCHEMA ELECTRIQUE ALU E63...
Page 66: ...66...
Page 67: ...67...
Page 68: ...04308447 5...