background image

www.zephyronline.com

Glide

EGL-E30AS
EGL-E36AS

Guide

d’utilisation,

d’entretien

et

d’inst

a

llation

Use,

Care,

and

Inst

allation

Guide

Model number:
Numéro de modèle: ____________________________________
Número de modelo:

Serial number:
Numéro de série : _____________________________________
Número de serie:

Date of Purchase:
Date d’achat :

_____________________________________

Fecha de compra:

Sales Dealer:
Détaillant:

_____________________________________

Distribuidorr:

READ AND SAVE THESE INSTRUCTIONS

Guía

de

inst

alación,

uso

y

mantenimiento

LISEZ CES INSTRUCTIONS ET  CONSERVEZ-LES
LEAY GUARDE ESTAS INSTRUCCIONES

JAN06.0101

Summary of Contents for Glide EGL-E30AS

Page 1: ...N merodemodelo Serialnumber Num rodes rie _____________________________________ N merodeserie DateofPurchase Dated achat _____________________________________ Fechadecompra SalesDealer D taillant ____...

Page 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Page 3: ...not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 13 Description o...

Page 4: ...t Use This Hood With Any External Solid State Speed Control Device WARNING TOREDUCETHERISKOFARANGETOPGREASEFIRE a Never leave surface units unattended at high settings Boilovers cause smoking and grea...

Page 5: ...local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may...

Page 6: ...5x16 screws x 4 2 to fix the drawer to the bottom of the cabinet 2 to fix the deflector on top of the cabinet ceiling 5x18 screws x 4 upper lower brackets adjusting screws 3 5x9 5 x 4 for definitive...

Page 7: ...6 15 16 1 3 4 30 36 2 3 4 9 13 16 Dimensions and clearances Cut out for venting system and conduit 1 1 4 1 1 4 9 1 4 23 5 16 10 21 3 4 7 1 16 3 3 8 13 16 13 16 Cut out for blower unit housing passage...

Page 8: ...signed to be installed inside a cabinet only Blower unit housing and fixed at the bottom of the cabinet check that the cabinet its bottom the hanging system of the cabinet and the wall where cabinet i...

Page 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Page 10: ...or Cut as indicated 4 Install the vent system before the range hood See Venting methods and Dimensions and clear ance paragraphs Note for Ductless recirculating installations Purchase the Ductless rec...

Page 11: ...side to the blower unit housing Upper bracket lock in place check that each bracket once in position is flush to the front side of the blower unit housing tighten the side fixing screws two per brack...

Page 12: ...nal fixing screw For Ductless recirculating installations Cabinet without ceiling ONLY Install the deflector available as an extra kit on the transition snap into place 11 Connect ducting to transitio...

Page 13: ...the Junction box cover and knockout and install the conduit connector cULUS listed in junction box cover Run 3 wires black white and green according to the National Electrical Code and local codes an...

Page 14: ...14 Description of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp position and nr of lamps may vary 5 Sliding Glass 6 Hood canopy 6 1 2 3 4 5...

Page 15: ...n the flashing LED indicates that the timer has been activated for selected speed Warning The Charcoal filter saturation function is not activated In order to activate the charcoal filter saturation i...

Page 16: ...dishwasher which must be set to a low temperature and a short cycle When washed in a dishwasher the grease filter may discolour slightly but this does not affect its filtering capacity To remove the...

Page 17: ...surrounding area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filt...

Page 18: ...abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connection with eq...

Page 19: ...e com List of Part and Accessories Part Description Part halogen bulb 12V 20 W metal filter Part Description Part Ductless Recirculating Kit charcoal replacement filter Z0B 0013 ZRC 00GL Z0F C063 remo...

Page 20: ...20...

Page 21: ...21 www zephyronline com...

Reviews: