background image

7

WARNING FIRE HAZARD

NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. 
All exhaust must be ducted to the outside, unless using the recirculating option.

Use single wall rigid Metal ductwork only.

Fasten all connections with sheet metal screws and tape all joints w/ certifi ed Silver Tape or Duct Tape.

Some Ducting Options

Installation – 

Ducting Options

side wall cap
w/ gravity damper

Soffit or crawl space

Roof Pitch w/ 

Flashing & Cap

ductless
recirculating

(blower 
housing)

(blower 
housing)

(blower 
housing)

Summary of Contents for Milano Island ZML-M90AG

Page 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number FEB09 0301 Zephyr Corporation Milano Island ZML M90AG AS ZML E42AG AS...

Page 2: ...www zephyronline com...

Page 3: ...lation Sheet 5 Mounting Height Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 10 Ductless Recirculation 11 CONTROLS 12 14 MAINTENANCE Hood and Filter Cleaning 15 Lights 16 TRO...

Page 4: ...NS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not...

Page 5: ...nstallation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all...

Page 6: ...support frame 2 Top duct covers 2 Bottom duct covers 1 Hood body 1 Canopy glass or stainless steel 2 Metal mesh filters 2 50W GU 10 halogen lights 1 6 round damper pre installed MODELS ZML M90AS ZML M...

Page 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Page 8: ...ill loose its performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes fo...

Page 9: ...s using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options...

Page 10: ...ion Hood Specifi cations 23 15 16 35 7 16 or 41 15 16 min ducted 28 min recirc 28 max 38 10 3 8 blower housing 26 10 13 16 elec k o 4 8 1 2 front top of hood blower housing ceiling bracket front of ho...

Page 11: ...ured to the hood with 4 Philips head screws Note If hood is used in ducted mode the charcoal brackets may be discarded Place canopy over blower housing on top of hood and secure to hood body using 4 3...

Page 12: ...om duct covers should rest on top of the hood body FIG E 11 12 Insert the 2 thin trim pieces into left and right seams of bottom duct covers 1 on each side FIG E 12 13 Insert the 2 thick trim pieces i...

Page 13: ...part number above 2 Secure air diverter plate to top support frame FIG F Open sides of air diverter plate should face left and right and align with louver holes on the duct covers Run 6 ducting from...

Page 14: ...shut down after 15 minutes 4 Lights On Dim Off Switch lights on by pressing once press a second time to dim and again to shut off lights 5 Display Window The display window indicates speed levels and...

Page 15: ...age time and indicate by a flashing when charcoal filter replacements are needed C Setting the Filter Change Reminder When off hold for approximately 5 seconds The display will change from exhaust mod...

Page 16: ...30 hours of use Filters can be cleaned by hand with non abrasive soap or in a dishwasher Heavily soiled filters should also be soaked in grease cutting detergent prior to cleaning Metal Filter Clean...

Page 17: ...lled by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Filters should be cleaned after every 30 h...

Page 18: ...y turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately...

Page 19: ...The unit is vibrating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the ho...

Page 20: ...ach Z0B 0020 Metal Filter each 50200011 Optional Accessories Recirculating Kit ZRC 0190 Replacement Charcoal Filter each Z0F C002 Duct Cover Extension Z1C 02ML To order parts visit us online at http s...

Page 21: ...ll labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABL...