After installation, the unit
doesn’t work?

Light works, but motor is
not turning.

The unit is vibrating.

The motor is working,
but the lights are not.

The hood is not venting
out properly.

Filter is vibrating.

After hood has been
installed for a period of
time, it stopped working.

1. The power source is not turned ON.

2. The power line and the cable locking connector is

not connecting properly.

3. The switch board and control board wirings

are disconnected.

4. On the switch board, Black/White wire of White

wire is disconnected.

5. The switch board or control board is defective.

1. The motor is defective, possible seized.

2. The thermally protected system detects if the motor

is too hot to operate and shuts the motor down.

3. Damaged capacitor.

1. The motor is not secure in place.

2. Damaged blower wheel/makes noise.

3. The hood is not secured in place.

1. Defective halogen bulb.

2. The light bulb is loose.

1. T he hood might be hanging too high from the

cook top.

2. The wind from the opened windows or opened

doors in the surrounding area are affecting the
ventilation of the hood.

3. Blocking in the duct opening or ductwork.

4. The direction of duct opening is against the wind.

5. Using the wrong size of ducting.

1. Baffle filter is loose.

1. Control board needs to be reset.

1. Defective control board.

1. Make sure the circuit breaker and the unit’s

power is ON.

2. Check the power connection with the unit is

connected properly.

3. Make sure the wirings between the switch

board and control board are connected properly.

4. Make sure the Black/White wire or White wire
connects properly.

5. Change the switch board or control board.

1. Change the motor.

2. T he motor will function properly after the

thermally protected system cool down.

3. Change the capacitor.

1. Tighten the motor in place.

2. Change the motor.

3. Check the installation of the hood.

1. Change the halogen bulb.

2. Tighten the light bulb.

1. Adjust the distance between the cook top

and the bottom of the hood within 24” and
32” range.

2. Close all the windows and doors to eliminate the

outside wind flow.

3. Remove all the blocking from the duct work or

duct opening.

4. Adjust the duct opening direction.

5. Change the ducting to at least 6” or higher

for the internal blower and 8” or higher for the
external blower.

1. Remove filter and reinstall it or change the

baffle filter.

1. Turn circuit breaker which controls the hood off

for at least 15 minutes.
Turn it back on and this should fix the problem.

1. Replace control b oard.

o

d

o

t

t

a

h

W

e

s

u

a

C

e

u

s

s

I

www.zephyronline.com

Summary of Contents for Okeanito CO K-E36SX

Page 1: ...Okeanito COK E36SX COK E42SX COK E48SX Use Care and Installation Guide MAY07 0101 www zephyronline com Model number Serial number Date of Purchase Sales Dealer Zephyr Corporation ...

Page 2: ...www zephyronline com ...

Page 3: ...ion Sheet Mounting Height and Clearance Ducting Specifications Internal Blower Preparing Hood for External Blower Mounting the Hood FEATURES CONTROLS Controls Overview MAINTENANCE Cleaning Lights TROUBLE SHOOTING LIST OF ACCESSORIES PARTS 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 ...

Page 4: ...c DO NOT USE WATE R includingwet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire departmentis being called 4 You can fight the fire with your back to an exit 5 Based on Kitchen Fire Safety Tips publishe...

Page 5: ... Washers 4 1 2 Screws 5x15mm 4 10mm Washers 1 SMALL HARDWARE PACKET 1 T ool 3 Short Set Screws 4 on 48 Model 1 HARDWARE PACKET EXTERNAL BLOWER KIT 1 8 Collar 1 External Blower Wiring Box with Wires 10 1 2 Self Tapping Screws 10 4mm Internal Diameter Washers NO DUCTING IS PROVIDED EXTERNAL AND INTERNAL BLOWER SOLD SEPARATELY Make sure to remove the protective film off of the hood before installatio...

Page 6: ...und straight 1 Ft x Ft Subtotal column 1 Duct pieces Total Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft 7 Round wall cap with damper 30 Ft x Ft 7 Round 900 elbow 15 Ft x Ft 7 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 Round roof cap 30 Ft x Ft 7 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the to...

Page 7: ...mpute total duct work ALWAYS when possible reduce the number or transitions and turns If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from opening as possible If turns or transitions are required Install as far away from opening and as far apart between 2 as possible Minimum Duct Size Round 6 minimum at 600 cfm Round 10 to 8 minimum at 1000 cfm...

Page 8: ... Blower External Blower WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or DuctTape Some Ducting Options ...

Page 9: ...on Specifications R I H P E Z Y B N G I S E D G N E H C O G O L 19 3 4 19 3 4 10 36 42 48 22 5 8 11 7 8 95 16 5 8 13 3 8 14 1 2 15 5 36 8 42 3 1 2 48 6 9 3 16 6 1 5 O 8 5 16 8 1 4 R 2 3 1 1 4 R 2 3 5 1 8 3 7 1 4 1 ...

Page 10: ...s shown using the provided 1 2 5x15mm screws with washers 3 P osition capacitor box as shown 4 Secure capacitor bo x to hood using the provided 1 2 self tapping screws ATTENTION The following are intructions for installing internal blower model CBI 600 For instructions on preparing for external blower model CBE 1000 please turn to page 10 Before installing verify that motor spins freely ...

Page 11: ... finish installation of capacitor box Refer to Fig A on previous page 7 Attach short capacitor connector to blower connector 8 Attach long capacitor connector to control board connector 9 Use plastic tie to hold wiring together 10 Remove wood block Final view of internal blower install Continue to page 12 for hood installation instructions ...

Page 12: ...ion with external blower model CBE 1000 For instructions on installing internal blower model CBI 600 please turn to page 8 NOTE Please refer to the CBE 1000 manual for external blower mounting instructions 1 Remove screws from internal flange 2 Remove internal flange from hood 3 Position 8 collar as shown 4 Attach 8 collar to hood as shown using provided 1 2 self t apping screws 5 Attach external ...

Page 13: ...nside hood 9 Attach grounding wire from external blower wiring box to grounding screw of the junction box Refer on Fig A in diagram below 10 Final view of external blower preparation Continue to page 12 for hood installation instructions For external blower installation please refer to the manual included with the external blower Ins ta lla tion P repa ring E xterna l B lower ...

Page 14: ...ill and insert provided anchors into the marked holes Cut out inside diameter of the ceiling bracket to fit the 6 or 8 round duct work Attach bracket to ceiling with 2 screws provided 7 Prepare duct work and electrical All Electrical work must be performed by a qualified electrician or person with similiar technical know and background For personal safety remore house fuse or open circuit beaker b...

Page 15: ...re in place by screwing 2 screws with washers throughhood into the wall There are two holes at the bottominside the hood in which to do this 3 Place telescopic duct covers on top of hood and extend top duct cover to the ceiling bracket Attach duct cover to ceiling bracket with the providedscrews 4 Run duct work downto top of motor Attach electrical wiringfrom ceiling to wiringon top of motorhousin...

Page 16: ...rting point to attach the first utensil rail post After the first post is lined up with the hole gently slide the rest of the rail onto the canopy note be careful not to scratch the stainless steel when performing this step this is why there is a starter hole 2 Attach a short set screw into eac h post in order to hold utensil rail onto canopy k c a B t n o r F Set screw ...

Page 17: ...election The 3 speed levels are selected by pressing to decrease and to increase speed level The display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated Press once a dot flashes in the lower right hand side of display indicating the function is on The hood will completely shut down in 15 minutes 4 Lights On ...

Page 18: ...nd with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hours of use Re setting Function Reset the Filter Clean Reminder timer when filters are cleaned and re installed with hood off Press and hold for approx 5 seconds the display will appear hold for approximately 5 seconds un...

Page 19: ...he Metal Filters fitted by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are requiredto be kept clean Filters should be cleaned after every 30 hours of use Use the Filter Clean Reminder function on the controls to determinewhen filters require cleaning Remove filter by sliding towards you and pullingdown Fig 1 Remove and cle...

Page 20: ...the bulb B e careful when releasing retain clip as it is under pressure to hold it in place Replacement halogen bulbs are available at most stores which sell light bulbs Purchase type GU 10 120 V 50W To replace moodlightingbulb remove baffle filter from hood Lift up the metal plate which is inside the hood on the left and right sides It is held on with two philipshead screws Unscrew moodlightingbu...

Page 21: ... against the wind 5 Using the wrong size of ducting 1 Baffle filter is loose 1 Control board needs to be reset 1 Defective control board 1 Make sure the circuit breaker and the unit s power is ON 2 Check the power connection with the unit is connected properly 3 Make sure the wirings between the switch board and control board are connected properly 4 Make sure the Black White wire or White wire co...

Page 22: ...n Part Halogen Bulb GU 10 120V 50W Z0B 0020 Incadescent Bulb T29 127V 40 W Z0B 0003 Internal Blower 600 cfm CBI 600 External Blower 1000 cfm CBE 1000 Duct Cover Extension Kit Z1C 00OK Accessory Description Part List of Parts and Accessories ...

Page 23: ...vices outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Servi...

Reviews: