T
roubleshooting
19
TROUBLESHOOTING PROCEDURES FOR ZPI
Issue
Cause
What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON.
1. Make sure the circuit breaker and the unit’s
power is ON.
2. The power line and the cable locking connector
is not connecting properly.
2. Check the power connection with the unit is
connected properly.
3. Glass canopy is closed.
3. Glass canopy must be open to operate blower
and lights.
4. The switch board and control board wirings are
disconnected.
4. Make sure the wirings between the switch
board and control board are connected
properly.
5. The switch board or control board is defective.
5. Change the switch board or control board.
Light works, but
blower is not
turning.
1. The blower is defective, possible seized.
1. Change the blower.
2. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
2. The blower will function properly after the
thermally protected system cool down.
3. Damaged capacitor.
3. Change the capacitor.
4. The blower wire is not connected.
4. Make sure the blower wire is plugged into the
molex connector.
The unit is
vibrating.
1. The blower is not secure in place.
1. Tighten the blower screws in place.
2. Damaged blower wheel.
2. Change the blower.
3. The hood is not secured in place.
3. Check the installation of the hood.
The blower is
working, but the
lights are not.
1. Defective halogen bulb.
1. Change the halogen bulb.
2. The light bulb is loose.
2. Tighten the light bulb.
3. The light socket wires are disconnected.
3. Check the light socket wire connections.
The hood is
not venting out
properly.
1. The hood might be hanging too high from the
cook top.
1. Adjust the distance between the cook top and
the bottom of the hood within 24” and 32”
range.
2. Wind from opened windows or opened doors in
the surrounding area is affecting the ventilation
of the hood.
2. Close all the windows and doors to eliminate
WKHRXWVLGHZLQGÀRZ
3. Blockage in the duct opening or duct work.
3. Remove all the blocking from the duct work or
duct opening.
4. The direction of duct opening is against the wind.
4. Adjust the duct opening direction.
5. Using the wrong size of ducting.
5. Change the ducting to correct size.
0HWDO¿OWHULV
vibrating.
0HVK¿OWHULVORRVH
&KDQJHWKHPHVK¿OWHU
2. Handle spring clip does not work properly
2. Adjust the handle until the spring clip works